• Title/Summary/Keyword: Next generation technology

Search Result 2,098, Processing Time 0.036 seconds

Parametric Evaluation Method of Protectability in a Distribution System (파라메터 관점에서의 배전계통 보호도 평가방법)

  • Cho, P.S.;Hyun, S.H.;Lim, S.I.;Lee, S.J.;Lee, D.S.;Waldemar, Waldemar
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.241-243
    • /
    • 2002
  • Recently, great efforts are concentrated on the autonomous, adaptive protection schemes with advanced artificial intelligence and digital technology. It is highly required for a next generation protective system not only to detect and to clear a fault, but also to fit itself to the changing environment. In this paper it is suggested an evaluation method for the protection ability of a protective system in a distributed system. The suggested method is of bottom-up scheme, in other words, protection ability is estimated from the lowest level of parameters in each protective devices to the highest level of the whole protective system. This feature makes it possible to evaluate the protection ability either for the protective device(or a system), or for a protected system. And, in addition, it is enabled that the protectability concept can be applied in the design stage of a protective system for a distribution network. The proposed method is applied to a simple distributed network to show its effectiveness.

  • PDF

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.

Giga WDM-PON based on ASE Injection R-SOA (ASE 주입형 R-SOA 기반 기가급 WDM-PON 연구)

  • Shin Hong-Seok;Hyun Yoo-Jeong;Lee Kyung-Woo;Park Sung-Bum;Shin Dong-Jae;Jung Dae-Kwang;Kim Seung-Woo;Yun In-Kuk;Lee Jeong-Seok;Oh Yun-Je;Park Jin-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.35-44
    • /
    • 2006
  • Reflective semiconductor optical amplifiers(R-SOAs) were designed with high gain, wide optical bandwidth, high thermal reliability and wide modulation bandwidth in TO-can package for the transmitter of wavelength division multiplexed-passive optical network(WDM-PON) application. Double trench structure and current block layer were introduced in designing the active layer of R-SOA to enable high speed modulation. The injection power requirement and the viable temperature range of WDM-PON system are experimentally analysed in based on Amplified Spontaneous Emission(ASE)-injected R-SOAs. The effect of the different injection spectrum in the gain-saturated R-SOA was experimentally characterized based on the measurements of excessive intensity noise, Q factor, and BER. The proposed spectral pre-composition method reduces the bandwidth of injection source below the AWG bandwidth and thereby avoids spectrum distortion impeding the intensity noise reduction originated from the amplitude squeezing.

Design Framework for Next Generation Mobile Convergence Service Models (차세대 이동통신 컨버전스 서비스 모델 개발 프레임워크)

  • Shin, Dong-Chun;Kim, Jin-Bae;Park, Sei-Kwon;Ryu, Seung-Wan
    • Journal of Information Technology Services
    • /
    • v.9 no.4
    • /
    • pp.243-259
    • /
    • 2010
  • It is expected that the next generation mobile communication system will be a service-driven developed system capable to realize the human-centric mobile convergence services. and it is different from the technology-driven development approach of the second and the third generation mobile communication systems. As a preliminary research work on such service-driven system development approach for the next generation mobile communication system. we developed the scenario based service analysis process (2SAP) framework to derive core service technologies and functionalities. In this paper. we propose the next generation mobile convergence service business model creation methodology based on research results of the 2SAP framework. To achieve this goal, we first establish a service model contains several components such as infrastructures. operations. and provision of services that are indispensible for providing next generation mobile services. Then, the next generation mobile services and its corresponding business models can be created by adding service and value flows to the developed service model after defining necessary components of business model including actors, their relationships, and roles.

A Study of Power Quality Monitoring System Using Web Technology (웹 기술을 이용한 전기품질 감시시스템 연구)

  • Lee, K.S.;Lim, S.I.;Lee, S.J.;Lee, D.W.;Park, D.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.148-150
    • /
    • 2003
  • A meaning of power quality has changed, which affects on an environmental change of existing electricity supply markets. Today, it should take both consumers and suppliers into consideration to develop information and communication technology and to increase the use of power and electronic equipments. As a result, it is necessary to develop a system to monitor power quality and to display data. In this paper, a system, as a power quality monitoring equipment, which can use protective replays with progress of microprocessor technology and provide information in the intranet/internet circumstances using web-based architecture is described.

  • PDF

Fault Section Detection Scheme in Ungrounded Distribution System (비접지 배전계통에서 고장구간 검출 및 복구 알고리즘)

  • Yu, Fei;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.487-488
    • /
    • 2007
  • Fault section detection and service restoration is very important in ungrounded distribution system. Techniques currently used to track down faults are time consuming and cumbersome. A new scheme is developed based on communication technology, and the simulation result shows that the method can satisfy the requirement proposed.

  • PDF

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

Experiment and Electro-Thermo-Chemical Modeling on Rapid Resistive Discharge of Large-Capacity Lithium Ion Battery

  • Doh, Chil-Hoon;Ha, Yoon-Cheol;Eom, Seung-Wook;Yu, Jihyun;Choe, Seon-Hwa;Kim, Seog-Whan;Choi, Jae-Won
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.323-338
    • /
    • 2022
  • Heat generation and temperature of a battery is usually presented by an equation of current. This means that we need to adopt time domain calculation to obtain thermal characteristics of the battery. To avoid the complicated calculations using time domain, 'state of charge (SOC)' can be used as an independent variable. A SOC based calculation method is elucidated through the comparison between the calculated results and experimental results together. Experiments are carried for rapid resistive discharge of a large-capacitive lithium secondary battery to evaluate variations of cell potential, current and temperature. Calculations are performed based on open-circuit cell potential (SOC,T), internal resistance (SOC,T) and entropy (SOC) with specific heat capacity.

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF