• Title/Summary/Keyword: No Load Test

Search Result 689, Processing Time 0.032 seconds

Comparison of steady and unsteady simulation methodologies for predicting no-load speed in Francis turbines

  • Hosseinimanesh, Hossein;Devals, Christophe;Nennemann, Bernd;Guibault, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.155-168
    • /
    • 2015
  • No-load speed is an important performance factor for the safe operation of hydropower systems. In turbine design, the manufacturers must conduct several model tests to calculate the accurate value of no-load speed for the complete range of operating conditions, which are expensive and time-consuming. The present study presents steady and unsteady methods for calculating no-load speed of a Francis turbine. The steady simulations are implemented using a commercial flow solver and an iterative algorithm that relies on a smooth relation between turbine torque and speed factor. The unsteady method uses unsteady RANS simulations that have been integrated with a user subroutine to compute and return the value of runner speed, time step and friction torque. The main goal of this research is to evaluate and compare the two methods by calculating turbine dynamic parameters for three test cases consisting of high and medium head Francis turbines. Overall, the numerical results agreed well with experimental data. The unsteady method provided more accurate results in the opening angle range from 20 to 26 degrees. Nevertheless, the steady results showed more consistency than unsteady results for the three different test cases at different operating conditions.

Study on Real-Time Load Simulator for Testing Propulsion Inverter Test (추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구)

  • 김길동;신정렬;이우동;한석윤;박기준
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.

Test of an High Temperature Superconducting Power Transformer (고온초전도변압기의 특성시험)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Kim, U-Seok;Han, Song-Yeop;Ryu, Gyeong-U;Choe, Gyeong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.9
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF

Development of accelerated life test method for mechanical components using Weibull-IPL(Inverse Power Law) model (와이블-역승법을 이용한 기계류부품의 가속시험 방법 개발)

  • Lee, Geun-Ho;Kim, Hyoung-Eui;Kang, Bo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.445-450
    • /
    • 2003
  • This study was performed 10 develop the accelerated life test method using Weibull-IPL(Inverse Power Law) model for mechanical components. Weibull-IPL model is concerned with determining the assurance life with confidence level and the accelerated life test time From the relation of weibull distribution factors and confidence limit, the testing times on the no number of failure acceptance criteria arc determined. The mechanical components generally represent wear and fatigue characteristics as a failure mode. IPL based on the cumulative damage theory is applied effectively the mechanical components to reduce the testing time and to achieve the accelerating test conditions. As the actual application example, accelerated life test method of agricultural tractor transmission was described. Life distribution of agricultural tractor transmission was supposed to follow Weibull distribution and life test time was calculated under the conditions of average life (MTBF) 3,000 hours and 90% confidence level for one test sample. According to IPL, because test time call be shorten in case increase test load test time could be reduced by 482 hours when we put the load 1.1 times of rated load than 0.73 times of rated load that is equivalent load calculated by load spectrum of the agricultural tractor. This time, acceleration coefficient was 11.7.

  • PDF

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

Strengthening Effects of Epoxy Mortar Systems on Reinforced Concrete Beams by Flexural Tensile Strength (변성에폭시 모르터 휨인장강도가 단면증대 보에 미치는 영향)

  • 류현희;신영수;정혜교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.787-790
    • /
    • 2000
  • This paper presents an experimental study on flexural behavior of structural member enlarged with epoxy mortar system. The main test variable is flexural tensile strength. A series of 4 test beams was tested to shoe the corresponding effect of each variables on maximum load capacity, load-deflection and moment-curvature relationship, interface behavior and failure mode. The results show that the flexural tensile strength of retrofitted materials have no relation load-deflection, but to load-strain, and failure mode.

  • PDF

Effects of Loading Conditions on Consolidation Beharion of the Soft Clay (하중조건이 연약초토의 압밀에 미치는 영향)

  • 강병희
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.4
    • /
    • pp.2445-2455
    • /
    • 1971
  • One-dimensional Consolidation tests with pore pressure measurement were caried in the ANTE-US consolidometer in order to investigate the effects of loading conditions on consolidation behavior of the soft clay. Undisturbed specimens of a sensitive clay were loaded in load-increment ratioes 0.5, 1.0 and 2.0, and load increment duration of 1, 6, 12, 24 and 48 hours with the application of 40 psi of back pressure. There is no significant effect of load-increment ratio on compression-pressure relationship, but the test with one-hour load increment duration doesn't represent the same results of the standard consolidation test in the sensitive clay.

  • PDF

Characteristics of a 10kVA three phase superconducting power transformer (3상 10kVA 고온초전도 변압기의 특성)

  • Lee, S.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.24-26
    • /
    • 2001
  • The high temperature super-conductor transformer gains interests from the industries. This paper described construction and test results of a 10kVA HTS transformer. Three phase transformer with double pancake windings were constructed. BSCCO-2223 wire, silicon sheet steel core and FRP cryostats were used in that transformer After the test of basic properties of the 3 phase HTS transformer using no load test, short ciucuit test and full load test, continuous operation of 100 hours with pure resistive load has been carried out. Test proved over-load capability and reliability of the HTS transformer.

  • PDF

Research on the Relation of the Exhaust Gas Concentration between Lug-Dowrn3 Test Mode and D147 Test Mode on the Driving Car Using Diesel Fuel (운행경유화 배출가스 Lug-Down3 모드 부하검사방법과 D147모드 부하검사방법간의 배출농도 상관성 비교 연구)

  • Jo, Jeong-Gwon;Lee, Dong-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2008.10a
    • /
    • pp.62-65
    • /
    • 2008
  • In this paper, we estimated the D147 mode test, which is introduced as a new emission test mode for the driving car using diesel fuel. And we compared the D147 test mode, Lug-Down3 test mode and no load acceleration test mode. And the exhaust gas concentration between the three modes was compared. The exhaust concentration at the D147 mode is lower than the exhause concentration at the Lug-Down 3 mode and higher than that at the no load acceleration test mode. Also the correlation factor was estimated between the D147 mode and Lug-Down 3 mode.

  • PDF

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF