• Title/Summary/Keyword: Nodal Point

Search Result 138, Processing Time 0.034 seconds

A Nodal Probabilistic Production Cost Evaluation at each Load Point using Monte Carlo Simulation Methods (Monte Carlo Simulation을 이용한 각 부하지점별 확률론적 발전비산정)

  • Moon, Seung-Pil;Kim, Hong-Sik;Choi, Hyong-Lim;Choi, Jae-Seok;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.530-532
    • /
    • 2001
  • This paper illustrates a method for evaluating nodal probabilistic production cost using the CMELDC. A new method for constructing CMELDC(the equivalent load duration curves of composite power system) was developed by authors. The CMELDC can be obtained by convolution integral processing between the probability distribution functions of the fictitious generators outage capacity and the load duration curves at each load point. Monte Carlo Methods are applied for the construction of CMELDC on this study. And IEEE-RTS 24 buses model is used as our case study with satisfactory results.

  • PDF

A Three-Dimensional Nodal Diffusion Code Based on the AFEN Methodology (해석함수전개 노달방법에 기초한 3차원 노달확산 코드)

  • Hong, Ser-Gi;Cho, Nam-Zin;Noh, Jae-Man
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.870-876
    • /
    • 1995
  • In this paper, a new three-dimensional nodal diffusion code which is based on the AFEN methodology is described and tested. The method expands the homogeneous flux within a node in ter-ms of eighteen analytic basis functions satisfying the diffusion equation at any point of the node. And the nodal coupling equations are derived such that nodal balance, current continuity and leakage balance within an infinitesimally small box around the edge are satisfied. To verify its accuracy, the code was applied to the well-known static LMW benchmark problem and a small core benchmark problem that has the same material properties as the three-dimensional IAEA benchmark problem and compared with two other codes (QUANDRY, VENTURE). The results show that the code provides good accuracy both in the power distribution and in the effective multiplication factor.

  • PDF

A Study on the Propulsion Shaft Alignment Calculation by the Matrix Method of Three-Moment Theory (삼연모먼트정리의 매트릭스산법에 의한 박용추진축계 배치계산에 관한 연구)

  • 문덕홍;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.20-27
    • /
    • 1981
  • The alignment of propulsion shaft systems by the fair curve method has been developed over the past twenty years and in recent years its basic problems have been almost solved. At the present time, studies on introducing actual conditions are being undertaken. In a fair curve alignment, its aim is to achieve a stable shaft system which will be relatively insensitive to misalignment or the influence of external factors such as thermal variations due to the sunshine, speed change, etc. The key point of fair curve alignment is the calculations of reactions in the straight support and reaction influence numbers. The present authors have developed those calculating method by the matrix method of the three-moment theorem. The fair curve alignment is based on the analysis of propulsion shaft system which is assumed as a continous beam on multiple support points. The propeller shaft is divided into several elements. For each element, the nodal point equation is derived by the three-moment theorem. Reaction of supporting points of straight shaft and reaction influence numbers are calculated by the matrix calculation of each nodal point equation. It has been found that results of calculation for the model shaft agree well with those of experiment which had been measured by the strain gauge method. Results of calculation for the actual propulsion shafting of the steam turbine had been compared also with those of Det norske Vertas.

  • PDF

Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System (분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kim, Jeong-Hyun;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.

Transmission System Expansion Planning by Nodal Delivery Marginal Rate Criterion -II (모선수송전달능력(母線輸送傳達能力) 신뢰도 기준에 의한 송전계통(送電系統)의 광역설계(擴充計劃) -II)

  • Park, Jeong-Je;Shi, Bo;Jeong, Sang-Hun;Choi, Jae-Seok;Mount, Timothy;Thomas, Robert
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.574-575
    • /
    • 2007
  • This paper proposes a method for choosing the best transmission system expansion plan using nodal/bus delivery marginal rate criterion ($BMR_k$) defined newly in this paper. The objective method minimizes a total cost which is an investment budget for constructing new transmission lines subject to the $BMR_k$ which means a nodal deterministic reliability level requirement at specified load point. The proposed method models the transmission system expansion problem as an integer programming problem. It solves for the optimal strategy using a branch and bound method that utilizes a network flow approach and the maximum flow-minimum cut set theorem. Test results on an existing 21-bus system are included in the paper. It demonstrated the suitability of the proposed method for solving the transmission system expansion planning problem in competitive electricity market environment.

  • PDF

APPLICATION OF BACKWARD DIFFERENTIATION FORMULA TO SPATIAL REACTOR KINETICS CALCULATION WITH ADAPTIVE TIME STEP CONTROL

  • Shim, Cheon-Bo;Jung, Yeon-Sang;Yoon, Joo-Il;Joo, Han-Gyu
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.531-546
    • /
    • 2011
  • The backward differentiation formula (BDF) method is applied to a three-dimensional reactor kinetics calculation for efficient yet accurate transient analysis with adaptive time step control. The coarse mesh finite difference (CMFD) formulation is used for an efficient implementation of the BDF method that does not require excessive memory to store old information from previous time steps. An iterative scheme to update the nodal coupling coefficients through higher order local nodal solutions is established in order to make it possible to store only node average fluxes of the previous five time points. An adaptive time step control method is derived using two order solutions, the fifth and the fourth order BDF solutions, which provide an estimate of the solution error at the current time point. The performance of the BDF- and CMFD-based spatial kinetics calculation and the adaptive time step control scheme is examined with the NEACRP control rod ejection and rod withdrawal benchmark problems. The accuracy is first assessed by comparing the BDF-based results with those of the Crank-Nicholson method with an exponential transform. The effectiveness of the adaptive time step control is then assessed in terms of the possible computing time reduction in producing sufficiently accurate solutions that meet the desired solution fidelity.

CLOSURE OPERATIONS AND THE DESCENDING CHAIN CONDITION

  • Vassilev, Janet C.
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.6
    • /
    • pp.1699-1731
    • /
    • 2017
  • In this note, we define and compare some closures which behave somewhat like the radical closure. Using these closures as a starting point allows us to classify all semiprime closures on the nodal curve. Several examples provided show how these closures can differ significantly in the non-Noetherian setting.

EFFICIENT COMPUTATION OF THE ACCELERATION OF THE CONTACT POINT BETWEEN ROTATING SURFACES AND APPLICATION TO CAM-FOLLOWER MECHANISM

  • LEE K.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.115-120
    • /
    • 2006
  • On a rotating contact surface of arbitrary shape, the relative velocity of the contact point sliding between the surfaces is computed with the basic geometries of the rotating surfaces, and the acceleration of the contact point between the contact surfaces is computed by using the relative velocity of the contact point. Thus the equation for the acceleration constraint between the contact surfaces in muitibody dynamics is not coupled with the parameters such as the relative velocity of the contact point. In case of the kinematic analysis, the acceleration of the contact point on any specific instant may also be efficiently computed by the present technique because the whole displacement of a full cycle need not be interpolated. Employing a cam-follower mechanism as a verification model, the acceleration of the contact point computed by the present technique is compared with that computed by differentiating the displacement interpolated with a large number of nodal points.

Analysis of Three-dimensional Cavity flow by using Unstructred grid (비정규 격자를 이용한 3차원 Cavity 유동 해석)

  • Kang, Hyo-Kil;Kim, Moon-Chan;Chun, Ho-Hwan
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.192-197
    • /
    • 2003
  • Three-dimensional cavity flow is analyzed with the code by using unstructured grid. Incompressible Navier-Stokes equations are used as governing equations, and governing equations are discretized by Finite Volume Method. Artificial compressibility method, proposed by Chorin, and developed by Soh, is used for coupling a pressure and a velocity. Cell-centered scheme is adopted in the code, this has the effect of having denser grid than nodal scheme when the same grid is used. Weighted Averaging scheme is used for the value at a nodal point. Cavity flow is analyzed, and this computed results are compared with the results in the research report

  • PDF

Comparison of Interpolation Methods for Reconstructing Pin-wise Power Distribution in Hexagonal Geometry

  • Lee, Hyung-Seok;Yang, Won-Sik
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.303-313
    • /
    • 1999
  • Various interpolation methods have been compared for reconstruction of LMR pin power distributions in hexagonal geometry. Interpolation functions are derived for several combinations of nodal quantities and various sets of basis functions, and tested against fine mesh calculations. The test results indicate that the interpolation functions based on the sixth degree polynomial are quite accurate, yielding maximum interpolation errors in power densities less than 0.5%, and maximum reconstruction errors less than 2% for driver assemblies and less than 4% for blanket assemblies. The main contribution to the total reconstruction error is made tv the nodal solution errors and the comer point flux errors. For the polynomial interpolations, the basis monomial set needs to be selected such that the highest powers of x and y are as close as possible. It is also found that polynomials higher than the seventh degree are not adequate because of the oscillatory behavior.