• Title/Summary/Keyword: Neutron Screen

Search Result 8, Processing Time 0.02 seconds

DESIGN OF A NEUTRON SCREEN FOR 6-INCH NEUTRON TRANSMUTATION DOPING IN HANARO

  • Kim, Hak-Sung;Oh, Soo-Youl;Jun, Byung-Jin;Kim, Myong-Seop;Seo, Chul-Gyo;Kim, Heon-Il
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.675-680
    • /
    • 2006
  • The neutron transmutation doping of silicon (NTD), as a method to produce a high quality semiconductor, utilizes the transmutation of a silicon element into phosphorus by neutron absorption in a silicon single crystal. In this paper, we present the design of a neutron screen for a 6' Si ingot irradiation in the NTD2 hole of HANARO. The goal of the design is to achieve an even flat axial distribution of the resistivity, or $Si^{30}(n,{\gamma})Si^{31}$ reaction rate, in the irradiated Si ingot. We used the MCNP4C code to simulate the neutron screen and to calculate the reaction rate distribution in the Si ingot. The fluctuations in the axial distribution were estimated to be within ${\pm}2.0%$ from the average for the final neutron screen design; thus, they satisfy the customers' requirement for uniform irradiation. On the other hand, we determined the optimal insertion depths of the Si ingots by varying the critical control rod position, which greatly affects the axial flux distribution.

GYAGG/6LiF composite scintillation screen for neutron detection

  • Fedorov, A.;Komendo, I.;Amelina, A.;Gordienko, E.;Gurinovich, V.;Guzov, V.;Dosovitskiy, G.;Kozhemyakin, V.;Kozlov, D.;Lopatik, A.;Mechinsky, V.;Retivov, V.;Smyslova, V.;Zharova, A.;Korzhik, M.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1024-1029
    • /
    • 2022
  • Composite scintillation screens on a base of Gd1.2Y1.8Ga2.5Al2.5O12:Ce (GYAGG) scintillator have been evaluated for neutron detection. Besides the powdered scintillator, the composite includes 6LiF particles; both are merged with a binder and deposited onto the light-reflecting aluminum substrate. Results obtained demonstrates that screens are suitable for use with a silicon photomultiplier readout to create a prospective solution for a compact and low-cost thermal neutron sensor. Composite GYAGG/6LiF scintillation screen shows a pretty matched sensitivity and γ-background rejection with a widely used ZnS/6LiF screens however, possesses forty times faster response.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

RADIAL UNIFORMITY OF NEUTRON IRRADIATION IN SILICON INGOTS FOR NEUTRON TRANSMUTATION DOPING AT HANARO

  • KIM MYONG-SEOP;LEE CHOONG-SUNG;OH SOO-YOUL;HWANG SUNG-YUL;JUN BYUNG-JIN
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.93-98
    • /
    • 2006
  • The radial uniformity of neutron irradiation in silicon ingots for neutron transmutation doping (NTD) at HANARO is examined by both calculations and measurements. HANARO has two NTD holes named NTD1 and NTD2. We have been using the NTD2 hole for 5 in. NTD commercial service, and we intend to use two holes for 6 in. NTD. The objective of this study is to predict the radial uniformity of 6 in. NTD at the two holes. The radial neutron flux distributions inside single crystal and noncrystal silicon loaded at the NTD2 hole are calculated by the VENTURE code. For NTD1, the radial distributions of the reaction rate for a 6 in. NTD with a neutron screen are calculated by MCNP, and measured by gold wire activation. The results of the measurements are compared with those of the calculations. From the VENTURE calculation, it is confirmed that the neutron flux distribution in the single crystal silicon is much flatter than that in the non-crystal silicon. The non-uniformities of the measurements for radial neutron irradiation are slightly larger than those of the calculations. However, excluding local dips in the measurements, the overall trends of the distributions are similar. The radial resistivity gradient (RRG) for a 5 in. silicon ingot is estimated to be about $1.5\%$. For a 6 in. ingot, the RRG of a silicon ingot irradiated at HANARO is predicted to be about $2.1\%$. Also, from the experimental results, we expect that the RRG would not be larger than $4.4\%$.

A Study On Hardware Design for High Speed High Precision Neutron Measurement (고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • In this paper, a hardware design method is proposed for high speed high precision neutron radiation measurements. Our system is fabricated to use a high performance A/D Converter for digital data conversion of high precision and high speed analog signals. Using a neutron sensor, incident neutron radiation particles are detected; a precision microcurrent measurement module is also included: this module allows for more precise and rapid neutron radiation measurement design. The high speed high precision neutron measurement hardware system is composed of the neutron sensor, variable high voltage generator, microcurrent precision measurement component, embedded system, and display screen. The neutron sensor detects neutron radiation using high density polyethylene. The variable high voltage generator functions as a 0 ~ 2KV variable high voltage generator that is robust against heat and noise; this generator allows the neutron sensor to perform normally. The microcurrent precision measurement component employs a high performance A/D Converter to precisely and swiftly measure the high precision high speed microcurrent signal from the neutron sensor and to convert this analog signal into a digital one. The embedded system component performs multiple functions including neutron radiation measurement for high speed high precision neutron measurements, variable high voltage generator control, wired and wireless communications control, and data recording. Experiments using the proposed high speed high precision neutron measurement hardware shows that the hardware exhibits superior performance compared to that of conventional equipment with regard to measurement uncertainty, neutron measurement rate, accuracy, and neutron measurement range.

Analysis of Radioactive Characterization in the Medical Linear Accelerator Shielding Wall Using Monte Carlo Method (몬테칼로법을 이용한 의료용 선형가속기 차폐벽의 방사화 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.758-765
    • /
    • 2016
  • This study analyzed for the radioactive shielding wall, which shields the medical linear accelerator. This allows to evaluate the level of waste with respect to the shield wall, which accounts for more than half of the cost of dismantling later linac facility. In addition, by analyzing the waste processing method according we discuss the way to obtain the benefits in terms of dismantling cost. Results of the simulate, the amount sufficient to screen the amount of neutron radiation occurring in the shielding wall linac was measured. And neutron activation analysis results were analyzed nuclides more than about 20. This analysis was in excess of that, $^{24}Na$, $^{45}Ca$, $^{59}Fe$ nucleus paper deregulation concentration. The value is reduced is greater the deeper the depth of the shielding wall concentration. Based on this, three specific areas (E, F, G) was estimated to be impossible to landfill or recycling. The rest area was estimated to be buried or recycled if possible more than a predetermined depth.