• Title/Summary/Keyword: No load temperature

Search Result 243, Processing Time 0.034 seconds

Performance Evaluation of a $SF_6$ Gas Circuit Breaker with Experimental Investigation (초고압 $SF_6$ 가스 차단기의 실험적 차단성능 평가)

  • Jeong, Y.W.;Park, H.T.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.96-99
    • /
    • 2005
  • In this study, we build system and techniques of evaluating the interruption performance of the GCB with experimental method. We constructed a simplified synthetic test circuit of which ability is up to 245kV, 50kA BTF test. And We composed a model test circuit breaker with puffer assisted self blasting type GCB. With this circuit breaker, we carried out the experiment of no load and SLF90. During the tests, we measured the several factors such as stroke, pressure, arc temperature, the voltage and current near the current zero and dI/dt, dV/dt. Arc conductivity before 200ns before current zero which is one of the indexes of the thermal recovery of a GCB was measured. With these kinds of measurement, we could estimate the performance of a GCB fundamentally. Futhermore these results were used to adjust the arc modeling with CFD(computational fluid dynamics) and we could increase the plausibility of the analytical method.

  • PDF

Calculation of Pollutant Load for Prediction of Pollutant Loads to Watershed (합리적인 유역단위 오염부하량 산정방법 연구)

  • Jang, Jae-Ho;Yoon, Chun-Gyung;Jung, Kwang-Wook;Kim, Hyung-Chul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.534-539
    • /
    • 2005
  • The purpose of this study is the introduction of pollutant loads's estimation into Saemangeum watershed area with M.E.'s guidebook for TMDL and GIS tool. To estimate reliable pollutants loads, it is necessary to think about characteristic of removal, discharge and runoff as time series. In this study, it was calculated for generation loads which be came from pollutant source, discharge loads which be reduced in the treatment facilities and delivery loads which be considered the self purification parameter and delivery distance. To assess the delivery distance handily, it was particularly estimated using Arc-GIS. It was met with good results that delivery loads of BOD, T-N and T-P was reflected to seasonal precipitation. Lastly to verify the estimated pollutant loads, HSPF developed by USEPA was applied to it. It was showed a relativity of observed to simulated data for flow, Temperature, DO, BOD, $NO_3^--N$ TN and TP. Consequantly, this delivery loads can make full use of model input data for prediction of pollutant loads.

  • PDF

Optimization of Honeycomb Spoke in Non-pneumatic Tire (비공기압 타이어에 사용되는 Honeycomb Spoke의 최적화)

  • Lee, Jinwook;Jang, Inhwan;Han, Gyumo
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.204-215
    • /
    • 2017
  • Unlike existing pneumatic tire, NPT(Non-Pneumatic Tire) is a tire replacing air pressure with spokes. NPT has no problem of punk which pneumatic tire has and doesn't need to maintain air pressure. Also it can be used in space where temperature change sharply. In this regard, NPT are attracting attention as next-generation wheels. For optimizing Honeycomb structure, we applied the load to various Honeycomb structure which forms NPT, performed FEM(finite element analysis) using Edison and compared each results.

  • PDF

A Study on Alternative Fuel as Fuel Substitutes in a DI Diesel Engine(II) (Startability and Durability) (디젤기관의 대체연료 이용에 관한 연구(II) (시동성 및 내구성 문제))

  • 오영택;정규조;촌산정
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.48-53
    • /
    • 1988
  • In a previous report, the properties of vegetable oils as diesel fuel substitutes were investigated and the basic load performance of a diesel engine was examined using vegetable oil. The results show that despite of the long term chain hydrocarbon structure and large droplet size due to high viscosity, vegetable oils have good basic performance and exhaust emissions, however they cause serious problems as carbon deposit buildup, they have poor durability, and also poor thermal efficiency. In this paper, the startability and engine durability with long term operation was tested by physical methods for reducing viscosity when vegetable oil was used as compared against diesel fuel. The results obtained in this investigation may be stated as follows; (1) There is no problem in startability when vegetable oil was used as diesel fuel substitutes as far as fuel temperature is higher than 30.deg. C (2) The carbon deposits were most extensive at lower loads and lower engine speeds, and deposit buildup more heavily on the cooler parts of the combustion chamber wall. (3) Blends with 25% diesel fuel and 20v-% ethanol are effective in reducing the carbon deposit buildups. (4) Significant improvement in carbon deposit and piston ring stick can be obtained by heating fuel(200.deg.).

  • PDF

Piezoelectric Characteristics of Pb(Mnsub 1/3Nb 23)Osub 3-Pb(Zr, Ti)Osub 3 Ceramics with $CeO_2$ Impurity for the Piezoelectric Transformer (Cerium Oxide 첨가에 따른 압전트랜스포머용 $Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3$ 세라믹의 압전특성)

  • Ryu, Ju-Hyeon;Seo, Seong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.611-615
    • /
    • 1999
  • Piezoelectric properties of PMN-PZT ceramics with $CeO_2$ impurity were investigated. Mechanical quality factor, $Q_m$ of 1792, 1285 and the electromechanical coupling coefficient, $k_p$ of 0.52, 0.54 were obtained from the specimen with 0.25 and 0.5 mole % $CeO_2$ respectively. Curie temperature was decreased with the addition of $CeO_2$ while the electric coercive field was proportional to the amount of impurity. Based on the system ceramics with 0.5 mole % cerium oxide, a Rosen type piezoelectric transformer was fabricated and tested. Voltage step-up ratios of 230 and 13 were obtained from the transformer at no load and $100 k\Omega$ resistance, respectively. Experimental results showed a potential of the transformer for the practical use coupled with the expected strength increase by the grain size refinement.

  • PDF

Electrical Characteristics of the High Power Piezoelectric transformer Using PSN-PZT system ceramics (PSN-PZT계 세라믹스를 이용한 고출력 압전 트랜스포머의 전기적 특성)

  • 이용우;류주현;윤광희;정회승;서성재;김종선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.286-293
    • /
    • 2000
  • In this paper we investigated the structural dielectric and piezoelectric properties of 0.03Pb(Sb$\_$1/2//Nb$\_$1/2/)-0.97Pb(Zr$\_$0.495//Ti$\_$0.505/)O$_3$+0.5 wt% excess PbO + wt% MnO(X=0, 0.1, 0.3, 0.5, 0.7) ceramics to develop the high-power piezoelectric transformer. The piezoelectric transformers with dimension of 27.5$\times$27.5$\times$2.5[mm$^3$]were fabricated and their electrical properties were measured. Maxima of piezoelectric properties such as electro-mechanical coupling factor of 0.534 and mechanical quality factor of 1487 were obtained for the PSN-PZT with 0.3wt% MnO. voltage step-up ratios of piezoelectric transformers at 500[Ω]and no load were 0.78, 12.82, respectively. The maximum efficiency of piezoelectric transformer was 98.6% at 800[Ω]. While the 14W fluorescent lamp were driven by the piezoelectric transformer for more than 20[min], increment of temperature in the piezoelectric transformer was 7[$\^{C}$].

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • Pak, Ee-Tong;Jeong, Un-Chul
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.39-47
    • /
    • 1996
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. And arrangement of heating pad play an important role in thermal flow and thermal storage efficiency. In this experiments, number of heating pad is ranged from three, five and nine, and when there is no change on number of heating pad, arrangements are two types of concentration-type and dispersion-type. Strong entrainment take place in the case of concentration-type of heating pad, and rapid temperature rise(${\Delta}{\doteqdot}1.6{\sim}3.2^{\circ}C$) in the tank is obtainable on the concentration-type than dispersion-type. In the constant number of heating pad, the concentration-type has the higher efficiency with about $5{\sim}6%$ than the dispersion-type Therefore, concentration-type of heating pad is an efficient design in constant number of heating pad.

  • PDF

An experimental study on the evaluation of abrasion resistance for concrete surface coating materials by cruising vehicle (차량 주행에 따른 콘크리트용 바닥 마감재의 마모저항성 평가방법)

  • Choi, Eun-Su;Kim, Young-Kun;Seo, Sang-Kyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.849-852
    • /
    • 2008
  • In the wheel tracking test to evaluate abrasion resistance for concrete surface coating materials applied parking lot, weight of the wheel, test temperature, scattered sand amount, wheel speed, etc. various test condition is used for reliable evaluating the abrasion resistance performance of surface coating materials and the results depends on the test condition. In this paper, we carried experimental study as following on abrasion resistance with 2kinds of different environmental conditions. - Commons : real car tire with 300kg of load, 5km/h of speed, 80,000 cycle. - Control A : no other deterioration condition - Control B : scattering 1.0g of sand per every 30rounds from 1m height.

  • PDF

Evaluation on Creep Life Prediction of Aircraft Gas Turbine Material by AE (음향방출법에 의한 항공기용 가스터빈 재료의 크리프 수명예측 평가)

  • Kong, Y.S.;Yoon, H.K.;Oh, S.K.
    • Journal of Power System Engineering
    • /
    • v.6 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • There has been no report on the life prediction for gas turbine materials at high temperatures based on the creep properties and their relationship with the AE(acoustic emission) properties as a means of real-time non-destructive testing. One of the important issues is thus to develop a reliable method of evaluating creep properties by the AE technique. In this paper, the real-time evaluation of high temperature creep time and AE cumulative counts for nickel-based superalloy Udimet 720 was performed on round-bar type specimens under pure load at the temperatures of 811, 922 and 977K. The total AE cumulative counts until the starting point of secondary creep($N_1$) and that of tertiary creep($N_2$) have quantitative relationship with the tertiary creep time and the rupture time. It is thus possible to construct the life prediction system based on creep and the prevention system of tertiary creep by using AE technique.

  • PDF

Behaviour of high strength concrete-filled short steel tubes under sustained loading

  • Younas, Saad;Li, Dongxu;Hamed, Ehab;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.39 no.2
    • /
    • pp.159-170
    • /
    • 2021
  • Concrete filled steel tubes (CFSTs) are extensively used in a variety of structures due to their structural and economic advantages over other types of structures. Considerable research has been conducted with regards to their short-term behaviour, and very limited studies have focused on their long-term behaviour. In this study, a series of tests were carried out on high strength squat (short) CFSTs and concrete cylinders under controlled conditions of temperature and humidity to better understand their time dependent behaviour. A number of parameters were investigated including the influence of steel and concrete bond, confinement, level of sustained load and sizes of specimens. The results revealed that creep strains increased by more than 40% if there was no bonding between steel tube and concrete core. As expected, creep and shrinkage of concrete inside a steel tube were significantly less than those developed in exposed concrete. At the end of a creep period of six months, all the specimens were tested to failure to observe the influence of sustained loads on the ultimate strength. It was found that creep does not have a major effect on the strength of short CFSTs in the specific experimental study conducted here, which was less than 2.5%.