• 제목/요약/키워드: Newly apartment houses

검색결과 31건 처리시간 0.021초

입주전 신축공동주택의 봄철 TVOC, HCHO농도 실태조사에 관한 연구 (A study on the field measurement of the TVOC and HCHO concentration in the newly constructed apartment houses in spring seasons)

  • 최승혁;김건우;이종식;박진철;김신도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.126-131
    • /
    • 2007
  • This study aims to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as HCHO and VOCs and the field measurement were conducted. According to the field measurement of 60 new houses in spring season, the concentration of HCHO in about 20% were higher the IAQ standards.

  • PDF

공동주택 분양가 결정모형에 관한 연구 (A Study of the Decision to Standardize Sale Price Model of Supplying Apartment Houses)

  • 황규성;이찬호
    • 디지털융복합연구
    • /
    • 제15권1호
    • /
    • pp.181-189
    • /
    • 2017
  • 본 연구는 아파트 신규 공급 시 시장 내 경쟁력 있는 분양가격을 결정하기 위한 산정기준을 마련하였다. 도출된 모형은 건설사가 새로운 아파트 분양 시 가격결정을 토지비와 공사비 등 들어가는 비용에 일정 이윤을 합하는 방식이 아니고 최근 공급한 새로운 아파트 단지의 가격을 기준으로 결정하는 방법으로 이루어지고 있음을 고려하여 인근 아파트와 분양가격 비교분석의 모형을 만들었다. 아파트를 새로 공급할 때 결정요인에 대하여 1단계 4가지요인, 2단계 9가지요인, 3단계 25가지 요인으로 계층화하여 분석함으로써 새로이 공급되는 아파트의 가격을 산정하기 위한 기준을 마련하고자 한다. 분양가격 결정요인의 상대적 중요도도 파악하여서 신규공급 아파트 분양가격의 분양시 지표로 활용한다. 또한 2단계 9가지 요인특성을 기준으로 분양가 비교 모형을 만들어 실무에 적용할 수 있도록 제시하였다. 향후에는 마케팅 외적인 요인도 추가적으로 고려하여 일반화된 기준을 찾는 연구가 필요 할 것이다.

아파트 개조 전후의 휘발성유기화합물 농도변화 실태 (The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses)

  • 최윤정;심현숙;신해철
    • 한국주거학회논문집
    • /
    • 제18권4호
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

AHP기법을 이용한 공동주택 분양가 결정에 관한연구 (A study of the decision to standardize sale price of supplying apartment houses using Analytic Hierarchy Process)

  • 황규성;이찬호
    • 디지털융복합연구
    • /
    • 제14권1호
    • /
    • pp.121-129
    • /
    • 2016
  • 본 연구의 목적은 아파트 분양가격의 결정요인에 대하여 AHP 분석방법으로 신규공급 아파트의 가격 산정을 위한 기준을 마련하고자 한다. 아파트 분양가격의 분양가격 결정요인을 계층구조로 모델링한다. 모델링한 계층구조에 따라서 부동산전문가그룹의 설문으로 분양요소들의 상대적 중요도를 파악한다. 그리고 AHP 분석방법으로 단계별 분양가격 결정요인의 상대적 중요도 찾아내어서 신규공급 아파트의 경쟁력 있는 분양가격 산정을 위한 기준을 마련하고자 한다.

아파트 리모델링 전.후의 휘발성유기화합물 농도 변화 (The Concentration Ascension of Volatile Organic Compounds after Remodeling in Apartment Houses)

  • 최윤정;신해철;심현숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.287-290
    • /
    • 2006
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after remodeling in apartment houses and to analyze the relation of concentrated ascension and remodeling elements. The field measurements of TVOC and HCHO concentration were carried out in 4 subject apartment houses according to the Korea Test Method Standard for Indoor Air Quality. The results are as follows; the TVOC concentration after remodeling ranged from mean 0.35ppm to mean 5.08ppm and increased of 0.35$^{\sim}$5.08ppm. The concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.7ppm). The HCHO concentration after remodeling ranged from mean 0.13ppm to mean 0.43ppm and increased of 0.06$^{\sim}$0.26ppm. The concentration of 2 subjects exceeded the Standard (0.16ppm). As results of analysis on the relation of concentrated ascension and remodeling elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

  • PDF

대형 공동주택 거실 조명환경과 행위별 조명사용에 관한 조사연구 (Investigations on Lighting Environment of Living Room and Lighting Use According to the Behavior in Large Apartment Houses)

  • 김현지;김훈
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.1-8
    • /
    • 2012
  • This study investigated current status of lighting environment, residents' awareness of lighting and lighting use according to behavior in the living room of apartment to determine current lighting trends and their related problems. The living rooms of newly-built apartment units(133~165[$m^2$] and larger than 166[$m^2$] within the past five years) were examined. The results are summarized as follows. 1. Resident satisfaction with current living room lighting was the highest in 'illumination' and the lowest was 'energy savings' regardless of the size of living room. 2. This kind of ceiling lighting layout, 133~165[$m^2$] unit used central lighting and larger than 166[$m^2$] units used central lighting and cove lighting. Regarding light sources, 133~165[$m^2$] linear FL, halogen, larger than 166[$m^2$] bulb-type FL are widely used. LED are now being found in the living room corridor and kitchen walls of newly-built apartment houses. 3. Watching TV and reading books were commonly behaved in the living room. Conversations between family, having desserts, resting, housekeeping, and entertaining were usually done weekdays, while having desserts and conversations between family were done weekends. Use of lighting as main behaviors is properly and differently required due to the distinct uses of lighting as residents' behaviors or their life style.

신축목조주택의 실내공기질 특성 및 관련요인 분석 (Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses)

  • 최윤정;이재경;차예랑
    • 한국주거학회논문집
    • /
    • 제26권4호
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응 (TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments)

  • 최윤정;안혜정;강미라;이혜민
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

공동주택의 실내공기환경 개선에 관한 연구 (A Study on the Improvement of Indoor Air Quality in Apartment Buildings)

  • 이상형;박진철;이언구
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF

공동주택 단위난방부하 계산을 위한 단위동법 제안 (Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses)

  • 유호선;정주혁;문정환;이재헌
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.