• Title/Summary/Keyword: No-Insulation

Search Result 302, Processing Time 0.028 seconds

A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings (공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구)

  • Ham, Jin-Sik
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.

Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated (인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.1-6
    • /
    • 2018
  • This study is to analyze the characteristics of the yellow insulation ring type of the CSST used for tubing when it is artificially deteriorated and damaged by burning. The CSST for tubing consists of a tube, protective coating, nut, yellow insulation ring, packing, and socket. In addition, it is thought that a yellow insulation ring and rubber packing were used to connect the tube and socket in order to improve the airtightness and insulation performance. The result of the verification of the data acquired from the tests in the 95% confidence interval shows that the Anderson-Darling (AD) and P value were analyzed to be 0.945 and 0.015, respectively. This confirms that the test data of the CSST for tubing is reliable. The analysis of the arithmetic mean of the insulation resistance of a CSST showed that the CSST damaged by burning by a torch, and the one damaged by electrical burning, was $16.7k{\Omega}$ (the greatest relatively) and $208{\Omega}$ (the lowest), respectively, while it was $1.72k{\Omega}$ in the case of a normal product. Therefore, the analysis result of the insulation resistance of the CSST collected from the scene of a fire can be utilized to examine the cause of damage by burning. In addition, it was found that when the maximum current of 97 A was applied to the CSST for about 5 s using a Primary Current Injection Test System (PCITS) the protective film and insulation ring of the CSST has no difference from that of a normal product. However, a part of the metal tube was melted.

Analysis on the over current characteristics of metal insulated HTS coil (금속 절연 초전도 코일의 과전류 특성 해석)

  • Cho, Jeonwook;Sim, Kideok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1110-1111
    • /
    • 2015
  • 초전도 코일의 안정성(stability)을 향상시키기 방법으로 초전도 자석의 턴(turn) 사이의 절연을 없애는 무절연 코일(no-insulation coil) 및 금속 테이프를 같이 권선하는 금속절연 코일(metal insulation coil)이 제안되어 활발히 연구되고 있다. 본 논문에서는 고온초전도 코일의 열적, 전기적 메카니즘을 분석하기 위한 FEM 모델을 제시하고, 이를 사용하여 �치 시 고온 초전도 코일의 안정성 향상 정도를 해석한다.

  • PDF

Behaviors of turn-to-turn contact resistance (Rc) of various REBCO CC tapes according to applied contact pressure

  • Jeong, Chanhun;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • No-insulation (NI) pancake magnets are fabricated using Rare earth-Barium-Copper Oxide (REBCO) coated conductor (CC) tapes, which enabled a very compact magnet in the aspects of high critical current density ($J_c$) and high mechanical strength by removing insulation and allowing thinner stabilizer. They have also advantages such as self-quench protection. Therefore, it does not need quench detection and protection that can be very challenging in a high critical temperature ($T_c$) superconducting magnet technology. Recently, it was reported that the NI REBCO CC magnets have some drawbacks of long charging time and high field ramp loss which will be a concern in the operation of cryocooled magnets. These issues are related to the turn-to-turn contact resistivity and can be released by managing it. This is also closely related to the activity of reducing the contact joint resistance in the case of CC joints for long length CC fabrication. Therefore, in this study, the turn-to-turn contact resistance ($R_c$) at the CC contact part of differently stabilized CC tapes was measured. The behaviors of $R_c$ at CC contact parts according to the applied contact pressure were investigated. The range of $R_c$ measured for CC tapes adopted will provide fundamental data for design and fabrication of the CC NI coils.

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

Study on Bubble Behavior with the Simulated Electrode System of High Temperature Superconducting Coils for Electric Power System (전력용 고온초전도 코일 모의전극계에서의 기포거동에 관한 연구)

  • 석복렬;김종구
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2001
  • Bubble behavior is studied with an electrode system which consists of coaxial spiral coil-to-cylindrical electrode with an insulation barrier and spacers and is immersed in liquid nitrogen for simulation of insulation environments in high temperature superconducting(HTS) coils The results show that the bubble behavior Is affected severely by electric field: (1) under low applied voltage bubbles rise by buoyancy, but at higher applied voltage they are trapped in a lower electric field region below the coil electrode, and (2) the trapped bubble flows along the downside of coil electrode if no obstruction is in a groove between coil turns. but it splashes out of the groove after its growing if the obstruction such as spacer-exists.

  • PDF

A study on the sound insulation performance of damping sheet attached to the train wall (철도차량벽체의 차음 성능에 대한 제진시트의 영향 고찰)

  • Seo, Dae-Hoon;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.97-100
    • /
    • 2007
  • This study deals with the sound insulation performance of the damping sheet, which is widely used in a train. The wall of train is assumed to be a plate made of steel and two damping sheets. In case of damping sheet only, the sound transmission loss follows the mass law. If a steel plate is attached to damping sheet, the transmission loss is found to be higher than single of only steel plate, as we can anticipated, about $3{\sim}5$ dB. This is very well known consequence that is because the density of area increases. However, the increase of the transmission loss is not higher than what we can expect by the mass law. That's because the steel is perfectly blocked from the transmission of the air ; There is no defect in that material.

  • PDF

Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen (액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구)

  • Na, J.B.;Ko, T.K.;Kang, H.;Seok, B.Y.;Kim, T.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.