• 제목/요약/키워드: NiTi hand files

검색결과 9건 처리시간 0.023초

An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files

  • Gehlot, Paras Mull;Manjunath, Vinutha;Manjunath, Mysore Krishnaswamy
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.6-11
    • /
    • 2016
  • Objectives: The purpose of this in vitro study was to evaluate the accuracy of working length (WL) determination of four electronic apex locators (EALs), namely, Root ZX (RZX), Elements diagnostic unit and apex locator (ELE), SybronEndo Mini Apex locator (MINI) and Propex pixi (PIXI) using Stainless steel (SS) and nickel-titanium (NiTi) hand files. The null hypothesis was that there was no difference between canal length determination by SS and NiTi files of 4 EALs. Materials and Methods: Sixty extracted, single rooted human teeth were decoronated and the canal orifice flared. The actual length (AL) was assessed visually, and the teeth were embedded in an alginate model. The electronic length (EL) measurements were recorded with all four EALs using SS and NiTi files at '0.5' reading on display. The differences between the AL and EL were compared. Results: The results obtained with each EAL with SS and NiTi files were compared with AL. A paired sample t test showed that there was a statistical significant difference between EAL readings with SS and NiTi files for RZX and MINI (p < 0.05). The accuracy of RZX, ELE, MINI and PIXI within ${\pm}0.5 mm$ of AL with SS/NiTi files were 93.3%/70%, 90%/91.7%, 95%/68.3%, and 83.3%/83.3%, respectively. Conclusions: The results of this study indicate that Root ZX was statistically more accurate with NiTi files compared to SS files, while MINI was statistically more accurate with SS files compared to NiTi files. ELE and PIXI were not affected by the alloy type of the file used to determine WL.

레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구 (A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS)

  • 양인석;강인철;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.393-401
    • /
    • 2005
  • 본 연구는 형태 및 재질이 동일한 엔진구동형 ProTaper파일과 수동형 ProTaper파일을 이용하여 레진모형근관을 성형한 후 근관형태 변화를 비교 분석하고자 시행되었다. 본 연구에서는 레진모형근관으로 총 40개의 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다. 근관 성형 기구로는 엔진구동형 Ni-Ti 파일로 $ProTaper^{TM}$, 수동형 Ni-Ti 파일로 $ProTaper^{(R)}$ For Hand Use를 사용하였다. 사용된 레진모형근관과 파일의 종류에 따라 10개씩 4개의 그룹으로 나누어 근관성형을 시행하였다. 근관 성형 전$\cdot$후 이미지를 스캐너 (Color scanner, UMAX Technologies, Inc., USA)를 이용하여 얻은 후. Photoshop 7.0 프로그램 (Adobe System Inc., USA)을 이용하여 이미지를 중첩하였다. 이미지 분석 프로그램 (Image-$Pro^{(R)}$ Plus, Media Cybernetic, USA)을 이용하여 치근단 쪽에서부터 0, 1, 2, 3, 4, 5, 6 및 7 mm 수준에서 근관 성형에 따른 근관의 내측 및 외측 폭경의 변화량, 근관 총폭경의 변화량, 근관 중심축의 변위량을 측정하였다. 또한 근관 성형 시간을 기록하였다. 두 기구 사이의 유의성 검정을 위해 독립 표본 t-검정을 시행하여, 근관 성형 시 수동형 ProTaper 파일이 엔진구동형 ProTaper 파일에 비해 근관 중심축의 변위가 유의하게 덜 일어나며 근관의 원래 형태를 더욱 잘 유지할 수 있지만, 근관 성형시간은 길어질 수 있다는 결론을 얻었다.

회전식 nickel-titanium file을 이용한 유치의 근관치료 (ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES)

  • 서주희;이광희;김대업;양계식
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.620-625
    • /
    • 2001
  • 유치의 근관치료에서 치수절제술은 실활된 유치를 치열궁내에 유지하기 위해 치관과 근관부분의 괴사된 치수조직을 완전하게 제거하는 것을 말한다. 이 술식은 감염된 치수의 세균을감소시키는 것을 목적으로 하며, 다양하고 불규칙한 유치 근관의 형태가 주된 장애 요소로 작용한다. 더욱이 비협조적인 어린이의 경우에는 오랜 시간동안 정교한 시술을 하기가 곤란하다. 최근 들어 근관치료시에 회전식 기구를 이용하여 근관형성을 하는 장비들이 많이 개발되었으며 저속전기 모터에 회전식 NiTi file을 이용한 술식이 많이 사용되고 있다. 본 증례에서는 회전식 NiTi file과 전기모터를 이용하여 유구치의 근관치료를 시도하였다. 치수강을 개방하고 치관부 치수를 제거한 후 잠정적 작업장을 측정하였으며 적절한 NiTi file을 선택하여 잠정적 작업장까지 crown-down방법으로 점차적으로 형성하였다. 수용 file로 근단부 도달 및 성형을 하고 전체적인 마무리를 하여 Vitapex로 충전하여 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향 (THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE)

  • 임형태;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향 (THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL)

  • 오현정;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

만곡 근관에서 삼각 혹은 장방형 단면 구조의 니켈-티타늄 파일 응력 분포에 관한 3차원 유한요소 연구 (STRESS DISTRIBUTION FOR NITI FILES OF TRIANGULAR BASED AND RECTANGULAR BASED CROSS-SECTIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 김현주;이찬주;김병민;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 이 연구의 목적은 3차원 유한요소 모형 분석을 이용하여 삼각 대칭형과 5형태의 단면 및 변형된 사각 형태인 장방형 단면으로 분류되는 네 종류의 니켈티타늄 파일이 만곡 근관 적용 시의 응력 분포를 비교하는 것이다. 삼각 대칭형 단면 구조의 ProFile #30 / .06과 Heroshaper #30 / .06, 장방형 단면구조의 Mtwo #30 / .05와 NRT #30/ .06 파일을 마이크로컴퓨터 단층촬영을 하고 reverse engineering을 통하여 파일의 구조를 얻고 삼차원 유한요소모형을 제작하였다. 모형 근관 내에서 파일이 근관장끝까지 진입하여 회전할 때 발생하는von Mises 응력 분포 및 파일의 제거후의 잔류 음력의 분포양상을 ABAQUS 프로그램을 이용하여 비교하였다. 근관 내 회전 시에 발생하는 응력을 관찰하였을 때 NRT 파일에서 가장 큰 응력을 나타냈으며, 각 파일에서의 최고 응력과 최저 응력을 비교하였을 때 Mtwo파일에서 가장 큰 차이가 나타났다. 응력의 내부 분포 경향을 보았을 때 장방형 구조의 단면을 가진 Mtwo 및 NRT 파일에서 불연속적인 응력의 집중 부위가 관찰되었으며, 근관 외부로 파일을 제거하여 탄성 회복이 일어난 후의 잔류 응력도 NRT 파일에서 가장 높게 나타났다. 이상의 결과로 유추할 때, 삼각대칭 단면 구조를 가진 파일보다 S-형태의 단면과 변형된 사각 형태의 단면 등의 장방형 단면 구조의 파일이 파절의 위험성이 더 클 것으로 사료된다.

수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향 (EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE)

  • 이철환;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

도말층이 가온 수직가업 근관 충전후 치근단 누출에 미치는 영향 (EFFECT OF SMEAR LAYER ON THE APICAL LEAKAGE OF WARM VERTICAL CANAL FILLING)

  • 권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.561-574
    • /
    • 1998
  • 본 연구는 근관형성시 생성되는 도말층의 존재가 System-B를 이용한 가온 수직가압충전 후의 미세누출에 미치는 영향을 관찰하고자 시행되었다. 최근에 발거된 20개의 상악전치를 이용하여 Ni-Ti 전동화일의 한 종류인 Quantec series 2000$^{TM}$(Tycom, USA) 과 수통 K-화일로 근관형성시 생성되는 도말층의 차이와 EDTA 용액 및 EDTA/차아염소산나트륨 용액의 2종 세척액에 따른 도말층의 제거양상을 주사전자현미경으로 관찰하였다. 44개의 상악전치를 이용하여 System-B를 이용한 가온 수직가압충전후의 미세누출의 정도를 근관형성시 생성되는 도말층의 존재유무에 따라 색소침투법과 치아투명화법을 이용하여 비교한 결과 다음과 같다. ${\cdot}$ 수동 K-화일이나 전동 Ni-Ti 화일로 근관형성한 군 모두에서 EDTA 용액을 사용한 군은 도말층이 완전히 제거되어 상아세관이 깨끗하게 개방되었지만, 차아염소산나트륨 용액만 사용한 군은 근관의 대부분이 도말층으로 덮혀 있었고 개방된 상아세관은 발견할 수 없었다. ${\cdot}$ 수동 K-화일 군과 전동 Ni-Ti 화일 군 사이에는 생성된 도말층의 차이를 관찰할 수 없었다. ${\cdot}$ EDTA 용액을 이용하여 도말층을 제거한 경우와 차아염소산나트륨 용액만을 사용한 경우간의 비교에서는, sealer를 사용했을 때에는 도말층을 제거한 경우가 유의하게 적은 색소 침투를 나타냈으며(p<0.01), sealer를 사용하지 않았을 때에는 EDTA 용액과 차아염소산나트륨 용액으로 세척한 경우가 다소 적은 색소 침투를 나타냈으나 통계적 유의성은 없었다(p>0.05). ${\cdot}$ EDTA 용액를 이용하여 도말층을 제거한 후 sealer사용 유무에 따른 비교에서는 sealer를 사용한 경우에서 통계적으로 유의하게 적은 색소침투를 나타냈다(p<0.01). ${\cdot}$ EDTA 용액을 사용하지 않고 차아염소산나트륨 용액만으로 근관형성한 후 sealer사용 유무에 따른 비교에서는 sealer를 사용한 경우에서 통계적으로 유의하게 적은 색소 침투를 보였다(p<0.01).

  • PDF

근관형성법이 근관잔Δ사의 치근단 정출에 미치는 영향 (EFFECT OF CANAL PREPARATION METHODS ON THE APICAL EXTRUSION OF DEBRIS)

  • 박주명;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.399-407
    • /
    • 1999
  • 근관 형성중 잔사의 치근단 정출은 치근단 조직의 반응을 유발하여 동통과 부종을 일으키며 치유를 지연시킬 수 있다. 본 연구의 목적은 수종의 기구와 방법을 사용하여 근관을 형성하고 이에 따른 근관 잔사의 치근단 정출량을 비교함으로써 잔사의 정출을 최소화 할 수 있는 기구 조작법을 알아보고자 하는 것이다. 120개의 발거된 사람의 하악 절치에서 근관형성중 치근단으로 정출되는 잔사의 양을 비교하였다. 첫 번째 실험에서는 40개의 치아를 10개씩 4군으로 나누어 2.52% 치아염소산나트륨용액으로 근관을 세척하면서 다음의 4방법 중 하나를 이용하여 근관을 형성하였다. 수동 스테인레스 스틸 K-화일을 이용하여 step-back technique, crown-down pressureless technique으로 근관을 형성하였고 전동 니켈 티타늄 기구로는 Quantec SC series 2000과 Profile .04 taper series 29를 이용하여 근관을 형성하였다. 두 번째 실험에서는 80개의 치아를 16개씩 5군으로 나누고 근관 세척에 의한 잔사의 치근단 정출 영향을 배제하고자 근관 세척을 시행하지 않고 근관을 형성하였다. 이 때에는 첫 번째 실험의 방법중 Quantec SC series 2000 대신에 Quantec SC 및 Quantec LX를 이용하여 근관을 형성하였고 나머지는 첫 번째 실험과 동일하게 시행하였다. 각 치아로부터 정출되는 잔사를 용기에 모아 24 시간동안 건조시킨 후 전자 저울로 무게를 측정, 비교하여 다음과 같은 결과를 얻었다. 근관 세척을 시행한 경우와 시행하지 않은 경우 공히 step-back technique을 사용한 군에서는 다른 군에 비해 현저히 많은 량의 치근단 정출 잔사가 나타났다. 그러나, crown-down technique을 이용하여 근관 형성한 군과 수종의 Ni-Ti 파일을 이용하여 전동으로 근관 형성한 군들 사이에는 정출 잔사량에 유의한 차이가 나타나지 않았다. 따라서, 본 실험에 사용된 수동 및 전동 기구의 종류는 근관 잔사의 치근단 정출에 영향을 미치지 않는 것으로 생각되며, 근관잔사의 치근단 정출을 최소화하기 위해서는 수동 및 전동 기구 공히 step-back 방법에 의한 filing 동작보다는 crown-down technique의 reaming 동작을 사용하여 근관을 형성하는 것이 바람직하다고 사료된다.

  • PDF