• Title/Summary/Keyword: Ni variation

Search Result 407, Processing Time 0.022 seconds

A Study About Radionuclides Migration Behavior in Terms of Solubility at Gyeongju Low- and Intermediate-Level Radioactive Waste (LILW) Repository

  • Park, Sang June;Byon, Jihyang;Lee, Jun-Yeop;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.113-121
    • /
    • 2021
  • A safety assessment of radioactive waste repositories is a mandatory requirement process because there are possible radiological hazards owing to radionuclide migration from radioactive waste to the biosphere. For a reliable safety assessment, it is important to establish a parameter database that reflects the site-specific characteristics of the disposal facility and repository site. From this perspective, solubility, a major geochemical parameter, has been chosen as an important parameter for modeling the migration behavior of radionuclides. The solubilities were derived for Am, Ni, Tc, and U, which were major radionuclides in this study, and on-site groundwater data reflecting the operational conditions of the Gyeongju low and intermediate level radioactive waste (LILW) repository were applied to reflect the site-specific characteristics. The radiation dose was derived by applying the solubility and radionuclide inventory data to the RESRAD-OFFSITE code, and sensitivity analysis of the dose according to the solubility variation was performed. As a result, owing to the low amount of radionuclide inventory, the dose variation was insignificant. The derived solubility can be used as the main input data for the safety assessment of the Gyeongju LILW repository in the future.

Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube (증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발)

  • Park, Duck-Gun;Ryu, Kwon-Sang;Lee, Jeong-Kee;Son, De-Rac
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2008
  • A new ECT probe to separate the ECT signal distortion due to PVC (permeability variation clusters) and ordinary defects created in SG tubes has been developed. The hystersis loops of PVC which are extracted from retired SG (steam generator) tubes of Kori-1 NNP were measured. The tensile tests were performed to identify the mechanism of PVC creation. The conditions detecting the PVC created in 56 tubes were investigated using computer simulation, and the signal processing circuits were inserted in the probe for the digital signal transmission. The new Probe can measure and separate the PVC signal which is created in the SG tubes, and also measures the defects in Ni-sleeving part of SG tubes. furthermore the new ECT probe can measure the defects as fast as bobbin probe, and enhance the testing speed as well as reliability of the defect detection of SG tubes.

Pathologic Response During Chemo-radiotherapy and Variation of Serum VEGF Levels Could Predict Effects of Chemo-Radiotherapy in Patients with Esophageal Cancer

  • Yu, Jing-Ping;Lu, Wen-Bin;Wang, Jian-Lin;Ni, Xin-Chu;Wang, Jian;Sun, Zhi-Qiang;Sun, Su-Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1111-1116
    • /
    • 2015
  • Background: To investigate the relationship between pathologic tumor response to concurrent chemoradiotherapy and variation of serum VEGF in patients with esophageal cancer. Materials and Methods: Forty six patients with esophageal cancer who were treated with concurrent chemo-radiotherapy were enrolled. Endoscopic and pathologic examination was conducted before and four weeks afterwards. Serum level of VEGF was documented before, four weeks later and after chemo-radiotherapy. The relationship between pathologic response and the variation of serum level of VEGF and its influence on the prognosis were investigated. Results: Serum level of VEGF decreased remarkably during and after chemo-radiotherapy in patients whose pathologic response was severe (F=5.393, 4.587, P(0.05). There were no statistical differences of serum VEGF level before, during and after chemo-radiotherapy for patients whose pathologic response was moderate or mild. There were 18 (85.7%), 7 (53.8%) and 6 patients (50.0%) whose serum VEGF level dropped in the severe, moderate and mild group, respectively, with significant differences among these groups (p=0.046). Two year survival rates of patients with severe, moderate and mild pathologic response were 61.9%, 53.8% and 33.3% respectively, and no statistically difference between severe and mild group regarding OS (p=0.245) was tested. Conclusions: Tumor pathologic response during chemo-radiotherapy and the changes of serum VEGF lever could predict curative effects of chemo-radiotherapy in patients with esophageal cancer.

Distribution Characteristics of PM10 and Heavy Metals in Ambient Air of Gyeonggi-do Area using Statistical Analysis (통계분석을 이용한 경기도 대기 중 미세먼지 및 중금속 분포 특성)

  • Kim, Jong Soo;Hong, Soon Mo;Kim, Myoung Sook;Kim, Yo Yong;Shin, Eun Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.281-290
    • /
    • 2014
  • This study was conducted to evaluate the distribution characteristics of $PM_{10}$ and heavy metals concentrations in the ambient air of Gyeonggi-do area by region and season from February, 2013 to March, 2014. The regression model for the prediction of formation characteristics and contamination degree of $PM_{10}$ and heavy metals by correlation analysis and regression analysis for using the multivariate statistical analysis was also established. The main wind direction during the investigation period was South East (SE) and West South West (WSW) winds, and the concentration of $SO_2$ at Ansan with industrial region showed 1.6 times higher than Suwon, Euiwang with residential region. The concentrations (median) of Pb, Cu and Ni at Ansan showed 3.2~4.5, 1.9~2.2 and 1.7~2.6 times respectively higher than those at Suwon. By the seasonal concentration variation, the concentrations of $PM_{10}$, Pb, Fe and As in winter and spring (December to May) showed 1.7, 1.9, 1.9 and 2.7 times respectively higher than those in summer and fall (June to November). As, Fe and $PM_{10}$ had a big difference by the seasonal factors, and Cu and Ni were evaluated to be influenced by the regional factors. From the results of correlation analysis among the target items, the correlation coefficient of PM and Mn had 0.82 (p/0.01) and that of Fe and Mn had 0.82 (p/0.01), which showed high correlation. And the correlation coefficients for $SO_2$ and Pb, CO and $PM_{10}$ were 0.66 (p/0.01) and 0.62 (p/0.01) respectively. The multiple linear regression models for $PM_{10}$, Pb, Cu, Cr, As, Ni, Fe and Mn were established by independent variables of CO, $SO_2$ and meteorological factors (wind speed, relative humidity). In the regression models, independent variable $SO_2$ was in cause-and-effect relationship with all dependent variables, and $PM_{10}$, Fe and Mn were influenced by CO and wind speed, and Pb, Cu, Ni and As had a main factor of $SO_2$.

Heavy Metal Contents in Wild and Cultured Fishes from the Korean Coasts (국내 시중 유통 자연산 및 양식산 활어의 중금속 함량)

  • Mok, Jong-Soo;Shim, Kil-Bo;Lee, Tae-Seek;Song, Ki-Cheol;Lee, Ka-Jeong;Kim, Seong-Gil;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.6
    • /
    • pp.561-568
    • /
    • 2009
  • We determined the contents of heavy metals in the muscle of wild and cultured fishes, collected from fish markets located in the eastern (Pohang), western (Gunsan), and southern (Tongyeong) coasts of Korea, from 2004 to 2005. As the results of monitoring the heavy metal contents in spring season, the wild fishes contained the range of Cd (0.01-0.08 mg/kg), Cr (ND-0.28 mg/kg), Cu (0.06-1.53 mg/kg), Hg (0.02-0.16 mg/kg), Mn (0.04-1.15 mg/kg), Ni (ND-0.09 mg/kg), Pb (0.03-0.41 mg/kg), and Zn (1.84-6.61 mg/kg). While for the cultured fishes, Cd (0.01-0.05 mg/kg), Cr (ND-0.17 mg/kg), Cu (0.05-0.61 mg/kg), Hg (0.02-0.13 mg/kg), Mn (0.03-0.17 mg/kg), Ni (ND-0.08 mg/kg), Pb (0.03-0.33 mg/kg), and Zn (2.06-6.20 mg/kg) were contained. In summer season, the contents of heavy metal in the muscle of the wild fishes were as follows: Cd (ND-0.11 mg/kg), Cr (0.01-0.37 mg/kg), Cu (0.21-1.31 mg/kg), Hg (0.01-0.11 mg/kg), Mn (ND-1.47 mg/kg), Ni (ND-0.26 mg/kg), Pb (0.06-0.48 mg/kg), and Zn (2.94-14.38 mg/kg). In comparison, the contents of heavy metal in the muscle of cultured fishes were Cd (ND-0.05 mg/kg), Cr (0.13-0.33 mg/kg), Cu (0.19-0.56 mg/kg), Hg (0.05-0.26 mg/kg), Mn (ND-0.14 mg/kg), Ni (ND-0.58 mg/kg), Pb (0.07-0.45 mg/kg), and Zn (2.43-7.53 mg/kg). Also the fall and the winter season, the heavy metal contents in the fishes showed almost similar with other season, however, Pb was lower and Zn was higher than both spring and summer season. The wild fishes contained the heavy metals a little more than the cultured fishes. We could not observe clear seasonal variation in the heavy metal contents of the fishes. The levels of Hg and Pb in all samples tested did not exceed the maximum permissible levels in the fishes set by the Korean Food & Drug Agency for safe human consumption.

Detection Characteristics of a Red Blood Cell Coupled with Micron Magnetic Beads by Using GMR-SV Device (GMR-SV 소자를 이용한 미크론 자성비드와 결합된 적혈구 검출 특성 연구)

  • Lee, Jae-Yeon;Kim, Moon-Jong;Lee, Sang-Suk;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.101-106
    • /
    • 2014
  • The glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(2.3 nm)/NiFe(3 nm)/IrMn(12 nm)/Ta(5.8 nm) GMR-SV (giantmagneto-resistance-spin valve) multilayer structure films with a magnetoresistance ratio (MR) of 5.0 % and a magnetic sensitivity (MS) of 1.5%/Oe was deposited by dc magnetron sputtering method. Also, GMR-SV device having a width of $7{\mu}m{\sim}8{\mu}m$ similar to the diameter of RBC (red blood cell) was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ dropped upon the GMR-SV device having MR = 1.06% and MS = 0.3 %/Oe, there is observed the variation of about included of a resistance value of ${\Delta}R=0.4{\Omega}$ and ${\Delta}MR=0.15%$ around a external magnetic field of -0.6 Oe. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property of hemoglobin inside of RBC combined to magnetic beads.

Heavy Metal Concentrations in the Mollusc Gastropod, Cipangopaludina chinensis malleata from Upo Wetland Reflect the Level of Heavy Metals in the Sediments

  • Kim, Heung-Tae;Kim, Jae-Geun
    • Journal of Ecology and Environment
    • /
    • v.29 no.5
    • /
    • pp.453-460
    • /
    • 2006
  • Upo wetland is the largest inland wetland in Korea as Ramsar Convention Area. The purposes of the study were to investigate the levels of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn) in the sediment and Cipangopaludina chinensis malleata from three sites of the wetland and to assess the potential of the gastropod as a bioindicator for heavy metal levels. The gastropods were dissected into shell and soft tissue without the digestive and excretive organs. The levels of Cd, Cu and Pb were below the guideline of Soil Environment Conservation Act and the heavy metals except Cr were slightly different among the sites. Cd was higher in Upo site ($0.32{\mu}g/g$) than Sajipo site ($0.28{\mu}g/g$). Cu and Zn showed the highest value in Sajipo as $43.5{\mu}g/g\;and\;39.8{\mu}g/g$, respectively while the concentrations of Pb and Zn were the highest in Upstream as $58.8{\mu}g/g\;and\;138{\mu}g/g$, respectively. In the soft tissues and shells of the gastropod, the overall common trend in the concentrations of the heavy metals was revealed with the following order: Zn > Cu > Cr > Ni > Pb > Cd and Ni > Zn > Cr > Cu > Pb > Cd, respectively. Although the soft tissues exhibited higher concentrations of the heavy metals except Ni than the shell in the gastropod, the levels of Cd and Pb in the gastropod were generally below the restrictive values set up by Korea Food & Drug Administration. From Duncan's Multiple Range Test (DMRT) results, the concentrations of Pb and Zn in the sediments among the sites were reflected on the soft tissue (Pb) and the shell (Pb and Zn) of the gastropod in the same order. The lower value of coefficient of variation (CV) in Pb concentration of the shell than in that of the soft tissue supports the usefulness of the shell as a bioindicator for Pb pollution. Although the CV value in the shell was a little higher than in the soft tissue, DMRT results and the stability of incorporated Zn into the shell support the use of the shell of the gastropod as a potential bioindicator for long-term contamination of Zn.

Structural and Electrical Properties of [(Co1-xCux)0.2(Ni0.3Mn0.7)0.8]3O4 Spinel Thin Films for Infrared Sensor Application (적외선 센서용 [(Co1-xCux)0.2(Ni0.3Mn0.7)0.8]3O4 스피넬 박막의 구조 및 전기적 특성)

  • Lee, Kui Woong;Jeon, Chang Jun;Jeong, Young Hun;Yun, Ji Sun;Cho, Jeong Ho;Paik, Jong Hoo;Yoon, Jong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.12
    • /
    • pp.825-830
    • /
    • 2014
  • $[(Co_{1-x}Cu_x)_{0.2}(Ni_{0.3}Mn_{0.7})_{0.8}]_3O_4$ ($0{\leq}x{\leq}1$) thin films prepared by metal organic decomposition process were fabricated on SiN/Si substrate for infrared sensor application. Their structural and electrical properties were investigated with variation of Cu dopant. The $[(Co_{1-x}Cu_x)_{0.2}(Ni_{0.3}Mn_{0.7})_{0.8}]_3O_4$ (CCNMO) film annealed at $500^{\circ}C$ exhibited a dense microstructure and a homogeneous crystal structure with a cubic spinel phase. Their crystallinity was further enhanced with increasing doped Cu amount. The 120 nm-thick CCNMO (x=0.6) thin film had a low resistivity of $53{\Omega}{\cdot}cm$ at room temperature while the Co-free film (x=1) showed a significantly decreased resistivity of $5.9{\Omega}{\cdot}cm$. Furthermore, the negative temperature coefficient of resistance (NTCR) characteristics were lower than $-2%/^{\circ}C$ for all the specimens with $x{\geq}0.6$. These results imply that the CCNMO ($x{\geq}0.6$) thin films are a good candidate material for infrared sensor application.

Electric Properties of Step-up Piezoelectric transformer by dimension variation

  • Joo, Hyeon-Kyu;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung;Vo, Vietthang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.103-103
    • /
    • 2009
  • In this study, in order to develop high power piezoelectric transformer, we compared the piezoelectric transformers dimension. The basic composition of piezoelectric ceramics is ternary $0.01Pb(Ni_{1/3}Nb_{2/3})O_3-0.08Pb(Mn_{1/3}Nb_{2/3})O_3-0.91Pb(Zr_{0.505}Ti_{0.495})O_3$. The voltage step up ratio of piezoelectric transformer showed the maximum value at the near of 81 kHz and increased according to the increase of load resistance.

  • PDF

Metallization on Patterned Substrate (패턴된 기판에 금속 배선 형성)

  • 김남석;강탁;남승우;박용수
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.5
    • /
    • pp.309-319
    • /
    • 1995
  • The substrate patterned with the dry film has the cavity which has the $90^{\circ}$ wall angle. Electroplating Cu on this patterned substrate has the differrent shape history with the electrochemical parameters. By potential theory model, the reason of the variation of the shape change with the these parameters was investigated. The shape history could be explained by the current flow and the correlated area effects. By embedding the Ni layer between the Cu layers, shape history with the time was obtained experimentally and the results was compared with the numerical analysis by BEM. The adhesive Cr-Cu film in TAB application was etched with the various condition. The best condition for the etchant of the Cr-Cu film was found.

  • PDF