• Title/Summary/Keyword: Nitrogen Flushing

Search Result 35, Processing Time 0.027 seconds

Effects of nitrogen gas flushing in comparison with argon on rumen fermentation characteristics in in vitro studies

  • Park, KiYeon;Lee, HongGu
    • Journal of Animal Science and Technology
    • /
    • v.62 no.1
    • /
    • pp.52-57
    • /
    • 2020
  • In rumen in vitro experiments, although nitrogen gas (N2) flushing has been widely used, its effects on rumen fermentation characteristics are not clearly determined. The present study is the first to evaluate the effects of N2 flushing on rumen fermentation characteristics in in vitro batch culture system by comparing with new applicable non-metabolizable gas: argon (Ar). The rumen fluid was taken from two Korean native heifers followed by incubation for 3, 9, 12, and 24 h with N2 or Ar flushing. As a result, in all incubation time, N2 flushing resulted in higher total gas production than Ar flushing (p < 0.01). Additionally, in N2 flushing group, ammonia nitrogen was increased (p < 0.01). However, volatile fatty acids profiles and pH were not affected by the flushing gases (p > 0.05). In conclusion, the present study demonstrated that N2 flushing can influence the rumen nitrogen metabolism via increased ammonia nitrogen concentration and Ar flushing can be used as a new alternative flushing gas.

Impact of a Flushing Discharge from an Upstream Dam on the NH3-N Concentrations during Winter Season in Geum River (상류 댐 플러싱 방류가 금강의 겨울철 암모니아성 질소 농도 저감에 미치는 효과분석)

  • Chung, Se Woong;Kim, Yu-kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.609-616
    • /
    • 2005
  • A high ammonia nitrogen ($NH_3-N$) concentration has been recursively observed every winter season in Geum River, which hindered chemical treatment processes at a water treatment plant. A flushing discharge from Daecheong Dam was often considered to dilute $NH_3-N$, but information on the quantitative effect of flushing on the downstream water quality was limited. In this study, the impact of a short-term reservoir flushing on the downstream water quality was investigated through field experiments and unsteady water quality modeling. On November 22, 2003, the reservoir discharge was increased from $30m^3/sec$ to $200m^3/sec$ within 6 hours for the purpose of the experiment. The results showed that flushing flow tends to reduce downstream $NH_3-N$ concentrations considerably, but the effectiveness was limited by flushing amount and time. An unsteady river water quality model was applied to simulate the changes of nitrogen concentrations in response to reservoir flushing. The model showed very good performance in predicting the travel time of flushing flow and the effect of flushing discharge on the reduction of downstream $NH_3-N$ concentrations at Maepo and Geumnam site, but a significant discrepancy was observed at Gongju site.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Photocatalyst and Alumina Microfiltration: Effect of Organic Matters at Nitrogen Back-flushing (광촉매 및 알루미나 정밀여과 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척시 유기물의 영향)

  • Park, Jin Yong;Sim, Sung Bo
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.441-449
    • /
    • 2012
  • Effect of humic acid (HA) with periodic nitrogen back-flushing was investigated in hybrid process of alumina microfiltration and photocatalyst for drinking water treatment. It was compared and investigated with the previous results of microfiltration water back-flushing or ultrafiltration nitrogen back-flushing in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As results, the trends of membrane fouling were different depending on nitrogen or water back-flushing, and depending on ultrafiltration or microfiltration made with the same material. Also, the nitrogen back-flushing using microfiltration was more effective membrane fouling inhibition than ultrafiltration, and the nitrogen back-flushing was more effective than water back-flushing using the same microfiltration membrane. Turbidity treatment efficiencies were almost constant independent of HA concentration, but HA treatment efficiency was the maximum at HA 10 mg/L. From this results, it was shown that the treated water HA quality increased as increasing HA concentration, but HA could be removed the most effectively by photocatalyst beads adsorption and photo-oxidation at HA 10 mg/L.

Effect of pH and Oxygen Back-flushing on Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads (관형 세라믹 정밀여과와 광촉매 첨가 PES 구를 이용한 혼성 수처리 공정에서 pH 및 산소 역세척의 영향)

  • Park, Jin Yong;Park, Sung Woo;Byun, Hongsik
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.39-49
    • /
    • 2014
  • The effects of pH and oxygen back-flushing were investigated in hybrid process of ceramic microfiltration and PES (polyethersulfone) beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As increasing pH, $R_f$ decreased and J increased. Finally the maximum $V_T$ could be acquired at pH 9. Treatment efficiencies of turbidity was almost same independent of pH. Treatment efficiency of dissolved organic matters (DOM) decreased as increasing pH. As results of comparing the oxygen and nitrogen back-flushing, $R_{f,180}$ at oxygen back-flushing was the lower than that at nitrogen back-flushing, and the dimensionless final permeate flux ($J_{180}/J_0$) by initial permeate flux ($J_0$) at oxygen back-flushing was maintained the higher than that at nitrogen back-flushing except 10 and 12 min of back-flushing period (FT). Treatment efficiency of turbidity at oxygen back-flushing was a little higher than that at nitrogen back-flushing. Treatment efficiency of the DOM at nitrogen back-flushing was the higher than that at oxygen back-flushing. Also, treatment efficiency of turbidity at saturated oxygen was similar with those of oxygen and nitrogen back-flushing, but the treatment efficiency of DOM was increased significantly because OH radical could be generated by reaction between saturated oxygen and photocatalyst.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Water Back-flushing Period and Time (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 물 역세척 주기와 시간의 영향)

  • Park, Jin Yong;Park, Sung Woo;Byun, Hongsik
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.267-277
    • /
    • 2013
  • The effect of water back-flushing period (FT) and water back-flushing time (BT) was compared with the previous study of nitrogen back-flushing in viewpoints of resistance of membrane fouling ($R_f$), permeate flux (J), and total permeate volume ($V_T$) in hybrid process of tubular ceramic microfiltration and PES (polyethersulfone) beads loaded $TiO_2$ photocatalyst for advanced drinking water treatment. As FT decreasing, Rf decreased, but J and $V_T$ increased. Turdity treatment efficiency was the maximum at NBF (no back-flushing) and increased a little as FT decreasing in both water and nitrogen back-flushing. Organic matter treatment efficiency was the maximum at FT 4 min in water back-flushing, but increased as FT decreasing in nitrogen back-flushing. As BT increasing, Rf and resistance of reversible membrane fouling ($R_{rf}$) decreased, but J and $V_T$ increased. The turdity treatment efficiency was almost constant beyond 98% in water back-flushing, but increased as BT increasing except NBF in nitrogen. The organic matter treatment efficiency was the maximum at BT 6 sec in water back-flushing, but increased as BT increasing except NBF in nitrogen. The $V_T$ was the maximum at BT 30 and FT 2 min, and optimal condition was BT 30 sec per FT 2 min in this experimental range.

A Study on Process Design of Hot Oil Flushing System Using Oil-Nitrogen Gas Mixing Fluid (오일-질소가스 혼합유체를 이용한 고온 오일플러싱 시스템 공정설계에 관한 연구)

  • Lee, Yoon-Ho;Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.541-548
    • /
    • 2017
  • A theoretical study on gas-liquid two-phase flow flushing systemnitrogen gas to the oil used for existing flushing equipment was conducted on the basis of ISO code so as to improve performance of existing high-temperature oil flushing equipment used in ocean plant facility drying field. For study, we analyzed process simulation results mixed fluid mixing ratio, temperature, Reynolds number and liquid hold up affectcleaning performance after designing oil-nitrogen gas mixture flushing system process. As a result, as the volume flow rate of mixed fluid increases with the tube diameter the volume fraction of the gas phase constant, the liquid fraction difference value at the inlet and outlet of horizontal hydraulic piping increases. It was found that the phase distribution between oil and nitrogen gas bubbles varies depending on the position the pipe lengthdirection. This change in phase distribution is expected to have a significant impact on the clean performance of an oil-nitrogen gas mixture flushing system.

Effects of Nitrogen Flushing on the Storage Stability of Red Pepper Powders (고추가루의 저장성에 미치는 질소치환의 영향)

  • Kim, Hyun-Ku;Jo, Kil-Suk;Park, Mu-Hyun;Chang, Young-Sang;Shin, Zae-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.7
    • /
    • pp.833-839
    • /
    • 1990
  • To examine the effects of nitrogen flushing on the storage stability of red pepper powders, the color and capsanthin and capsaicin contents were investigated. Capsanthin and capsaicin contents of red pepper powders during their storage decreased as the increase of temperature. Nitrogen flushing packaging was good for the retention of capsanthin and capsaicin than air packaging. Brown color of red pepper powders during their storage differed with storage temperature and packaging condition, thus low temperature and nitrogen reduced the brown color substantially, L and b values by Hunter's color were almost not changed during 10 months storage of red pepper powders, and a value was decreased as the increase of temperature. Therefore, nitrogen flushing packaging for the storage of red pepper powders was good than air packaging.

  • PDF

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads: Effect of Organic Matters, Adsorption and Photo-oxidation at Water Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리: 물 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Park, Sung Woo;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.159-169
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. The results of water and nitrogen back-flushing were compared in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as increasing HA, Rf increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. Average turbidity treatment efficiencies were almost same independent of HA concentration. Average organic matter treatment efficiency was the minimum 71.4% at 10 mg/L HA in water back-flushing, but those were almost constant in nitrogen back-flushing. The hybrid process of MF, PES beads, and UV (MF + $TiO_2$ + UV) have the lowest $R_f$, and the highest J and $V_T$ in both water and nitrogen back-flushing. The turbidity and organic matter treatment efficiencies were the maximum at MF + $TiO_2$ + UV independent of water and nitrogen back-flushing, and decreased sequently as simplifying the process to MF. However, adsorption performed the more important role than photo-oxidation in water back-flushing, and photo- oxidation was the more than adsorption in nitrogen back-flushing.

지하수의 라듐/라돈 동시측정을 위한 백그라운드 감마선 제어

  • Lee Gil-Yong;Yun Yun-Yeol;Jo Su-Yeong;Kim Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.308-311
    • /
    • 2005
  • [ $^{222}Rn\;and\;^{226}Ra$ ] in groundwater were determined simultaneously using a gamma-spectroscopy. A nitrogen flushing equipment has been used for elimination and stabilization of high and unstable background activity due to the radon and its progenies in counting shield and room. The aim of present work was to control the background activity for simultaneous measurement of radium$(^{226}Ra)$ and radon$(^{222}Rn)$ in groundwater using a gamma-spectrometry. Background activity was about 1.0dps and the standard deviation was about 50%, The background activity could be minimized using nitrogen flushing equipment in the range of 0.1 to 0.5 and the RSD was about 5% at the experimental condition. The detection limit of $^{222}Rn\;and\;^{226}Ra$ in groundwater was 0.5dps/L in the background control method. In most groundwater used in the work, radon activity was more than the detection limit. However, radium activity in some groundwater was less than the detection limit. If the low level radium in groundwater must be measured, preconcentration process such as concentration should be performed before measuring the groundwater.

  • PDF

Effect of pH, Saturated Oxygen, and Back-flushing Media in Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst-loaded PES Beads (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성수처리에서 pH 및 포화산소, 역세척 매체의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2014
  • The effects of pH, saturated oxygen, and back-flushing media were investigated in hybrid process of tubular ceramic microfiltration and $TiO_2$ photocatalyst-loaded PES (polyethersulfone) beads for advanced drinking water treatment, and compared results of water, nitrogen, or oxygen back-flushing in the viewpoints of membrane fouling resistance ($R_f$), permeate flux (J) and total treated water ($V_T$). $R_f$ decreased, and J and $V_T$ increased as decreasing pH. Turbidity treatment efficiencies were similar at water or nitrogen back-flushing independent of pH, but DOM (dissolved organic matter) treatment efficiency did not have a trend at water back-flushing. $R_f$ at NBF (no back-flushing) with SO (saturated oxygen) was the lower than that at NBF without SO. Also, the DOM treatment efficiency at NBF with SO was the lower than that at NBF without SO. It happened because OH radicals produced by reaction of SO and photocatalyst could dilute with water inside the module. The DOM treatment efficiency of gas back-flushing showed the larger than that of water back-flushing at back-flushig period 10 min. It proved that the adsorption or photo-oxidation of PES beads could be activated by the more effective bead-cleaning of gas back-flushing than water back-flushing.