DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

겨울 야간 하늘에 노출된 평판에 의한 복사냉각 실험 (Nocturnal Radiant Cooling during the Winter by the Plate Viewing the Sky)

  • 변기홍
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.49-55
    • /
    • 2008
  • The radiant cooling(RC) effects are studied during the winter night. The plate was viewing the nighttime sky. The data were collected at the rooftop of the Engineering building at the Dongguk University in Seoul, Korea. As observed during the summer night, the plate temperature was lower than ambient temperature under the RC favorable conditions. The parameters under study are the wind velocity, cloud index, and visibility for given system size and surface condition. The results follow the same tendency with these parameters as observed from the previous study for the summer night. As long as the wind velocity is less than around 2 m/s, the radiant cooling was observed with the system under study. In some cases, the radiant cooling temperature differences (RCTD) are higher than those for the summer night. The larger the RCTD as the wind velocity decreases and as the sky becomes clear.

중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구 (Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System)

  • 황진원;안병천
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6759-6765
    • /
    • 2015
  • 본 연구에서는 자연외기를 활용하여 건물의 중앙냉방시스템에 대한 에너지를 절약하기 위한 제어방법으로서 외기온도 조건을 고려한 나이트 퍼지제어의 적용방안에 대해 시뮬레이션 연구가 수행되었다. 외기온도의 변화특성 및 건물의 축냉성능 등이 고려되었으며, 나이트 퍼지제어를 위한 운전시작시간과 제어설정온도의 선정방안이 연구되었다. 본 연구를 위하여 TRNSYS 프로그램을 활용하여 시스템 해석 모델링을 수행하였으며, 기존 제어방식 대비 제안된 제어방법의 에너지 절약성능을 비교 분석하였다. 연구결과로 외기온도 변화에 따라 나이트 퍼지제어를 위한 운전조건을 선정한 제안된 제어방법이 기존의 나이트 퍼지제어 제어방식과 비교하였을 때는 최대 16.8%, 나이트 퍼지제어를 적용하지 않은 경우에 비해서는 최대 28.6%의 에너지 절감이 가능함을 알 수 있었다.

가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구 (A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System)

  • 윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.

온실 냉방을 위한 히트펌프의 성능 분석 (Performance Analysis of Heat Pump System for Greenhouse Cooling)

  • 윤용철;서원명;이석건
    • 한국농공학회지
    • /
    • 제43권6호
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF

폐광의 냉기 및 냉수를 이용한 온실의 야냉 시스템 개발 (Development of Night Cooling System for Greenhouse Using Cool Air and Water from an Abandoned Coal Mine)

  • 강화석;강위수;이귀현;오재헌;김일섭;류근창
    • 한국환경농학회지
    • /
    • 제15권2호
    • /
    • pp.223-231
    • /
    • 1996
  • 폐광으로부터 유출되는 냉기 또는 냉수를 이용하여 여름 동안 야간에 온실을 냉방시키는데 있어 가장 효율적인 냉각방법을 결정하기 위해 여러 종류의 냉각 장치가 제작 및 냉각 실험되어졌다. 온실을 냉방시키는데 있어 여러 냉각장치의 효율을 비교할 때 독립적으로 소형 radiator, 냉각 pad 및 냉기를 사용한 냉각방법은 거의 비슷한 결과를 나타냈다. 또한 대형 radiator를 제외한 여러 냉각장치를 동시에 가동하였을 때는 독립적으로 이러한 냉각장치를 각각 가동하였을 때 보다 약간 향상된 냉각 효율을 나타냈다. 그러나 대형 radiator를 독립적으로 사용했을 때 온실의 냉각 효율은 다른 냉각 방법에 비하여 상당히 좋았으며, 야간의 외기 온도가 $23-24^{\circ}C$ 범위에 있을 때 온실내의 공기 온도는 약 $15^{\circ}C$로 냉각되었다.

  • PDF

전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석 (Energy Saving Effect of the Night Purge Control using ERV in a School Building)

  • 김수연;원정관;김재형;송두삼
    • 설비공학논문집
    • /
    • 제28권11호
    • /
    • pp.421-427
    • /
    • 2016
  • The indoor temperature of a building increases during the day due to solar radiation. This behavior is significant in school buildings that are finished with high thermal capacity materials. Moreover, in school buildings, windows cannot be opened until the class has finished owing to the security policy of schools. Consequently, classrooms maintain a high temperature throughout the morning. It is thus important to remove the indoor heat before the commencement of classes in order to reduce the cooling energy needed. The Energy Recovery Ventilator (ERV) system is currently being installed in school buildings for ventilating the classrooms. Night-purge control using ERV can be a good strategy to cool the classroom in advance of the operation of the cooling system. However, the optimal operation method of the ERV for night-purge control has not yet been reported. In this study, the effect of night-purge control with ERV in school buildings is analyzed by simulation method. The results of this study showed that the energy saving effect of night-purge control with ERV is most effective in the case of 2 hours operation prior to the commencement of the first lass and when enthalpy based outdoor air cooling is used.

RTS-SAREK을 이용한 사무용 건물의 나이트 퍼지 성능 평가 (Night Purge Evaluation Using the RTS-SAREK in Office Buildings)

  • 신동신;박성근;박영수;박지수;이진영
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.633-638
    • /
    • 2015
  • This study evaluates the capacity of night purging in office buildings to reduce the cooling load. RTS-SAREK is used to estimate the performance of night purging on the steady state. To overcome steady state RTS program limitations, we added unsteady heat transfer equations. When the ACH (Air Change per Hour) increases, the wall temperature decreases in both the steady and unsteady states. The unsteady heat transfer rate is different from the steady transfer rate, which validates the unsteady calculation. When ACH is low, the heat transfer rate increases continuously with time. When ACH becomes higher, the heat transfer rate increases and decreases with time. When ACH is quite high, there exists a large difference in the heat transfer rate between the steady and unsteady calculations, which emphasizes the importance of the unsteady calculation.

진공냉각장치와 그 이용 (Vacuum Cooling System and Their Use)

  • 김명환;김경근;박형진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.7-16
    • /
    • 1995
  • This article describes the working prnciple, structure and main characteristics of vacuum coolers for vegetables, and gives concrete examples of vacuum coolers that srebeing put to practical use. In particular, newly-developed cavuum coolers with cold storage, utilizing night-time electricity, are focused upon. Processing plants for vegetables, cold-storage rooms and vacuum cooling devices were investigated as possible application of vacuum cooling technology.

  • PDF

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.