• Title/Summary/Keyword: Ni-S

Search Result 2,431, Processing Time 0.034 seconds

Cell Properties for SOFC Using Synthesized Powder of Electrolyte LSGM System and Cathode LSM System (LSGM 전해질과 LSM 양극의 합성분말을 이용한 SOFC 단위전지의 특성)

  • Lee, Mi-Jai;Nam, Jeong-Hee;Choi, Byung-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.4
    • /
    • pp.359-366
    • /
    • 2002
  • The purpose of this study is to investigate the properties of LSGM electrolyte and LSM cathode. The unit cell based on the optimum conditions and processing for high performance was fabricated and measured. The single phase of $LaGaO_3$ was obtained on sintering at $1500^{\circ}$ for 6h with composition of $(La_{0.85}Sr_{0.15})(Ga_{0.8}Mg_{0.2})O_{3-\delta}와 (La_{0.8}Sr_{0.2})(Ga_{0.8}Mg_{0.2})O_{3-\delta}$ and $(La_{0.85}Sr_{0.15})(Ga_{0.8}Mg_{0.2})O_{3-\delta}$. The grain size of the sintered body was about $10∼30{\mu}m$ and electrical conductivity was 0.13 S/cm measured at $800^{\circ}$. The single phase of $LaMnO_3$ structure in $(La1-xSrx)MnO_3$ system was obtained at x=0∼0.2 and the particle size of the synthesized powder was about 40 nm. The unit cell was prepared by firing at $1200^{\circ}$ for 1h with $(La_{0.9}Sr_{0.1})MnO_3$ cathode and 0.9NiO-0.1YSZ anode screen-printed on surfaces of $(La_{0.8}Sr_{0.2})(Ga_{0.8}Mg_{0.2})O_{3-\delta}$ electrolyte. The grain size of the electrode was close to $1{\mu}m$ and the electrode had porous structure. The maximum power density of unit cell showed $0.3W/cm^2$ at $800^{\circ}$.

Catalytic CVD-Kinetics of Pyrolytic Carbon and SiC on the Stainless Steel Stent (Stainless Steel Stent에 Pyrolytic Carbon과 SiC의 촉매적 CVD-Kinetic연구)

  • 이보성;이무용
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.30-33
    • /
    • 2000
  • 최근 국내에서도 관 동맥 질환 환자의 수가 급증하고 있으며, 관 동맥 질환의 치료 방법인 관 동맥 성형 술은 관 동맥 stent의 도입에 의하여 보편화되어 국내에서 년간 5000개 이상의 stent가 시술되고 있다. 그러나 stent는 고가(1,200천원/개)로 전량 수입에 의존하고 있으며, 시술 후 사망까지 이를 수 있는 혈전에 의한 급성 페쇠와 재 협착이 문제점이다. 이를 위한 한가지 방법이 생체 적합성이 뛰어난 복합 stent의 개발인데 SiC나 Carbon을 coating한 stent는 시술 후 혈전 형성을 억제하는 것으로 알려져 있다. 특히 가장 순수한 Pyrolytic carbon은 hemocompatibility가 탁월하고 기밀 성이기 때문에 본 연구에서 그의 CVB-Kinetics를 연구코저 하는 것이다. methane으로부터 pyrolytic carbon의 CVD는 온도에 따라서 다양한 구조를 가지며 따라서 그의 mechanism도 다양하다는 것은 잘 알려져 있다. 더구나 광간(균질)반응과 표면(불균질)반응의 정량적 관계에 따라서도 다르다는 것도 확인되었다. 그러나 stainless steel 316L로 만든 stent는 12 - 15 %의 Ni과 2%의 Mo을 함유해서 금속성을 잃지 않는 저온(600℃)에서도 pyrolytic carbon의 속매적 CVD가 가능함을 그리고 SiC의 코팅에 적합한 buffer layer 역할을 함을 확인하였다. 그리하여 본 연구는 반응기 설계에 필요한 저온 촉매적 pyrolytic carbon의 CVD-kinetics의 연구결로 그의 mechanism과 함께 rate law 식을 유도, 확인하였으며 600℃, 90kPa에서 P/sub ch4//P/sub H2/=5:1과 체류시간 1.8 sec가 최적임을 발견하였다. 이때 석출속도 11.2 g-mol/g-cat.h 혹은 두께속도로 73 nm/sec를 나타내었다.메타놀-물 (1 : 1) 유출액에서 $(0.80\;{\mu}g)$ 검출되었다. 하면 morey eel내장에서 얻은 독물질도 DEAE-셀루로즈에서 ST-1 과 ST-2로 나누어지며, 이 ST-1의 TLC, HPLC 및 알루미나 컬럼상의 거동이 파랑비늘돔에서 얻은 ST-1의 그것과 같으므로 scaritoxin으로 보고한 ST-1은 ciguatoxin의 형태인 less polar cigutoxin (LPCTX) 으로 생각된다.에서 각각 대조구의 57, 413 및 315% 증진되었다. 거품의 열안정성은 15분 whipping시, pH 4.0(대조구, 30.2%) 및 5.0(대조구, 23.7%)에서 각각 $0{\sim}38.0$$0{\sim}57.0%$이었고 pH 7.0(대조구, 39.6%) 및 8.0(대조구, 43.6%)에서 각각 $0{\sim}59.4$$36.6{\sim}58.4%$이었으며 sodium alginate 첨가시가 가장 양호하였다. 전체적으로 보아 거품안정성이 높은 것은 열안정성도 높은 경향이며, 표면장력이 낮으면 거품형성능이 높아지고, 비점도가 높으면 거품안정성 및 열안정성이 높아지는 경향이 있었다.protocol.eractions between application agents that are developed using different languages. Dynamic agent invocation is accomplished by Java Native Interface(JNI) that links two heterogeneous methods, and by KQML language interface that facilitates the communications between heterogeneous agents. This scheme of dyna

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

Interview Survey of Elementary School Students' Nutrition Education and Practice (면접조사를 통한 초등학생의 영양교육 실태 및 실천도 조사)

  • Oh, Yu-Jin;Lee, Young-Mee;Kim, Jung-Hyun;Ahn, Hong-Seok;Kim, Jeong-Weon;Park, Hae-Ryun;Seo, Jung-Sook;Kim, Kyung-Won;Kwon, O-Ran;Park, Hye-Kyoung;Lee, Eun-Ju;Sung, Huy-Ni
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.4
    • /
    • pp.499-509
    • /
    • 2008
  • This study investigated the experience and practice of elementary school students on nutrition education. The data were collected from 217 male and female students attending 5-6th grade elementary schools in Seoul and Kyunggi-Do from March to June 2007, interviewing face to face by a nutrition teacher and 3 interns of a nutrition teacher. The results were as follows: 86.5% of the subjects learned about 'Table etiquette', 'Reasons for eating fruits and vegetables'(78.7%), 'Food waste and environment'(72.3%), 'Healthy snacks'(55.7%), 'Food sanitation'(52.3%), 'Food culture of foreign countries'(48.1%). Nutrition education experience was significantly different by gender. A total of 43.5% boys responded that they never learned about 'basic food preperation'(p<0.01). They had learned 'Nutrients for body' and 'Food waste and environment' in school, 'Healthy weight loss', 'Food culture of foreign countries', 'Food circulation' on television, Most content('Table etiquette', 'Simple cooking', 'Food sanitation', 'Eating behaviors for health', 'Reasons for eating fruits and vegetables', 'Healthy snacks') was learned from parents. The practice after nutrition education was higher in 'Table etiquette'(2.14), 'Eating fruits and vegetables'(2.07) than others compared with education experience. The most reason of non-practice on nutrition information was 'Troublesome'. In 'Nutrients for body', a boy answered 'Difficult for practice' 20.0%, a girl answered 'Difficult to understand' 32.6%, showing a significant difference between the gender groups(p<0.001). They remembered the 'Nutrients for body'(49.6%), 'Food sanitation'(44.5%) because of 'important content', 'Basic food preparation'(40.6%), 'Food culture of foreign countries'(36.3%) because of 'interesting content', 'Healthy weight loss'(52.0%), 'Eating behavior for health'(44.5%) and 'Healthy snacks'(33.7%) because of 'need for my health'.

Preparation of Poly(propylene) Membrane Supported Gel Electrolyte Membranes for Rechargeable Lithium Ion Batteries through Thermal Polymerization of Di(ethylene glycol) Dimethacrylate (Di(ethylene glycol) Dimethacrylate의 열중합에 의한 Poly(propylene) 분리막으로 지지한 리튬이온 이차전지의 겔 전해질막 제조)

  • Yun, Mi-Hye;Kwon, So-Young;Jung, Yoo-Young;Cho, Doo-Hyun;Koo, Ja-Kyung
    • Membrane Journal
    • /
    • v.20 no.3
    • /
    • pp.259-266
    • /
    • 2010
  • Porous poly(propylene) supported gel polymer electrolytes (GPE) were synthesized by thermal polymerization of DEGDMA [Di(ethylene glycol) dimethacrylate] in electrolyte solutions (1 M solution of $LiPF_6$ in EC/DEC 1 : 1 mixture) at $70^{\circ}C$. AC impedance spectroscopy and cyclic voltammetry were used to evaluate its ionic conductivity and electrochemical stability window of the GPE membranes. Lithium ion battery (LIB) cells were also fabricated with $LiNi_{0.8}Co_{0.2}O_2$/graphite and GPE membranes via thermal polymerization process. Through the thermal polymerization, self sustaining GPE membranes with sufficient ionic conductivities (over $10^{-3}\;S/cm$) and electrochemical stabilities. The LIB cell with 5% monomer showed the best rate-capability and cycleability.

Development for the Waste Plastics Process (폐플라스틱의 재활용 기술)

  • 여종기
    • Resources Recycling
    • /
    • v.6 no.2
    • /
    • pp.22-28
    • /
    • 1997
  • In recent yean thc problem of wastc plastics arc greatly incrcascd with ihe result uf lndushial growth. As a rcsult the amount of wastc plaslics in domestic area is appraxhnately 2,300,000 t<~nin 1996 base and contmuously increasing more than 12% cvcry ycar. Thc disposal way of these waste plastics arc dlLl malnly rely~ng on landill1 or partially incinuralion So that it hss become a senous social problem due to the second envirnmentd pollution. The tcchnologics iar prducing oil from the waste plastics have hccn dcvelopcd far along pennd and currently some of them are in a commercialiration stage Pyrolysis process in one of the major process m heating waslc plaslics bul still has some restlichons for the cammcrc~dizatian duc lo 11s emnom~cal problems assaciated with a systcmiltlc lecd collcctionidispnsJ ways. Cansldenng cnvaomcnld problems, thc inclease m the charge for waste matcds trcatmcnt and thc lmlitarion ni disposal area, it is inteicstcd that the wastc plastics treabncnt by pyrolysn. which would be the safest and the most eilic~ent process for cnnvcrting fecd wastc to rc-usablc rcsourccs. would he predomhant m ihe near h~lurc Thc shldy aims inr the development of haslc ted~nolagy for scaling up to a com~nercial sire through pyrolys~s process which is cnnduclcd under the absence of air. Furthern~orc the waste plastics can be recycled as iual gas or oil wilhout harmful effects in enviroment, The waste w e d plastics arc pyrolyzed in (he fluidized bcd rcaclor under continuous way and thc ail ylcld gives approx~marcly 47 4%.

  • PDF

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Examination of Soil Contamination Status and Improvement Strategies within Urban Development Projects (도시개발사업 내 토양 오염 현황과 개선 방안 고찰)

  • Heo, Sujung;Lee, Dong-Kun;Kim, Eunsub;Jeon, Seong-Woo;Jin, Zhiying
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.27 no.3
    • /
    • pp.45-56
    • /
    • 2024
  • Heavy metals emitted from urban development do not decompose in the soil and remain for long periods, continually impacting the environment. Since the mid-1990s, there has been increasing societal concern in South Korea regarding soil contamination, prompting various legislative revisions to reduce pollution. This study utilizes the Environmental Impact Assessment Support System (EIASS) to investigate projects in the metropolitan area that have exceeded the Ministry of Environment's soil contamination concern levels from 1989 to 2022 and to examine improvements in the environmental impact assessment (EIA) process. The results reveal that the average concentrations of nine contaminants-cadmium (Cd), copper (Cu), arsenic (As), mercury (Hg), lead (Pb), hexavalent chromium (Cr6+), zinc (Zn), nickel (Ni), and fluoride (F)-have all increased over the years. Among these, Zn had the highest relative proportion, with 37.5% of the 40 sites exceeding environmental concern levels. Investigation of 19 specific projects at these exceedance sites showed that only 7 had documented analyses of contamination causes and remediation plans, and just one had contracted additional remediation services, though results from these efforts were found to be lacking. Furthermore, since 2019, a significant proportion of these sites were involved in residential developments, likely due to government initiatives in new city development and extensive housing supply plans. This research emphasizes the importance of public disclosure of the processes and outcomes of remediation efforts on historically contaminated soils prior to project development. It discusses improvements to the EIA by reviewing current legislation and international examples. The findings of this study are expected to heighten public awareness about heavy metal contamination and enhance transparency in soil remediation efforts, contributing to sustainable environmental management and development.

Biosorption and Desorption of Heavy Metals using Undaria sp. (미역 폐기물의 중금속 흡탈착 특성)

  • Cho, Ju-Sik;Park, Il-Nam;Heo, Jong-Soo;Lee, Young-Seak
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.92-98
    • /
    • 2004
  • The adsorption and desorption of Pb, Cd, Co, Zn, Cr, Co, Ni, and Mo on the waste Undaria sp. were studied. Except for Pb. the mono adsorption rate for all heavy metals were lower than that of the heavy metals mixed. However, the adsorption capacity of the heavy metals by 1g of biosorption, in mixed heavy metals increased According to FT-IR analysis of the biosorbent after heavy metal biosorption, the replacement of the functional group by the heavy metals ions could be confirmed and the inverted peaks became larger after heavy metals adsorption. The adsorption equilibrium of heavy metals was reached in about 1 hour. The equilibrium parameters were determined based on Langmuir and Freundlich isotherms. The affinity of metals on the biosorbent decreased in the following order: Pb>Cu>Cr>Cd>Co. The desorption rate decreased in the following sequence: NTA>$H_2SO_4$>HCl>EDTA. The desorption rate of heavy metals by NTA increased with increase in the concentration from 0.1 to 0.3% but the desorption rate became constant beyond 0.3%. Therefore, it represented that desorption rate of heavy metals was suitable under optimized condition ($30^{\circ}C$, pH 2 and 0.3% NTA solution) and was fast with 80% or more the uptake occurring within 10 min of contact time.

Preliminary Study on the Ultramafic Rocks from the Chungnam Province, Korea (충남지역에 분포하는 초염기성암의 기원규명을 위한 기초연구)

  • Wee, Soo-Meen;Choi, Seon-Gyu;So, Chil-Sup
    • Economic and Environmental Geology
    • /
    • v.27 no.2
    • /
    • pp.171-180
    • /
    • 1994
  • Several ultramafic bodies and ultramafic origin talc deposits are distributed in Chungnam province near the contact zone with Ogchun fold belt They occur as discontinued belt form with northeast trending, and most of them are more or less sepentinized. Major, trace, and rare earth elements analyses were made of the ultramafics from the study area to constrain their origin and genetic relationships. Compared to the primitive mantle estimates of privious workers, the correlations defined by the studied rock samples indicate similar Ni but very lower $Al_{2}O_{3}$, CaO and $TiO_{2}$ contents. It is inferred that source material of the studied rocks might be residual mantle which had undergone a large degree of partial melting event. The REE patterns show relatively flat to enriched in LREE (chondrite normalized La/Yb and Sm/Yb ratios are 1.1-5.2 and 1.2-1.6). Several alternative explaination are possible for LREE enrichment patterns in the studied ultramafic rocks such as 1) enrichment due to late stage alteration, 2) enriched pre-melting composition, and 3) mixing of two components. Based on the result, the LREE enrichment characteristic of the studied rocks might be result from the mixture of two geochemically distinct components; one is depleted residual mantle and the other component which determine the abundances of incompatible elements and responsible for the LREE enrichment.

  • PDF