• Title/Summary/Keyword: Ni-Ti 파일

Search Result 52, Processing Time 0.036 seconds

Mechanical and geometric features of endodontic instruments and its clinical effect (근관치료 기구의 기계 형태적 특성과 이에 따른 임상적 영향 고찰)

  • Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Introduction: The aim of this paper is to discuss the mechanical and geometric features of Nickel-titanium (NiTi) rotary files and its clinical effects. NiTi rotary files have been introduced to the markets with their own geometries and claims that they have better ability for the root canal shaping than their competitors. The contents of this paper include the (possible) interrelationship between the geometries of NiTi file (eg. tip, taper, helical angle, etc) and clinical performance of the files as follows; - Fracture modes of NiTi rotary files - Non-cutting guiding tip and glide path - Taper and clinical effects - Cross-sectional area and clinical effects - Heat treatments and surface characteristics - Screw-in effect and preservation of root dentin integrity - Designs for reducing screw-in effect Conclusions: Based on the reviewed contents, clinicians may have an advice to use various brands of NiTi rotary instruments regarding their advantages which would fit for clinical situation.

치과용 Ni-Ti 파일의 피로파절특성에 미치는 표면개질의 영향

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.76-76
    • /
    • 2017
  • Ni-Ti 파일은 근관치료 시 근관형성에 사용되며 근관계 내 조직 잔사와 세균 을 포함한 모든 내용물을 제거하고 미세누출이 생기지 않도록 성공적으로 근관충전을 할 수 있는 근관의 형태를 만드는데 사용된다. Ni-Ti 파일은 수동형 파일처럼 날이 풀어지거나 예각으로 꺾이는 등 시각적으로 나타나는 파일의 피로도나 손상정도를 인지하기 어려워 파일이 근관 내에서 부러지는 것을 막기가 어렵다. Ni-Ti 파일은 육안으로 관찰 할 수 있는 구부러짐이나 풀림 등의 소성변형 없이 기구의 탄성한계 내에서 갑작스럽게 파절되는 경우가 있는데, 이는 만곡 근관 내에서 기구가 회전하는 동안 만곡의 안쪽에는 압축응력이, 만곡의 바깥쪽에는 인장응력이 반복적으로 가해짐으로써 파절의 표면에 미세 파절과 균열이 발생하고 전파되어 결국 피로파절(fatigue fracture)을 야기하게 된다. 또한 Ni-Ti파일이 반복응력을 받으면 균열이 형성되면서 파절이 야기되며 연성파절(ductile fracture) 양상을 나타낸다고 보고하였다. Ni-Ti 파일을 이용한 피로파절에 대한 이전의 연구에서는 파일의 직경이나 경사도 (taper), 단면 형태 및 회전속도, 표면결함 등이 파절에 영향을 미친다고 보고되고 있다. 사용하지 않은 Ni-Ti파일을 구부려 응력을 가 한 상태에서 주사전자현미경으로 관찰한 결과 기계 가공 과정에서 발생한 균열, 미세 결함, 긁힌 자국 및 불균질성 등이 원인으로 알려져 있다. 따라서 본 연구발표에서는 표면결함을 최소화하고 기구의 회전응력 하에서 피로파절저항성을 향상시키기 위한 방법에 대하여 알아보고자 한다.

  • PDF

Effects of TiN/Ti and ZrN/Ti Multilayer Coating on the Surface Characteristics of Dental Ni-Ti Alloy Files (치과용 Ni-Ti합금파일의 표면거동에 미치는 TiN/Ti 및 ZrN/Ti 다층막 코팅의 영향)

  • Gang, Ho-Min;Hwang, Ho-Gil;Jang, Seung-Hyeon;Jeong, Yong-Hun;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.64-65
    • /
    • 2008
  • 본 연구에서는 임상적으로 사용후 파절된 Ni-Ti파일의 표면 거동을 조사해보고 피로파괴수명 연장을 위하여 표면에 TiN/Ti 및 ZrN/Ti를 다층막으로 코팅한 후 표면의 특성을 조사하였다.

  • PDF

Electrochemical Characteristics of TiN/Ti and ZrN/Ti Multilayer Coated Dental Ni-Ti Alloy Files (TiN/Ti 및 ZrN/Ti 다층막 코팅된 Ni-Ti합금파일의 전기화학적 특성)

  • Park, Jun-Mo;Hwang, Ho-Gil;Jang, Seung-Hyeon;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.66-67
    • /
    • 2008
  • 본 연구에서는 코팅된 Ni-Ti파일의 이온용출을 조사하기 위하여 표면에 형성된 TiN/Ti 및 ZrN/Ti다층막의 구강유사액에서 표면의 부식특성을 조사하였다.

  • PDF

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

Efficacy of retreatment NiTi files for root canals filled with calcium silicate-based sealer (칼슘실리케이트 계열 실러로 충전한 근관에서 재치료용 NiTi 파일의 효율성)

  • Jae-Yun, Hyun;Kyung-Mo, Cho;Se-Hee, Park;Yoon, Lee;Yoon-Joo, Lee;Jin-Woo, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.213-221
    • /
    • 2022
  • Purpose: The efficacy of the amount of sealer in the root canal and two retreatment NiTi file systems in removing filling materials. Materials and Methods: Extracted premolars with a single root canal were selected for this study. After access opening and root canal preparation up to size #40/.06, the specimens were randomly divided into four groups. Gutta percha (GP) tapers of .06 or .04 were used for each group and filled using a single-cone filling technique with CeraSeal, a calcium silicate-based sealer. Each group was retreated either using the ProTaper Universal Retreatment System (PTUR) or the Hyflex Remover (HR). The time taken to remove the filling material, the amounts of apically extruded debris, and canal cleanliness were measured and compared. Results: The amount of sealer did not affect the efficiency when removing the filling materials. However, the filling material was removed faster in the HR group than in the PTUR group. Two types of NiTi files showed similar retreatment effects in the amounts of apically extruded debris and in the degree of canal cleanliness. Conclusion: The amount of sealer in canal filling had no significant effect on retreatability. Retreatment with HR removed filling materials is faster than PTUR. There was no difference in other removal efficiencies according to the type of retreatment NiTi file.

A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS (레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구)

  • Yang, In-Seok;Kang, In-Chol;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.393-401
    • /
    • 2005
  • The purpose of this study was to compare the canal configuration after shaping by ProTaper rotary files and ProTaper hand files in resin simulated canals. Forty resin simulated canals with a curvature of J-shape and S-shape were divided into four groups by 10 blocks each Simulated root canals in resin block were prepared by ProTaper rotary files and ProTaper hand files using a crown-down pressureless technique All simulated canals were prepared up to size $\#25$ file at end-point of preparation. Pre- and post-instrumentation images were recorded with color scanner. Assessment of canal shape was completed with an image analysis program. Measurements were made at 0, 1, 2, 3, 4, 5, 6 and 7 mm from the apex. At each level, outer canal width, inner canal width, total canal width, and amount of transportation from original axis were recorded. Instrumentation time was recorded. The data were analyzed statistically using independent t-test. The result was that ProTaper hand files cause significantly less canal transportation from original axis of canal body and maintain original canal configuration better than ProTaper rotary files, however ProTaper hand files take more shaping time.

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.