• Title/Summary/Keyword: No concentration

Search Result 10,706, Processing Time 0.035 seconds

Characteristics in Atmospheric Chemistry between NO, NO2 and O3 at an Urban Site during MAPS (Megacity Air Pollution Study)-Seoul, Korea (서울 도심대기의 NO, NO2와 O3 사이의 대기화학적 특성 연구)

  • Kim, Deug-Soo;Jeong, Jinsang;Ahn, Joonyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.4
    • /
    • pp.422-434
    • /
    • 2016
  • This study was conducted to understand roles of $NO_x(=NO+NO_2)$ on high $O_3$ episodes at an urban monitoring station in Seoul. Concentrations of NO, $NO_2$, $NO_y$ and $O_3$ were measured intensively at KIST monitoring station which located at urban center in Seoul metropolitan area during May 18~June 13, 2015. Sampling period was planed because high $O_3$ and PM occurred frequently during from late spring to early summer months in Seoul. The experimental site locates in NW from center of Seoul and is surrounded by residential area. Belt highway of the city runs from north to west side nearby experimental site. Vehicle exhaust emissions due to heavy traffic influenced $NO_x$ concentration at the site during northwesterly wind. Specific $NO_2$ concentration was measured by Blue Light photolytic converter, and it was compared to $NO_2$ concentration measured by molybedenum converter. $[NO_2]_{phtolysis}$ was usually lower than $[NO_2]_{molybedenum}$ during the experiment period; however their diurnal variations were very similar. The linear relationship between these $NO_2$ concentrations was found to be $[NO_2]_{phtolysis}$=0.64 $[NO_2]_{molybedenum}$ - 2.6, $r^2$=0.83 during May 16~8, 2015. The difference between $NO_2$ by molybdenum converter and by photolytic converter (${\Delta}NO_2=[NO_2]_{molybedenum}-[NO_2]_{phtolysis}$) accounted for residual $NO_y$ which can represent $NO_z$ (=$NO_y-NO_x$). $O_3$ concentration showed typical daily trend which has maximum at late afternoon and minimum during the night. $O_3$ increased at a rate of 7 ppb/hr since 8 am. and reached the maximum concentration (~80 ppb) at 3 pm.. The diurnal pattern of $O_3$ was inversely related with that of $NO_2$, suggesting that the formation of $O_3$ was the result of photochemical activity of $NO_2$.

Effects of Nitrite Exposure on Plasma Nitrite Levels and Hepatic Drug-metabolizing Enzymes in the Carp, Cyprinus carpio (아질산 노출이 이스라엘잉어 혈장내 아질산 농도 및 간장 약물대사효소에 미치는 영향)

  • 박관하;최상훈;김영길;김용호;최선남;김종배
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.2
    • /
    • pp.69-76
    • /
    • 2003
  • Effects of ambient nitrite, NO$_2$$\^$-/, at 1, 3, 10 and 30 mg/1, on the changes of plasma nitrite/nitrate and on hepatic drug - metabolizing enzyme activity were examined in the juvenile Israeli carp, Cyprinus carpio. When the fish were exposed to 1 and 3 mg/1 NO$_2$$\^$-/, there was an exposure duration-dependent increase in plasma NO$_2$$\^$-/ over the 96-hr period reaching 6∼7 fold excess the ambient concentration. In the fish exposed to 10 mg/1, a plateau concentration of less than 2-fold of the environment was attained in 12 hr. With 30 mg/1, however, the maximal plasma NO$_2$$\^$-/ was 41.25 mg/1 at 12 hr followed by a gradual decline. There was a concentration-dependent increase in methemoglobin (metHb) level in all NO$_2$$\^$-/ -exposed groups and a significant decrease in hematocrit value in 30 mg/l group after 96-hr exposure. Apart from the blunted increase in plasma NO$_2$$\^$-/ with higher NO$_2$$\^$-/ (10 and 30 mg/1) exposure, the ratio of plasma NO$_3$$\^$-/ to NO$_2$$\^$-/ was signifirantly higher in these groups compared to 1 and 3 mg/1. The imbalance in the plasma NO$_3$$\^$-//NO$_2$$\^$-/ at higher NO$_2$$\^$-/ exposure suggests a possible accelerated conversion of NO$_2$$\^$-/ to NO$_3$$\^$-/. Nitrite exposure did not affect the hepatic drug-metabolic activities in juvenile Israeli carp. All these data indicate that disposition of NO$_2$- differ depending upon exposed concentration and that metHb production may not be the exclusive toxic mechanism in carp.

The Methods Calculating the Reduction Efficiency of Nitrogen Oxide for the Facilities Including the Low NOx Burners (저녹스 버너 설치 시설의 질소산화물 저감 효율 산정 방법)

  • Lee, Ki Yong;Talukder, Niladri
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.295-296
    • /
    • 2015
  • We presented the methods calculating the reduction efficiency of nitrogen oxide for the low $NO_x$ burner as the pollution prevention facilities. The standard $NO_x$ concentration was used on the emission factor of LNG, $3.7g/m^3$. The $NO_x$ reduction efficiency based on the $NO_x$ concentration was presented and the relationships between the $NO_x$ concentration and the emission factor or the specific heat emission factor were derived. These results could be accurately reflected on calculating the amount of the nitrogen oxide emissions. In addition, according to the arrangement of the low $NO_x$ burners the methods of applying their $NO_x$ reduction efficiency were proposed. The $NO_x$ reduction efficiency for the facilities consisting of the low $NO_x$ burners and the non-low $NO_x$ burners could be estimated with information about the reduction efficiency of each low $NO_x$ burners, the fuel consumption rate, and the heating value of fuel.

  • PDF

Quantification of nitric oxide concentration in the hemocytes of Manila clam Ruditapes philippinarum by using 4,5-diaminofluorescein diacetate (DAF-2) detection method (바지락 (Ruditapes philippinarum) 혈구의 일산화질소 (nitric oxide) 정량)

  • Nam, Ki-Woong;Yang, Hyun-Sung;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.29 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • Nitric oxide (NO) is an important intra-intercellular signaling molecule that regulates many physiological processes and participates in the development some pathological conditions in animals. In this study, we compared different methods for determining NO concentration in the hemocytes of Manila clam Ruditapes philippinarum. For measuring the intracellular NO levels, we used the specific fluorescent probe 4,5-diaminofluorescein diacetate (DAF-2 DA), and the quantification methods that were compared were based on image analysis, spectrophotometry, and flow cytometry. NO concentration could be determined using all the 3 methods, and the concentration varied significantly depending upon the presence of NO regulators in the hemocytes; NO concentration increased in the presence of L-arginine, while it decreased in the presence of N-nitro-L-arginine methyl ester. In particular, it is found that estimation of NO using a flowcytometry is more economical, reliable and accurate compared to image analysis and spectrophotometry. Accordingly we believe that determining NO concentration by using flowcytometry will be useful in evaluating physiological and pathological conditions in marine bivalves.

Effects of Wisoo(B-21) and Baekwhe(GV-20) acupuncture on serum glucose concentration and lipid composition in high fat diet induced diabetic rat (위유(胃兪)(B-21), 백회(百會)(GV-20)혈(穴) 자침(刺鍼)이 고지방식이(高脂肪食餌)에 의한 당뇨병유발(糖尿病誘發) 흰쥐의 혈청(血淸)Glucose 농도(濃度) 및 지질구성(脂質構成)에 미치는 영향(影響))

  • Lee Sang-Hoon;Lee Joon-Moo
    • Korean Journal of Acupuncture
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2003
  • Effects of Wisoo and Baekwhe acupuncture on serum glucose and lipid composition were investigated in high fat diet induced diabetic rat. Plasma glucose, free fatty acids and $\Beta-lipoprotein$ concentration showed a high reduction in wisoo acupuncture group compared to those of control group, however the values of baekwhe acupuncture group showed no significantly different those of control group. Plasma triglyceride and LDL-cholesterol concentration showed a tendency to decrease in the wisoo acupuncture groups, however the values of baekwhe showed no significantly different those of control group. Total cholesterol concentration showed a high reduction in wisoo acupuncture groups and HDL-cholesterol concentration showed a high values in wisoo acupuncture group, however these values no significantly different in all treatment groups.

  • PDF

A Study on Measurement of NO Concentrations in Laminar Premxied $CH_4/O_2/N_2$ Flames by LIF (레이저 유도 형광법(LIF)을 이용한 층류 메탄 예혼합 화염내 NO 농도측정에 관한 연구)

  • Kim, Sun-Wook;Jin, Seong-Ho;Kim, Gyung-Soo;Park, Kyoung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.156-161
    • /
    • 2000
  • In this study, quantitative nitric oxide concentration distributions are investigated in the post-flame zone of laminar premixed $CH_4/O_2/N_2$, flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different equivalence ratios varying from $0.8{\sim}1.4$, and flow rate is fixed as 5slpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interferences from Rayleigh scattering and $O_2$ fluorescence. NO concentration is rised when equivalence ratios increase at different vertical distances form nozzle tip. In any case, the maximum NO concentration reaches the maximum in reaction zone.

  • PDF

A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area (부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구)

  • Choi, Sung-Yong;Moon, Deog-Hwan;Lee, Jong-Tae;Song, In-Hyuk;Lee, Cha-Eun;Lee, Sung-Min
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

Sensitivity of Ozone to NOx and VOCs in a Street Canyon (도로 협곡에서 NOx와 VOCs에 대한 오존의 민감도)

  • Lee, Kwang-Yeon;Kwak, Kyung-Hwan;Park, Seung-Bu;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.307-316
    • /
    • 2013
  • The sensitivity of ozone to $NO_x$ and volatile organic compounds (VOCs) emission rates under different ventilation rates and $NO_2-to-NO_x$ emission ratios in a street canyon is investigated using a chemistry box model. The carbon bond mechanism IV (CBM-IV) with 36 gaseous species and 93 chemical reactions is incorporated. $NO_x$ and VOCs emission rates considered range from 0.01 to $0.30ppb\;s^{-1}$ with intervals of $0.01ppb\;s^{-1}$. Three different ventilation rates and three different $NO_2-to-NO_x$ emission ratios are considered. The simulation results show that the ozone concentration decreases with increasing $NO_x$ emission rate but increases with increasing VOCs emission rate. When the emission ratio of VOCs to $NO_x$ is smaller than about 4, the ozone concentration is lower in the street canyon than in the background. On average, the magnitude of the sensitivity of ozone to $NO_x$ emission rate is significantly larger than that to VOCs emission rate. As the $NO_x$ emission rate increases, the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates decreases. Because the ozone concentration is lower in the street canyon than in the background, the increased ventilation rate enhances ozone inflow from the background. Therefore, the increase in ventilation rate results in the increase in ozone concentration and the decrease in the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates when the emission ratio of VOCs to $NO_x$ is smaller than about 4. On the other hand, the increase in $NO_2-to-NO_x$ emission ratio results in the increase in ozone concentration because the chemical ozone production due to the $NO_2$ photolysis is enhanced. In the present experimental setup, the contribution of the change in $NO_2-to-NO_x$ emission ratio to the change in the sensitivity of ozone to $NO_x$ emission rate is larger than that of the change in ventilation rate.

Analysis of Toxic-PCBs in Sediment by Isotope Dilution HRGC/HRMS (Isotope Dilution HRGC/HRMS 방법을 이용한 저니토중 Toxic-PCBs 분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Park, Sun-Ku;Kim, Kyung-Sup
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.550-557
    • /
    • 1999
  • This Analysis was conducted for 13 toxic-PCBs having TEF value among 209 PCBs isomers in sediment by isotope dilution HRGC/HRMS method. From the result, the recovery of surrogate standard was in the range of 71~99%. The concentration range for 13 toxic-PCBs in sediment was found to be 0.84~2.49 ng/g, among them the concentration levels of 2,2',3,3',4,4',5-HpCB(IUPAC No. 170) and 2,2',3,4,4',5,5'-HpCB(IUPAC No. 180) represented almost 50% of total concentrarion and that of 2,3,4,4,5-PeCB(IUPAC No. 114) showed over 10%. The TEQ concentration levelwas in the range of 0.38~2.63 pg-TEQ/g and 3,3',4,4',5-PeCB(IUPAC No. 126) concentration represented over 50% of total TEQ concentration.

  • PDF

Monitoring of Nitrogen Ion in Nitrifying Biofilm using an Ion Selective Microelectrode (이온선택성 미소전극을 이용한 질산화 생물막내의 질소 이온의 농도 모니터링)

  • Seon, Ji-Yun;Byun, Im-Gyu;Lee, Tae-Ho;Park, Tae-Joo
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • An ion selective microelectrode (ISME) was fabricated to measure concentrations of ammonium (${NH_4}^+$-N) and nitrate (${NO_3}^-$-N) according to the depth of nitrifying biofilm. The limits of detectability and validity of results were investigated to evaluate the ISME. The electromotive force (EMF) was directly proportional to the ion concentration, and average detection limits of ${NH_4}^+$ and ${NO_3}^-$ ISME were $10^{-5.14}$ and $10^{-5.18}$ M, respectively. The concentrations of ${NH_4}^+ $-N and ${NO_3}^-$-N in various depths on the nitrifying biofilm were measured by the ISME. When a modified Ludzack-Ettinger (MLE) process was operated at an HRT of 6 h, concentration gradients of ${NH_4}^+$-N in the bulk solution and biofilm at depths of $100\;{\mu}m$ decreased by $70\;{\mu}M$, while ${NO_3}^-$-N increased by $101\;{\mu}M$ and remained constant thereafter. At an HRT of 4 h, concentration gradients of ${NH_4}^+$-N at depths of $500\;{\mu}m$ decreased by $160\;{\mu}M$ and ${NO_3}^-$-N increased by $162;{\mu}M$ and remained constant thereafter. As HRT decreased, the concentration gradients of ${NH_4}^+$-N and ${NO_3}^-$-N between bulk solution and biofilm was higher due to the increase of nitrogen load. Also, the concentration gradients of the ${NH_4}^+$-N and ${NO_3}^-$-N of biofilm in the second aerobic tank were lower than those of the first aerobic tank, suggesting differences of nitrogen load and concentrations of DO between the first and second aerobic tank.