• 제목/요약/키워드: Ni variation

검색결과 409건 처리시간 0.026초

A Study About Radionuclides Migration Behavior in Terms of Solubility at Gyeongju Low- and Intermediate-Level Radioactive Waste (LILW) Repository

  • Park, Sang June;Byon, Jihyang;Lee, Jun-Yeop;Ahn, Seokyoung
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.113-121
    • /
    • 2021
  • A safety assessment of radioactive waste repositories is a mandatory requirement process because there are possible radiological hazards owing to radionuclide migration from radioactive waste to the biosphere. For a reliable safety assessment, it is important to establish a parameter database that reflects the site-specific characteristics of the disposal facility and repository site. From this perspective, solubility, a major geochemical parameter, has been chosen as an important parameter for modeling the migration behavior of radionuclides. The solubilities were derived for Am, Ni, Tc, and U, which were major radionuclides in this study, and on-site groundwater data reflecting the operational conditions of the Gyeongju low and intermediate level radioactive waste (LILW) repository were applied to reflect the site-specific characteristics. The radiation dose was derived by applying the solubility and radionuclide inventory data to the RESRAD-OFFSITE code, and sensitivity analysis of the dose according to the solubility variation was performed. As a result, owing to the low amount of radionuclide inventory, the dose variation was insignificant. The derived solubility can be used as the main input data for the safety assessment of the Gyeongju LILW repository in the future.

증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발 (Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube)

  • 박덕근;유권상;이정기;손대락
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.9-15
    • /
    • 2008
  • 증기발생기 전열관에 생성되는 투자율변화에 의해 야기되는 신호왜곡 문제를 해결하기 위한 새로운 탐촉자를 개발하였다. 고리 1 호기 폐전열관에 생성된 자성상을 분리하여 자기이력곡선을 측정하였으며, 자성상이 생성되는 원인을 규명하기 위하여 고온 인장 시험을 수행하였다. 전산모사를 이용하여 탐촉자의 자정상 탐지조건을 결정하였으며, 디지털 신호전송을 위하여 신호처리용 전자회로를 소형화하여 탐촉자 속에 삽입하였다. 본 연구에서 개발된 신형 탐촉자를 이용하여 PVC 신호와 니켈 슬리빙 부위의 결함을 측정하였다. 신형 탐촉자는 보빈 탐촉자와 같이 고속으로 결함을 측정 할 수 있으며, 증기발생기 전열관의 탐상속도와 결함 탐지의 신뢰성을 증진시킬 수 있다.

Pathologic Response During Chemo-radiotherapy and Variation of Serum VEGF Levels Could Predict Effects of Chemo-Radiotherapy in Patients with Esophageal Cancer

  • Yu, Jing-Ping;Lu, Wen-Bin;Wang, Jian-Lin;Ni, Xin-Chu;Wang, Jian;Sun, Zhi-Qiang;Sun, Su-Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.1111-1116
    • /
    • 2015
  • Background: To investigate the relationship between pathologic tumor response to concurrent chemoradiotherapy and variation of serum VEGF in patients with esophageal cancer. Materials and Methods: Forty six patients with esophageal cancer who were treated with concurrent chemo-radiotherapy were enrolled. Endoscopic and pathologic examination was conducted before and four weeks afterwards. Serum level of VEGF was documented before, four weeks later and after chemo-radiotherapy. The relationship between pathologic response and the variation of serum level of VEGF and its influence on the prognosis were investigated. Results: Serum level of VEGF decreased remarkably during and after chemo-radiotherapy in patients whose pathologic response was severe (F=5.393, 4.587, P(0.05). There were no statistical differences of serum VEGF level before, during and after chemo-radiotherapy for patients whose pathologic response was moderate or mild. There were 18 (85.7%), 7 (53.8%) and 6 patients (50.0%) whose serum VEGF level dropped in the severe, moderate and mild group, respectively, with significant differences among these groups (p=0.046). Two year survival rates of patients with severe, moderate and mild pathologic response were 61.9%, 53.8% and 33.3% respectively, and no statistically difference between severe and mild group regarding OS (p=0.245) was tested. Conclusions: Tumor pathologic response during chemo-radiotherapy and the changes of serum VEGF lever could predict curative effects of chemo-radiotherapy in patients with esophageal cancer.

통계분석을 이용한 경기도 대기 중 미세먼지 및 중금속 분포 특성 (Distribution Characteristics of PM10 and Heavy Metals in Ambient Air of Gyeonggi-do Area using Statistical Analysis)

  • 김종수;홍순모;김명숙;김요용;신은상
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.281-290
    • /
    • 2014
  • This study was conducted to evaluate the distribution characteristics of $PM_{10}$ and heavy metals concentrations in the ambient air of Gyeonggi-do area by region and season from February, 2013 to March, 2014. The regression model for the prediction of formation characteristics and contamination degree of $PM_{10}$ and heavy metals by correlation analysis and regression analysis for using the multivariate statistical analysis was also established. The main wind direction during the investigation period was South East (SE) and West South West (WSW) winds, and the concentration of $SO_2$ at Ansan with industrial region showed 1.6 times higher than Suwon, Euiwang with residential region. The concentrations (median) of Pb, Cu and Ni at Ansan showed 3.2~4.5, 1.9~2.2 and 1.7~2.6 times respectively higher than those at Suwon. By the seasonal concentration variation, the concentrations of $PM_{10}$, Pb, Fe and As in winter and spring (December to May) showed 1.7, 1.9, 1.9 and 2.7 times respectively higher than those in summer and fall (June to November). As, Fe and $PM_{10}$ had a big difference by the seasonal factors, and Cu and Ni were evaluated to be influenced by the regional factors. From the results of correlation analysis among the target items, the correlation coefficient of PM and Mn had 0.82 (p/0.01) and that of Fe and Mn had 0.82 (p/0.01), which showed high correlation. And the correlation coefficients for $SO_2$ and Pb, CO and $PM_{10}$ were 0.66 (p/0.01) and 0.62 (p/0.01) respectively. The multiple linear regression models for $PM_{10}$, Pb, Cu, Cr, As, Ni, Fe and Mn were established by independent variables of CO, $SO_2$ and meteorological factors (wind speed, relative humidity). In the regression models, independent variable $SO_2$ was in cause-and-effect relationship with all dependent variables, and $PM_{10}$, Fe and Mn were influenced by CO and wind speed, and Pb, Cu, Ni and As had a main factor of $SO_2$.

국내 시중 유통 자연산 및 양식산 활어의 중금속 함량 (Heavy Metal Contents in Wild and Cultured Fishes from the Korean Coasts)

  • 목종수;심길보;이태식;송기철;이가정;김성길;김지회
    • 한국수산과학회지
    • /
    • 제42권6호
    • /
    • pp.561-568
    • /
    • 2009
  • We determined the contents of heavy metals in the muscle of wild and cultured fishes, collected from fish markets located in the eastern (Pohang), western (Gunsan), and southern (Tongyeong) coasts of Korea, from 2004 to 2005. As the results of monitoring the heavy metal contents in spring season, the wild fishes contained the range of Cd (0.01-0.08 mg/kg), Cr (ND-0.28 mg/kg), Cu (0.06-1.53 mg/kg), Hg (0.02-0.16 mg/kg), Mn (0.04-1.15 mg/kg), Ni (ND-0.09 mg/kg), Pb (0.03-0.41 mg/kg), and Zn (1.84-6.61 mg/kg). While for the cultured fishes, Cd (0.01-0.05 mg/kg), Cr (ND-0.17 mg/kg), Cu (0.05-0.61 mg/kg), Hg (0.02-0.13 mg/kg), Mn (0.03-0.17 mg/kg), Ni (ND-0.08 mg/kg), Pb (0.03-0.33 mg/kg), and Zn (2.06-6.20 mg/kg) were contained. In summer season, the contents of heavy metal in the muscle of the wild fishes were as follows: Cd (ND-0.11 mg/kg), Cr (0.01-0.37 mg/kg), Cu (0.21-1.31 mg/kg), Hg (0.01-0.11 mg/kg), Mn (ND-1.47 mg/kg), Ni (ND-0.26 mg/kg), Pb (0.06-0.48 mg/kg), and Zn (2.94-14.38 mg/kg). In comparison, the contents of heavy metal in the muscle of cultured fishes were Cd (ND-0.05 mg/kg), Cr (0.13-0.33 mg/kg), Cu (0.19-0.56 mg/kg), Hg (0.05-0.26 mg/kg), Mn (ND-0.14 mg/kg), Ni (ND-0.58 mg/kg), Pb (0.07-0.45 mg/kg), and Zn (2.43-7.53 mg/kg). Also the fall and the winter season, the heavy metal contents in the fishes showed almost similar with other season, however, Pb was lower and Zn was higher than both spring and summer season. The wild fishes contained the heavy metals a little more than the cultured fishes. We could not observe clear seasonal variation in the heavy metal contents of the fishes. The levels of Hg and Pb in all samples tested did not exceed the maximum permissible levels in the fishes set by the Korean Food & Drug Agency for safe human consumption.

GMR-SV 소자를 이용한 미크론 자성비드와 결합된 적혈구 검출 특성 연구 (Detection Characteristics of a Red Blood Cell Coupled with Micron Magnetic Beads by Using GMR-SV Device)

  • 이재연;김문종;이상석;이진규
    • 한국자기학회지
    • /
    • 제24권4호
    • /
    • pp.101-106
    • /
    • 2014
  • Dc 마그네트론 스퍼터링법으로 자기저항비 5.0 %와 자장감응도 1.5 %/Oe를 갖는 glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(2.3 nm)/NiFe(3 nm)/IrMn(12 nm)/Ta(5.8 nm) 다층구조 GMR-SV 박막을 증착하였다. 광 리소그래피 공정으로 적혈구 직경 크기인 $7{\mu}m{\sim}8{\mu}m$ 이내의 선폭인 GMR-SV 소자를 제작하였다. 직경 $1{\mu}m$ 크기인 여러 개의 자성비드가 결합된 적혈구를 자기저항비 1.06 % 자장감응도 0.3 %/Oe를 갖는 GMR-SV 소자에 떨어뜨려 -0.6 Oe 부근에서 약 $0.4{\Omega}$과 약 0.15 %의 변화를 관찰하였다. 본 연구로부터 미크론 크기의 선폭을 갖는 GMR-SV 소자가 자성비드를 결합한 적혈구내 헤모글로빈의 새로운 자성 특성을 분석하는 바이오센서로 활용할 수 있음을 보여주었다.

Heavy Metal Concentrations in the Mollusc Gastropod, Cipangopaludina chinensis malleata from Upo Wetland Reflect the Level of Heavy Metals in the Sediments

  • Kim, Heung-Tae;Kim, Jae-Geun
    • Journal of Ecology and Environment
    • /
    • 제29권5호
    • /
    • pp.453-460
    • /
    • 2006
  • Upo wetland is the largest inland wetland in Korea as Ramsar Convention Area. The purposes of the study were to investigate the levels of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn) in the sediment and Cipangopaludina chinensis malleata from three sites of the wetland and to assess the potential of the gastropod as a bioindicator for heavy metal levels. The gastropods were dissected into shell and soft tissue without the digestive and excretive organs. The levels of Cd, Cu and Pb were below the guideline of Soil Environment Conservation Act and the heavy metals except Cr were slightly different among the sites. Cd was higher in Upo site ($0.32{\mu}g/g$) than Sajipo site ($0.28{\mu}g/g$). Cu and Zn showed the highest value in Sajipo as $43.5{\mu}g/g\;and\;39.8{\mu}g/g$, respectively while the concentrations of Pb and Zn were the highest in Upstream as $58.8{\mu}g/g\;and\;138{\mu}g/g$, respectively. In the soft tissues and shells of the gastropod, the overall common trend in the concentrations of the heavy metals was revealed with the following order: Zn > Cu > Cr > Ni > Pb > Cd and Ni > Zn > Cr > Cu > Pb > Cd, respectively. Although the soft tissues exhibited higher concentrations of the heavy metals except Ni than the shell in the gastropod, the levels of Cd and Pb in the gastropod were generally below the restrictive values set up by Korea Food & Drug Administration. From Duncan's Multiple Range Test (DMRT) results, the concentrations of Pb and Zn in the sediments among the sites were reflected on the soft tissue (Pb) and the shell (Pb and Zn) of the gastropod in the same order. The lower value of coefficient of variation (CV) in Pb concentration of the shell than in that of the soft tissue supports the usefulness of the shell as a bioindicator for Pb pollution. Although the CV value in the shell was a little higher than in the soft tissue, DMRT results and the stability of incorporated Zn into the shell support the use of the shell of the gastropod as a potential bioindicator for long-term contamination of Zn.

적외선 센서용 [(Co1-xCux)0.2(Ni0.3Mn0.7)0.8]3O4 스피넬 박막의 구조 및 전기적 특성 (Structural and Electrical Properties of [(Co1-xCux)0.2(Ni0.3Mn0.7)0.8]3O4 Spinel Thin Films for Infrared Sensor Application)

  • 이귀웅;전창준;정영훈;윤지선;조정호;백종후;윤종원
    • 한국전기전자재료학회논문지
    • /
    • 제27권12호
    • /
    • pp.825-830
    • /
    • 2014
  • $[(Co_{1-x}Cu_x)_{0.2}(Ni_{0.3}Mn_{0.7})_{0.8}]_3O_4$ ($0{\leq}x{\leq}1$) thin films prepared by metal organic decomposition process were fabricated on SiN/Si substrate for infrared sensor application. Their structural and electrical properties were investigated with variation of Cu dopant. The $[(Co_{1-x}Cu_x)_{0.2}(Ni_{0.3}Mn_{0.7})_{0.8}]_3O_4$ (CCNMO) film annealed at $500^{\circ}C$ exhibited a dense microstructure and a homogeneous crystal structure with a cubic spinel phase. Their crystallinity was further enhanced with increasing doped Cu amount. The 120 nm-thick CCNMO (x=0.6) thin film had a low resistivity of $53{\Omega}{\cdot}cm$ at room temperature while the Co-free film (x=1) showed a significantly decreased resistivity of $5.9{\Omega}{\cdot}cm$. Furthermore, the negative temperature coefficient of resistance (NTCR) characteristics were lower than $-2%/^{\circ}C$ for all the specimens with $x{\geq}0.6$. These results imply that the CCNMO ($x{\geq}0.6$) thin films are a good candidate material for infrared sensor application.

Electric Properties of Step-up Piezoelectric transformer by dimension variation

  • Joo, Hyeon-Kyu;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung;Vo, Vietthang
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.103-103
    • /
    • 2009
  • In this study, in order to develop high power piezoelectric transformer, we compared the piezoelectric transformers dimension. The basic composition of piezoelectric ceramics is ternary $0.01Pb(Ni_{1/3}Nb_{2/3})O_3-0.08Pb(Mn_{1/3}Nb_{2/3})O_3-0.91Pb(Zr_{0.505}Ti_{0.495})O_3$. The voltage step up ratio of piezoelectric transformer showed the maximum value at the near of 81 kHz and increased according to the increase of load resistance.

  • PDF

패턴된 기판에 금속 배선 형성 (Metallization on Patterned Substrate)

  • 김남석;강탁;남승우;박용수
    • 한국표면공학회지
    • /
    • 제28권5호
    • /
    • pp.309-319
    • /
    • 1995
  • The substrate patterned with the dry film has the cavity which has the $90^{\circ}$ wall angle. Electroplating Cu on this patterned substrate has the differrent shape history with the electrochemical parameters. By potential theory model, the reason of the variation of the shape change with the these parameters was investigated. The shape history could be explained by the current flow and the correlated area effects. By embedding the Ni layer between the Cu layers, shape history with the time was obtained experimentally and the results was compared with the numerical analysis by BEM. The adhesive Cr-Cu film in TAB application was etched with the various condition. The best condition for the etchant of the Cr-Cu film was found.

  • PDF