• 제목/요약/키워드: Next generation

검색결과 5,372건 처리시간 0.046초

DNP3.0을 이용한 과전류 계전기 에이전트의 통신 방안 연구 (A Study on communication method between OverCurrent Relay Agents using DNP 3.0)

  • 이한웅;정광호;임성일;현승호;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.265-267
    • /
    • 2002
  • In this paper, the communication between Over-Current Relay agents is realized using DNP(Distributed Network Protocol), which is the standard communication protocol of distribution automation system in KEPKO. The key words in OCR agent communication are defined and represented by use of DNP application function code. And the DNP index for OCR agent is defined. The proposed communication scheme is tested by use of Communication Test Harness, a test tool for DNP protocol to show its soundness.

  • PDF

파라미터를 이용한 배전계통 보호능력 평가 및 최적화 (Optimal protection by using Parametric Protection Ability Index)

  • 신재항;현승호;임성일;이승재;최인선;진보건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.202-204
    • /
    • 2003
  • This paper suggests an optimal parameter setting method by use of parametric protectability index, as the objective function. In this paper, a gradient based optimization method is used under the assumption that the initial values of a parameter is in a convex set including the optimal value, which is verified by a plenty of simulation studies. The proposed method is applied to a sample distribution network to shows its effectiveness.

  • PDF

넥스트 제너레이션 게임애니메이션 연구 (Study of Next Generation Game Animation)

  • 박홍규
    • 만화애니메이션 연구
    • /
    • 통권13호
    • /
    • pp.223-236
    • /
    • 2008
  • 본 논문에서는 강력한 하드웨어 게임콘솔을 타깃으로 제작되는 넥스트 제너레이션 게임의 탄생배경과 의미, 그 새로운 개념의 등장으로 인해 현 게임인더스트리에 요구되어지는 제작구조의 변화를 슈터게임을 중심으로 분석했으며, 이 전의 슈터게임 애니메이션 파이프라인과 구별되는 넥스트 제너레이션 게임 애니메이션의 필요성과 그 제작과정을 정리하였다. 더불어 최근 북미 게임 인더스트리에서 시도되고 있는 기술적 도전들을 살펴봄으로써 넥스트 제너레이션 게임의 새로운 가능성과 과제들을 연구하는 것이 본 논문에 목적이다.

  • PDF

전기자동차용 전지관리 시스템의 개발 (Development of Battery Management System for Electric Vehicle)

  • 김진곤;성기택;김석형;구재승;박선순;윤길영;김철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1223-1225
    • /
    • 2002
  • This paper has described in Electric Vehicle Battery Management System(EV BMS). EV BMS manages the input/output energy of the traction battery, and provides the optimum environment condition during charging/ driving through the communication with other controllers. In this paper, we introduce our BMS for Santa Fe EV. Hyundai Motor Company has been developed EV since 1990. Recently, Santa Fe EV has been demonstrating with the environmental friendly technology. Two year real road testing program with electric powered Santa Fe is being undertaken by HMC in Hawaii.

  • PDF

자율적응형 과전류계전기 에이전트의 통신을 위한 ACL모듈 개발 (Development of ACL Modul For Agent Communication in Auto-Adaptive OCR Agent)

  • 오태욱;이승재;최면송;김기화;임성일;민병운;이한웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 2002
  • In this paper, a communication module is proposed to be applied to communication between over current relay (OCR) agents in multi agent protection system. A multi agent system can achieve a global goal beyond the ability of each individual agent by working together, in which it is the prerequisite for each agent to be able to exchange or share information or processing status with other agent. The proposed communication module is purposed to enable not only each agent to bring about its own goal, but also the whole protective system to provide much improved coordinated protection. It is applied to a self adaptive protection system for a distribution network using multi agent concept to show its effectiveness.

  • PDF

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.