• Title/Summary/Keyword: No-contact

Search Result 1,641, Processing Time 0.034 seconds

A CLINICAL STUDY ON THE OCCLUSAL CONTACT PATTERN IN CENTRIC AND ECCENTRIC OCCLUSION (중심교합 및 비중심위교합에서의 치아접촉유형에 관한 임상적 연구)

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.22 no.10 s.185
    • /
    • pp.869-877
    • /
    • 1984
  • An objective examination of 123 subjects aged from 19 to 23 was made from a clinical standpoints to determine the natural occurrence in anterior tooth contact in centric occlusion, and tooth contact in protrusive occlusion, left and right lateral excursions, and temporomandibular dysfunction. 1. In centric occlusion, maxillary 6 anterior contact type was frequently observe (30.08%) compared with other types of contact (incisor contact: 19.47%, no contact: 17.70%, canine and incisor contact: 15.04%, canines contact: 12.39%, unilateral canine contact: 5.31%) (P<0.01) 2. In protrusive position (edge to edge bite), maxillary central incisors contact was predominant (86.7%). (P<0.01) 3. In lateral excursion, there was not any significant difference between canine guided occlusion (47.79%) and group function occlusion (total 51.32%, AG:9.29%, PG:13.27%, G:28.76%). 4. Temporomandibular joint dysfunction was observed in 12.4% of 123 subjects.

  • PDF

A Contact Algorithm in the Low Velocity Impact Simulation with SPH

  • Min, Oak-Key;Lee, Jeong-Min;Kim, Kuk-Won;Lee, Sung-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.7
    • /
    • pp.705-714
    • /
    • 2000
  • The formulation of Smoothed Particle Hydrodynamics (SPH) and a shortcoming of traditional SPH in contact simulation are presented. A contact algorithm is proposed to treat contact phenomenon between two objects. We describe the boundary of the objects with non-mass artificial particles and set vectors normal to the contact surface. Contact criterion using non-mass particles is established in this study. In order to verify the contact algorithm, an algorithm is implemented in to an in-house program; elastic wave propagation is an analysed under low velocity axial impact of two rods. The results show that the contact algorithm eliminates the undesirable phenomena at the contact surface; numerical result with the contact algorithm is compared with theoretical one.

  • PDF

Analysis of Suspension State Matrix to Improve L/UL Performance (로드/언로드 성능향상을 위한 서스펜션 상태행렬의 해석)

  • Kim, Ki-Hoon;Lee, Young-Hyun;Park, Kyung-Su;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1272-1275
    • /
    • 2007
  • The HDD (hard disk drive) using Load/Unload (L/UL) technology includes the benefits which are increased areal density, reduced power consumption and improved shock resistance than those of contact-start-stop (CSS). Dynamic L/UL has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. Main design objectives of the L/UL mechanisms are no slider-disk contact or no media damage even with contact during L/UL, and a smooth and short load and unload process. In this paper, we focus on state matrix, pitch static attitude (PSA), roll static attitude (RSA), loading/unloading contour (LC/ULC), impact force and contact. Stability of slider is mainly determined by PSA and RSA. State matrix by PSA and RSA is also important indicator. Therefore we analyze state matrix of SFF HDD suspension through the LC/ULC.

  • PDF

Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor (비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성)

  • Jeon, Hwa-Bong;Yun, Jung-Won;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

The role of domestic tap water in Acanthamoeba contamination in contact lens storage cases in Korea

  • JEONG Hae Jin;YU Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.2 s.134
    • /
    • pp.47-50
    • /
    • 2005
  • A survey was carried out from August to December 2004 in Pusan, Korea to document the presence of free-living amoeba (FLA), including the genus Acanthamoeba, in both contact lens storage cases and domestic tap water. Acanthamoeba was isolated from $5(4.2\%)$ in 120 contact lens storage cases. Four house tap water samples from residents, whose contact lens storage cases had been contaminated by Acanthamoeba, were also found to be contaminated with Acanthamoeba. Therefore, the contamination rate of FLA and Acanthamoeba in domestic tap water was investigated in order to examine the role of domestic tap water in Acanthamoeba contamination of contact lens storage cases. FLA and Acanthamoeba were identified in $97(46.8\%)\;and\;16(7.7\%)$ of the 207 domestic tap water samples, respectively. There were no significant differences between the contamination rates of FLA in tap water according to the filtration plant of origin. No FLA was detected in the tap water directly supplied by the water purification plants. Water storage tanks appear to promote FLA colonization, including Acanthamoeba, in domestic tap water. This increases the risk of Acanthamoeba contamination in contact lens storage cases as well as increasing the risk of Acanthamoeba keratitis.

Contact resistance increment of no-insulation REBCO magnet during a quench

  • Im, Chaemin;Cho, Mincheol;Bang, Jeseok;Kim, Jaemin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.31-35
    • /
    • 2019
  • The lumped-parameter circuit model for a no- insulation (NI) high temperature superconductor (HTS) magnet has been well understood after many experimental and analytic studies over a decade. It successfully explains the non-linear charging behaviors of NI magnets. Yet, recently, multiple groups reported that the post-quench electromechanical behaviors of an NI HTS magnet may not be well explained by the lumped circuit model. The characteristic resistance of an NI magnet is one of the key parameters to characterize the so-called "NI behaviors" of an NI magnet and recently a few groups reported a potential that the characteristic resistance of an NI magnet may substantially vary during a quench. This paper deals with this issue, the increment of contact resistance of the no-insulation (NI) REBCO magnet during a quench and its impact on the post-quench behaviors. A 7 T 78 mm NI REBCO magnet that was previously built by the MIT Francis Bitter Magnet Laboratory was chosen for our simulation to investigate the increment of contact resistance to better duplicate the post-quench coil voltages in the simulation. The simulation results showed that using the contact resistance value measured in the liquid nitrogen test, the magnitude of the current through the coil must be much greater than the critical current. This indicates that the value of the contact resistance should increase sharply after the quench occurs, depending on the lumped circuit model.

Review : Thermal contact problems at cryogenic temperature

  • Jeong, Sangkwon;Park, Changgi
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • This paper addresses technical problems of thermal contact conductance or resistance which inevitably occurs in most cryogenic engineering systems. The main focus of this paper is to examine what kind of physical factors primarily influences the thermal contact resistance and to suggest how it can be minimized. It is a good practical rule that the contact surface must have sub-micron roughness level with no oxide layer and be thinly covered by indium, gold, or Apiezon-N grease for securing sufficient direct contact area. The higher contact pressure, the lower the thermal contact resistance. The general description of this technique has been widely perceived and reasonable engineering results have been achieved in most applications. However, the detailed view of employing these techniques and their relative efficacies to reduce thermal contact resistances need to be thoroughly reviewed. We should consider specific thermal contact conditions, examine the engineering requirements, and execute each method with precautions to fulfil their maximum potentials.

Conditions for Assuming Hertzian Stress for the Contact between a Circular Pin and Hole (원형 핀과 구멍의 접촉에서 헤르츠 응력장 가정을 위한 조건)

  • Kim, Hyung-Kyu
    • Tribology and Lubricants
    • /
    • v.31 no.5
    • /
    • pp.189-194
    • /
    • 2015
  • This paper focuses on the conformal contact problem. A typical example of conformal contact is the contact between a pin and hole. In particular, this paper focuses on the condition for assuming a contact stress field to be a Hertzian pressure profile by using well-known classical solutions associated with Hertzian contact. Persson first developed the conformal contact analysis method around half a century ago, but there have been no significant improvements since then. The present research also adopted this method, but developed new solutions from the viewpoint of application to structural design. The analysis began with a comparison between Persson°Øs conformal contact stress and the Hertzian stress fields. The next step was to check the differences in the normalized stress values of both. This study used the tolerance for the difference in the peak stresses of Persson°Øs solution and the Hertz solution to validate the Hertzian assumption. This gave the range for the difference in radii of the pin and hole when the contact force and mechanical properties of the material are specified. The results showed that, at a tolerance of 5%, the Hertzian assumption is valid if half of the contact angle is less than 35°ý. In addition, the Hertzian assumption holds even for a relatively long contact length, in contrast to the general incomplete contact problem. This paper discusses these results along with other aspects of the application to the design.

Effects of Combination of the Load and the Apparent Area of Contact on Sliding Wear behavior of Mild Steel in a Pin-on-disc Type Apparatus (Pin-on-Disc식 미끄럼마모시험 시 마모 거동에 미치는 접촉면적 및 하중 조합의 영향)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • The effects of contact pressure on the sliding wear behavior of mild steel in a pin-on-disc type apparatus were investigated. Sliding wear tests were conducted with various combinations of the load and apparent area of contact. The wear behavior of mild steel as a function of sliding speed was independent of contact pressure. However, the wear rate at different sliding speeds was influenced by the load regardless of the apparent area of contact. This was attributed to the fact that there may be no difference in the real area of contact for any combination of the load and apparent area of contact.

Microbial Quality and Safety of Fresh-Cut Broccoli with Different Sanitizers and Contact Times

  • Das, Basanta Kumar;Kim, Ji-Gang
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.2
    • /
    • pp.363-369
    • /
    • 2010
  • This study was conducted to investigate the effects of different sanitizers and contact times on storage quality and microbial growth in fresh-cut broccoli. Fresh broccoli samples were cut into small pieces, washed each for 90 s and 180 s in normal tap water (TW), $100\;{\mu}/l$ chlorinated water (CL, pH 7), electrolyzed water (EW, pH 7.2) containing $100\;{\mu}/l$ free chlorine, or $2\;{\mu}/l$ ozonated water ($O_3$). Then, samples were packaged in 30-${\mu}m$ polyethylene bags and stored at $5^{\circ}C$ for 9 days. No significant differences were observed in gas composition and color parameters ($L^*$, $a^*$, $b^*$, and hue angle) among different sanitizers with contact times. No off-odor was detected during the storage. A longer contact time was not effective in reducing microbial population, except with $O_3$ washing. $O_3$ with 90 s was not much effective in reducing microbial population compared with Cl or EW. However, samples washed with $O_3$ for 180 s observed the lowest numbers of total aerobic and coliform plate counts. The result suggested that, a longer contact time of ozone can be used as a potential sanitizer to maintain the microbial quality and safety of fresh-cut broccoli.