• Title/Summary/Keyword: Nickel(I)

Search Result 213, Processing Time 0.021 seconds

Interdiffusion Studies of βNiAl Bond Coats: Understanding the Zr, Pt, and Al Migration Trends and Their Beneficial Effects

  • Chandio, Ali Dad;Haque, Nafisul;Shaikh, Asif Ahmed
    • Korean Journal of Materials Research
    • /
    • v.31 no.8
    • /
    • pp.439-444
    • /
    • 2021
  • The oxidation resistance of the diffusion aluminide bond coat (BC) is compromised largely by interdiffusion (ID) effects on coated turbine blades of aeroengines. The present study is designed to understand the influence of ID on βNiAl coatings or BC. In this regard, nickel substrate and CMSX-4 superalloy are deposited. In total, four sets of BCs are developed, i.e. pure βNiAl (on Ni substrate), simple βNiAl (on CMSX-4 substrate), Zr-βNiAl (on CMSX-4 substrate) and Pt-βNiAl (on CMSX-4 substrate). The main aim of this study is to understand the interdiffusion of Al, Zr and Pt during preparation and oxidation. In addition, the beneficial effects of both Zr and platinum are assessed. Pure βNiAl and simple βNiAl show Ni-out-diffusion, whereas for platinum inward diffusion to the substrate is noticed under vacuum treatment. Interestingly, Zr-βNiAl shows the least ID in all BCs and exhibit stability under both vacuum and oxidation treatments. However, its spallation resistance is slightly lower than that of Pt-βNiAl BC. All BCs show similar oxide growth trends, except for Zr-βNiAl, which exhibits two-stage oxidations, i.e. transient and steady-state. Moreover, it is suggested that the localized spallation in all BCs is caused by βNiAl - γ'-Ni3Al transformation.

A STUDY ON METAL RELEASE OF TIN ION-PLATED STAINLESS STEEL ORTHODONTIC APPLIANCES (TiN 피막 처리된 스테인레스강 교정용 장치물의 금속 유리에 대한 연구)

  • KIM, Myung-Sook;Sung, Jae-Hyun;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.43-54
    • /
    • 1995
  • This study was conducted to examine the metal release of TiN-plated stainless steel orthodontic appliances by constructing the simulated orthodontic appliances equivalent to maxillary half arch, by dividing into TiN-plated and TiN-nonplated Bloops and by dividing again these groups into welded and nonwelded groups. And then, the total quantity of metal release was obtained by measuring the amounts of both soluble and precipitated nickel and chromium after immersing in artificial saliva for 15 days. And then, the corrosion appearance of surface structure was observed by using SEM. The results of this study were summarized as follows. 1. The total amounts of released nickel and chromium showed that the TiN-plated group after welding(Group 1) was 25.46 ${\mu}g$, respectively, and 17.4 ${\mu}g$, while the TiN-nonplated group after welding(Group III) was 54.69 ${\mu}g$, respectively, and 85.27 ${\mu}g$. Then, the TiN-Plated group indicated less amounts of metal release(p<0.05). 2. The total amounts of the TiN-plated group without welding(Group II) was 0.05${\mu}g$ and 0.34${\mu}g$, respectively. Then, it was shown that the TiN-plated group without welding(Group II) indicated less metal release than that of the TiN-Plated group after welding(Group I)(p<0.01, p<0.05). 3. When observing their surface structure, there were a lot of precipitate and pitting corrosion in the groups with welding(Group I & III), when the TiN-plated group(Group I) showed lower level than the TiN-nonplated group(Group IIII). On the other hand, the groups without welding(Group II & IV) indicated a little of pitting corrosion. 4. In case of observation with the naked eyes, it was shown that there were significant disco1oration and corrosion in the groups with welding(Group I & III), while there was no any remarkable change in the groups without welding(Group II & IV).

  • PDF

A Study on the Magnetic Properties of the Co-Ni-P thin Plate by Electroless Plating (무전해도금법에 의한 Co-Ni-P 박막의 자기적특성에 관한 연구)

  • Kim, C.W.;Lee, C.;Yoon, S.R.;Joung, I.
    • Korean Journal of Materials Research
    • /
    • v.5 no.8
    • /
    • pp.1013-1019
    • /
    • 1995
  • The thin plate of Co-Ni-P was deposited on the polyester film by the electroless plating method. Through present experiments, deposition rates and metal compositions of the plates were determined according to compositions of solution, pH and temperature. Also, magnetic properties of plates were examined according to metal compositions. Considering magnetic properties and deposition rates of electroless plating, the best condition was obtained as pH of 8.5 and 90℃. It was observed that metal compositions were evidently varied by the pH of solutions and the concentration of complex agents. However. they were not affected by other factors. At the optimum condition, the composition of the plate was Co(78%), Ni(16%), and P(6%). Also, it was found that the coercive force was 370 Oe, and squareness was 0.65 at this condition. Magnetic properties (hard or soft) of thin plates were determined by metal compositions. Therefore. the plate became soft magnetic plate as the composition of nickel increased over 30 per cents. The crystal structure of the soft magnetic plate was found to be amorphous in which it was strongly oriented to the (111)phahe of nickel. On the ohter hand, the hard magnetic place was found to be hcp crystalline of α-cobalt which was oriented to the (101)phase of cobalt and the (100)phase of cobalt.

  • PDF

A Study of the Slip Structure of an Aged and Deformed Nickel-Base Superalloy

  • Park, Hyung-Sup;Park, Ju
    • Nuclear Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.163-178
    • /
    • 1970
  • Deformation modes at room temperature and the interaction between slip lines and ${\gamma}$' precipitate particles in heat treated Rene 41 were studied by means of replica techniques in an electron microscope. The alloy had been deformed by compression after aging for times up to 9300 hr at 76$0^{\circ}C$ and 87$0^{\circ}C$. The slip structure observed was similar to that of o brass, i.e., consisting of single slip lines occurred on the{111}<110> system. The slip structure was also correlated with aging conditions. Slip lines appeared to pass through ${\gamma}$' particles, shearing them with the matrix even after a prolonged heat treatment. It was concluded on the basis of comparison with previously published data that ${\gamma}$' particles remain at least partially coherent with the matrix even in a greatly overaged condition.

  • PDF

Study on Heavy Metal Contents in Air of Den Tal Laboratories and Urine of Dental Laboratory Technicians in CHONBUK Area (전북지방 치과기공실 공기중 및 치과기공사의 뇨중중금속 함량에 관한 연구)

  • 이정오;이종섭;유인수
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 1990
  • For this study, I used the urine of 100 dental laboratroy technicians and 24 students in Chonbuk region. The purposes of this study were to investigate concentrations of cadmium (Cd), nickel (Ni) and chromium (Cr) in the air of dental laboratories. The results were as follows: 1. The concentrations of Cd is 0.0115mg/m$^{3}$ in the porcelain part, 0.0090mg/m$^{3}$ in the polishing part, that of Ni is 0.2864mg/m$^{3}$ in the porcelain part, 0.3188mg/m$^{3}$ in the polishing part, that of Cr is 0.0448mg/m$^{3}$ in the porcelain part, 0.1032mg/m$^{3}$ in the polishing part. 2. The concentrations of Cd, Ni and Cr in the technicians urine are 3.06 $\mu$g/l, 44.55 $\mu$g/l and 14.58 $\mu$g/l. Those of students, urine as the control group are 1.93 $\mu$g/l, 19.05 $\mu$g/l and 7.48 $\mu$g/l. There is significant difference between experimental group and control group (P < 0.01). 3. Watching for age and working place, 31-40 years age group reveals the highest group in the concentrations of Cd. Over 41 year age group represents the highest group in the concentrations of Ni and Cr (P < 0.01) The concentration of Cd turns up the highest in the partial part and that of Ni and Cr appears the highest in the polishing part (P < 0.01). Looking into working age, over 7 year group is the highest group in the concentrations of all investigated (P < 0.05).

  • PDF

Effects of Bath Compositions and Plating Conditions on Electroless Copper Plating Rate with Sodium Hypophosphite as Reducing Agent (환원제로 차아인산나트륨을 사용한 무전해 동도금속도에 미치는 도금액 조성과 도금조건의 영향)

  • Oh, I.S;Park, J.D.;Bai, Y.H.
    • Journal of Power System Engineering
    • /
    • v.5 no.2
    • /
    • pp.71-78
    • /
    • 2001
  • Using sodium hypophosphite as reducing agent, bath composition and plating condition of electroless copper plating on plating rate have been studied. The followings were determined as optimum, bath composition; $CuSO_4\;0.025M,\;NiSO_4\;0.002M,\;NaH_2PO_2\;0.4M$, sodium citrate 0.06M, $H_3BO_3$ 0.6M, thiourea or 2-MBT $0.2mg/{\ell}$, and operation conditions; pH $9{\sim}10$ at bath temperature rage of $60{\sim}70^{\circ}C$. A small amount of nickel ion($Ni^{2+}/Cu^{2+}$=0.002/0.025) to the hypophosphite reduced solution promotes autocatalysis and continuous plating. An additive such as thiourea or 2-MBT of a small amount($0.2mg/{\ell}$) can be used to stabilize the solution without changing plating rate much. The attivation energy between $20^{\circ}C\;and\;70^{\circ}C$ were calculated to be 11.3kcal/mol for deposition weight. Plating reaction had been ceased by the adjustment of pH above 13, temperature higher than $90^{\circ}C\;and\;under\;20^{\circ}C$. Deposited surface became worse in the case of increment of bath temperature above $80^{\circ}C$.

  • PDF

Biomechanical considerations for uprighting impacted mandibular molars

  • Morita, Yukiko;Koga, Yoshiyuki;Nguyen, Tuan Anh;Yoshida, Noriaki
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.268-277
    • /
    • 2020
  • This case report demonstrates two different uprighting mechanics separately applied to mesially tipped mandibular first and second molars. The biomechanical considerations for application of these mechanisms are also discussed. For repositioning of the first molar, which was severely tipped and deeply impacted, a novel cantilever mechanics was used. The molar tube was bonded in the buccolingual direction to facilitate insertion of a cantilever from the buccal side. By twisting the distal end of the cantilever, sufficient uprighting moment was generated. The mesial end of the cantilever was hooked over the miniscrew placed between the canine and first premolar, which could prevent exertion of an intrusive force to the anterior portion of the dentition as a side effect. For repositioning of the second molar, an uprighting mechanics using a compression force with two step bends incorporated into a nickel-titanium archwire was employed. This generated an uprighting moment as well as a distal force acting on the tipped second molar to regain the lost space for the first molar and bring it into its normal position. This epoch-making uprighting mechanics could also minimize the extrusion of the molar, thereby preventing occlusal interference by increasing interocclusal clearance between the inferiorly placed two step bends and the antagonist tooth. Consequently, the two step bends could help prevent occlusal interference. After 2 years and 11 months of active treatment, a desirable Class I occlusion was successfully achieved without permanent tooth extraction.

Exploratory research on ultra-long polymer optical fiber-based corrosion sensing for buried metal pipelines

  • Luo, Dong;Li, Yuanyuan;Yang, Hangzhou;Sun, Hao;Chen, Hongbin
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.507-520
    • /
    • 2020
  • In order to achieve effective corrosion monitoring of buried metal pipelines, a Novel nondestructive Testing (NDT) methodology using ultra-long (250 mm) Polymer Optical Fiber (POF) sensors coated with the Fe-C alloy film is proposed in this study. The theoretical principle is investigated to clarify the monitoring mechanism of this method, and the detailed fabrication process of this novel POF sensor is presented. To validate the feasibility of this novel POF sensor, exploratory research of the proposed method was performed using simulated corrosion tests. For simplicity, the geometric shape of the buried pipeline was simulated as a round hot-rolled plain steel bar. A thin nickel layer was applied as the inner plated layer, and the Fe-C alloy film was coated using an electroless plating technique to precisely control the thickness of the alloy film. In the end, systematic sensitivity analysis on corrosion severity was further performed with experimental studies on three sensors fabricated with different metal layer thicknesses of 25 ㎛, 30 ㎛ and 35 ㎛. The experimental observation demonstrated that the sensor coated with 25 ㎛ Fe-C alloy film presented the highest effectiveness with the corrosion sensitivity of 0.3364 mV/g at Δm = 9.32 × 10-4 g in Stage I and 0.0121 mV/g in Stage III. The research findings indicate that the detection accuracy of the novel POF sensor proposed in this study is satisfying. Moreover, the simple fabrication of the high-sensitivity sensor makes it cost-effective and suitable for the on-site corrosion monitoring of buried metal pipelines.

Heterologous Expression of Human $\beta$-Defensin-1 in Bacteriocin-Producing Laetoeoeeus lactis

  • CHOI HAK JONG;SEO MYUNG JI;LEE JUNG CHOUL;CHEIGH CHAN ICK;PARK HOON;AHN CHEOL;PYUN YU RYANG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.330-336
    • /
    • 2005
  • Lactococcus lactis A164 is a nisin Z-producing strain isolated from kimchi. Its antimicrobial spectrum has been found to be active against most Gram-positive bacteria tested, yet inactive against Gram-negative bacteria [3]. Accordingly, to overcome this drawback, the current study attempted to express human $\beta$-defensin-l (hBD-l), which kills both Gram-positive and Gram-negative bacteria in L. lactis AI64. When the hBD-l cDNA was introduced using a nisin Z-controlled expression cassette, the L. lactis A164 transformants grew very poorly, due to the bactericidal effect of the expressed hBD-l against the transformants. Therefore, a gene fusion system was designed to reduce the toxicity of the expressed heterologous protein against the host cells. As such, the hBD-l gene was fused to the DsbC- Tag of pET -40b(+), then introduced to L. lactis A 164. The transformants expressed an intracellular 35.6-kDa DsbC-hBD-l fusion protein that exhibited slight activity against the host cells, yet not enough to strongly inhibit the cell growth. To obtain the recombinant hBD-l, the DsbC-hBD-l fusion protein was purified by nickel-affinity column chromatography, and the DsbC-Tag removed by cleaving with enterokinase. The cleaved mature hBD-l exhibited strong bactericidal activity against E. coli JM109, indicating that the recombinant L. lactis A 164 produced a biologically active hBD-I. In addition, the recombinant L. lactis A 164 was also found to produce the same level of nisin Z as the wild-type.

Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets

  • Kim, Yunmi;Cha, Jung-Yul;Hwang, Chung-Ju;Yu, Hyung Seog;Tahk, Seon Gun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.157-167
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the clinical efficacy of polymer- and rhodium-coated wires compared to uncoated wires by measuring the frictional forces using self-ligation brackets. Methods: 0.016-inch nickel titanium (NiTi) wires and $0.017{\times}0.025$-inch stainless steel (SS) wires were used, and the angulations between the brackets and wires were set to $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$. Upper maxillary premolar brackets (Clippy-C$^{(R)}$) with a 0.022-inch slot were selected for the study and a tensile test was performed with a crosshead speed of 5 mm/min. The maximum static frictional forces and kinetic frictional forces were recorded and compared. Results: The maximum static frictional forces and the kinetic frictional forces of coated wires were equal to or higher than those of the uncoated wires (p < 0.05). The maximum static frictional forces of rhodium-coated wires were significantly higher than those of polymercoated wires when the angulations between the brackets and wires were set to (i) $5^{\circ}$ in the 0.016-inch NiTi wires and (ii) all angulations in the $0.017{\times}0.025$-inch SS wires (p < 0.05). The kinetic frictional forces of rhodium-coated wires were higher than those of polymer-coated wires, except when the angulations were set to $0^{\circ}$ in the 0.016-inch NiTi wires (p < 0.05). Conclusions: Although the frictional forces of the coated wires with regards to aesthetics were equal to or greater than those of the uncoated wires, a study under similar conditions regarding the oral cavity is needed in order to establish the clinical implications.