• 제목/요약/키워드: No load temperature

검색결과 241건 처리시간 0.022초

COMBUSTION STABILITY OF DIESEL-FUELED HCCI

  • Shi, L.;Deng, K.;Cui, Y.
    • International Journal of Automotive Technology
    • /
    • 제8권4호
    • /
    • pp.395-402
    • /
    • 2007
  • Homogeneous Charge Compression Ignition (HCCI) shows great potential for low $NO_x$ emission but is hampered by the problem of no direct method to control the combustion process. Therefore, HCCI combustion becomes unstable easily, especially at lower and higher engine load. This paper presents a method to achieve diesel-fueled HCCI combustion, which involves directly injecting diesel fuel into the cylinder before the piston arrives at top dead center in the exhaust stroke and adjusting the valve overlap duration to trap more high temperature residual gas in the cylinder. The combustion stability of diesel-fueled HCCI combustion and the effects of engine load, speed, and valve overlap on it are the main points of investigation. The results show that: diesel-fueled HCCI combustion has two-stage heat release rate (low temperature and high temperature heat release) and very low $NO_x$ emission, combustion stability of the HCCI engine is worse at lower load because of misfire and at higher load because of knock, the increase in engine speed aids combustion stability at lower load because the heat loss is reduced, and increasing negative valve overlap can increase in-cylinder temperature which aids combustion stability at lower load but harms it at higher load.

2단 Gifford-McMahon 극저온냉동기의 특성실험 (An Experimental Study of the 2-stage Gifford-McMahon Cryorefrigerator)

  • 박성제;고득용;유창종;김의준;최헌오
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.198-206
    • /
    • 1993
  • Experimental results of two stage Gifford-McMahon cryorefrigerator are described. In-prototype experiments, drive mechanism is Scotch Yoke type driven by stepping motor, copper meshes and lead balls are used for regenerator's materials in the first stage and the second stage, respectively. To find optimal conditions of the cryopump, no load temperature and refrigeration capacity according to the variation of cycle frequency and operating pressure are measured, and the cool down and load characteristics at particular cycle frequencies are presented. In general, as the cycle frequency is lowered, no load temperature is dropped but refrigeration capacity is diminished. As the representative result, in a case that the cycle frequency is 70rpm and steady state pressure is 14 atm, no load temperature of second stage is lowered to 10.5K in 55 minuters, and in this situation the refrigeration capacity of the first stage is 42W at 80K, that of the second stage is 11 W at 20K.

  • PDF

77K Inertance tube 맥동관 극저온 냉동기에 관한 연구 (An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler)

  • 박성제;고득용;김효봉
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

부하변동이 큰 화장시설 SCR 공정에서 NOx/N2O 및 NH3 동시 저감 특성 연구 (The Reaction Characteristics of NOx/N2O and NH3 in Crematory Facility SCR Process with Load Variation)

  • 박풍모;이하영;여상구;윤재랑;동종인
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.605-615
    • /
    • 2017
  • Efficient simultaneous reduction conditions for $NO_x$ and $NH_3$-slip was investigated in SCR (Selective Catalytic Reduction) process with load variation by applying dual catalysts (SCR catalyst, $NH_3$ decomposition catalyst) system. $N_2O$ formation characteristics were analyzed to look into possible undesirable reaction pathways. In the experiments of catalyst characteristics, various operational variables were tested for the combined catalytic system, such as $NH_3/NO_x$ ratio, temperature, oxygen concentration and $H_2O$. The reaction characteristics of $NO_x$, $NH_3$ and $N_2O$ were analyzed and optimal conditions could be evaluated for the combustion facility with varied load. In terms of $NO_x/NH_3$ simultaneous reduction and $N_2O$ formation suppression, optimal condition was considered NSR 1.2 and temperature $300^{\circ}C$. At this operational condition, $NO_x$ conversion was 98%, $NH_3$ reduction efficiency was 95%, generated $N_2O$ concentration 9.5 ppm with inlet $NO_x$ concentration of 100 ppm. In $NH_3-SCR$ process with $NH_3$ decomposition catalyst, $NO_x$ and $NH_3$ can be considered to be reduced simultaneously at limited conditions. The results of this study may be utilized as basic data at facilities requiring simultaneous $NO_x$ and $NH_3$ reduction for facilities with load variation.

스월 예혼합 버너의 연소 특성에 관한 실험적 연구 (Experimental Study on Combustion Characteristics of a Swirl-stabilized Conical Burner)

  • 김구;조주형;이동석;김한;손채훈;이상민;김민국;안국영
    • 한국연소학회지
    • /
    • 제19권3호
    • /
    • pp.1-7
    • /
    • 2014
  • Experimental study has been carried out to understand combustion characteristics of a swirl-stabilized premixed gas turbine combustor for power generation. $NO_x$ and CO emissions, extinction limit, pressure loss, and temperature distribution were measured for various operating conditions. Results show that, with increasing inlet air temperature, $NO_x$ is increased due to a higher adiabatic flame temperature while CO is increased or decreased for low or high A/F ratio regime, respectively. depending on the flame location. With decreasing load from the design condition, $NO_x$ is decreased as thermal load is reduced. With further decreasing load, however, $NO_x$ is increased due to a longer residence time. CO is decreased and then increased with decreasing load. Flame extinction limit is extended with increasing inlet air temperature as the recirculation strength is enhanced.

레일신축이음 설치된 장대레일 적용 연속교의 구조물-궤도 상호작용에 의한 온도하중이 교량 받침에 미치는 영향 (Effects of Bridge Bearings by Structure-Track Interaction for Continuous Bridge applied CWR with Rail Expansion Joint under Temperature Load)

  • 정지승;이종순
    • 한국안전학회지
    • /
    • 제25권5호
    • /
    • pp.54-61
    • /
    • 2010
  • The additional axial force of CWR(continuous welded rail) is occurred by structure-track interaction, in reverse, fixed supports of structure are applied the large load by that. Ratio of load which transferred on support through the bridge superstructure with one-side REJ by acceleration and braking load are stated in High-Speed Rail Design Criteria(2005). On the other hand the horizontal forces of support delivered to the load due to thermal loads has been no report about the criteria. Therefore, this study was performed the review of the reaction and displacement on support by structure-track interaction in a special bridge(composite brdiges, 45+55+55+45=200m) with REJ acting on the temperature load. As a result, because fixed support of a special bridge or a continuous bridge with REJ under the temperature load which is constant load has been acted the large lateral load by structure-track interaction, when determining the fixed bearing capacity of structure should be reflected in the results to secure the safety of structures was confirmed.

비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구 (A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer)

  • 선윤숙;김진성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

개발한 국산화 유압 액셜피스톤모터의 특성실험 (Characteristics Experiment of Domestic Developed Hydraulic Axial Piston Motor)

  • 염만오;이상윤
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.70-76
    • /
    • 2007
  • The purpose of this study is to analyze the characteristics of a domestic developed hydraulic axial piston motor. An experimental apparatus was constructed and the output torque, the input oil pressure, the input flow rate, the speed of motor and oil temperature were measured. They were measured under both no load and load conditions. The results are as follows; 1. Motion of motor became steady state conditions after 5 seconds. 2. Output torque of motor was proportional to input oil pressure under both load and unload. 3. Speed of motor decreased with increasing load. 4. Oil temperature was almost constant. The results of this study will offer the basic data in designing and operating hydraulic axial piston motors.

고온초전도변압기의 특성시험 (Test of an High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;이지광;김우석;한송엽;류경우;최경달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF