• Title/Summary/Keyword: Neutralizer

Search Result 53, Processing Time 0.024 seconds

Field Control Type Electrostatic Charge Neutralizer (전계 제어형 정전하 중화장치)

  • Jeong, Seok-Hwan;Lee, Dae-Hui;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.469-474
    • /
    • 1999
  • Methods and systems to remove static electricity are requested in the field of industry because the static electricity causes a flammable gas explosion or fire and a reduction of production rate in manufacturing semiconductor devices and so on. This paper is a basic study about a new structure of electrode system to control the quantities of generated ions and to solve the problem of dust attachment to needle electrode. In addition, a new type field controlled electrostatic charge neutralizer was proposed, and it could control the electric field in the end of the needle electrode by controlling the voltage of the third electrode around the tip of the needle electrode. As aresult, it was possible to control the quantities of generated ion by controlling the electric field in the needle electrode with the third electrode, which shows the possibilities to solve the nonequilibrium of generated ions in ac power source and the problem of the dust in the needle electrode.

  • PDF

Degradation and Neutralization of Total Residual Oxidant (TRO) in the Treated Ballast Water by Ozonation

  • Park, Sung-Jin;Bin, Jung-In;Lee, Eon-Sung;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.399-406
    • /
    • 2010
  • The aims of this study are to provide data on the ozone dosage control system and TRO sensor performance, to assess the performance of the degradation of total residual oxidant (TRO) neutralizer and to provide data on degradation rates of TRO in the ballast tanks, following treatment by the Ozone BWTS. This study includes the results of an evaluation of the TRO neutralizer, which was tested on the test barge. Accordingly, it has undertaken the evaluation of TRO degradation rates following treatment by the Ozone BWTS.

Development and Evaluation of Hy-SMPS (Hy-SMPS의 개발 및 성능평가)

  • Lee, Hong-Ku;Eun, Hee-Ram;Lee, Gun-Ho;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.57-61
    • /
    • 2015
  • Atmospheric nano-particles along the altitude is one of the main factors causing severe weather phenomena. It is a challenge to find the precise particle size distribution. One useful instrument includes a scanning mobility particle sizer (SMPS). This measures the size distribution of submicron aerosols. The SMPS consists of a condensation particle counter (CPC), differential mobility analyzer (DMA), high voltage power supplier (HVPS), and neutralizer. Due to the many components, it is difficult to install a commercial SMPS into a tethered balloon package system (Eun, 2011). In this study, we customized a SMPS for the tethered balloon package system called Hy-SMPS. It is portable, compact in structure, and evaluated by TSI SMPS using mono and poly-dispersed particles.

Effects of Soil Neutralizing Treatments on Soil Characteristics and Growth of Aster koraiensis in the Acid Soil of Abandoned Metal Mine

  • Jung, Mun Ho;Lee, Sang Hwan;Kim, Yoon Su;Park, Mi Jeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.3
    • /
    • pp.287-292
    • /
    • 2016
  • The objectives of this study were to investigate the effects of soil neutralizing treatments on soil characteristics and growth of Aster koraiensis in the acid soil of abandoned metal mine for selection of proper neutralizer. The most effective neutralizers were acid mine drainage sludge, waste lime + oyster and compost. Those neutralizing treatments showed promoting growth of Aster koraiensis. According to this study, it is applicable of acid mine drainage sludge, waste lime + oyster and compost to neutralize acid soil for rehabilitation in abandoned metal mine. However, follow-up study is necessary to calculate proper ratio of each neutralizer.

Study on electrical charge distribution of aerosol using a Gerdien ion counter (Gerdien 이온측정기를 이용한 에어로졸의 하전 특성 분석에 관한 연구)

  • Joe, Yun-Haeng;Shim, Joonmok;Shin, Il-Kyoung;Yook, Se-Jin;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Since the motion of the charged particle strongly depends on its charge characteristics, information on charge distributions of target particles is one of the important variables in aerosol research. In this study, charged distribution of atomized NaCl particles were measured using a Gerdien type ion counter. Two kinds of particle charging conditions were used in this study. First, atomized NaCl particles were passed through an aerosol neutralizer to have a Boltzmann charge distribution, and then its charge distribution was measured. In this case, the portion of uncharged particles was compared with the portion obtained from the Boltzmann charge distribution for verifying the suggested experimental method. Second, same experiment was conducted without the aerosol neutralizer to measure the charge distribution of atomized and un-neutralized NaCl particles. In the conclusion, the portion of uncharged, negatively charged and positively charged particles were 19%, 62% and 20%, respectively, for neutralized particles. The atomized particles, which was generated without the aerosol neutralizer, also had almost a zero charge state, but the standard deviation in charge distribution was larger than that of neutralized particles. The test method proposed in this study is expected to be used in various aerosol research fields because it can obtain simple information on the particle charge characteristics more easily and quickly than the existing test methods.

Dispersion Pattern Simulation of Tungsten Impactors According to Mass and Shape of Explosives (폭약 질량과 형상에 따른 텅스텐 충격자의 분산 패턴 시뮬레이션)

  • Sakong, Jae;Woo, Sung-Choong;Bae, Yong-Woon;Choi, Yeoun-Jin;Cha, Jung-Phil;Ga, In-Han;Kim, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1325-1333
    • /
    • 2014
  • The dispersion pattern of a near miss neutralizer has a great effect on the disablement of a threatening projectile. This study numerically investigated the dispersion pattern of cylindrical tungsten impactors by an explosion in the near miss neutralizer. The mass and shape of the explosive were considered as influencing factors on the dispersion pattern. The explosives were set using two shape models: a parallel shape with the same upper and lower thicknesses and a tapered shape with different upper and lower thicknesses. In the simulation results, the dispersed impactors formed a ring-shaped pattern on a two-dimensional plane in an arbitrary space. In addition, the fire net area increased with the explosive mass when the explosive shapes were identical. In particular, the tapered shape explosive formed a larger fire net area than the parallel shape explosive. Based on the analysis of the fire net area along with the dispersion density, both the explosive mass and shape representing the physical characteristics should be considered for controlling the dispersion pattern of impactors in a near miss neutralizer.

The Ion Generation Characteristics of Charge Neutralizer Applied a Pulse Voltage (펄스전압을 적용한 전하중화장치의 이온발생 특성)

  • Moon, Jae-Duk;Chung, Suk-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.140-146
    • /
    • 1998
  • Methods and systems to remove static electricity are requested necessarily because the static electricity causes a flammable gas explosion, a fire, reduction of production rate in manufacturing VLSI semiconductor device and so on. In this paper, abrasion and dust contaminant of needle electrode are studied experimentally. And, frequencies and pulse durations of a high frequency pulse source were controlled effectively to minimize the abrasion of needle electrode and control generated numbers of ions. As a result, it is verified experimentally that the ion generation of charge neutralizer increases by using a high frequency pulse source.

  • PDF

Effect of Additives on the Viability of Bifidobacteria Loaded in Alginate Poly-l-lysine Microparticles during the Freeze-drying Process

  • Cui, Jing-Hao;Cao, Qing-Ri;Choi, Yun-Jaie;Lee, Kyung-Hoon;Lee, Beom-Jin
    • Archives of Pharmacal Research
    • /
    • v.29 no.8
    • /
    • pp.707-711
    • /
    • 2006
  • Bifidobacteria-loaded alginate poly-l-lysine microparticles (bap microparticles) were prepared using an air atomization method and then freeze-dried. The viability of the bap microparticles was investigated as a function of the amount of the bifidobacteria cultures, and the addition of a yeast extract, cryoprotectants, antioxidants and neutralizer. The size of the bap microparticles with and without the bifidobacteria was $84.8{\pm}28.5\;{\mu}m$ ($mean{\pm}standard$ deviation) and $113.1{\pm}38.5\;{\mu}m$, respectively. The surface morphology was slightly ellipsoid and wrinkled regardless of the incorporating bifidobacteria. The viability gradually decreased with increasing freeze-drying time. Free-flowing powdered bap microparticles were obtained at least 12 h after freeze-drying the wetted slurry of bap microparticles. However, the particles tended to aggregate when either lactose or ascorbic acid was added. The addition of a yeast extract, cryoprotectants (glycerol and lactose), antioxidants ($NaHSO_3$ and ascorbic acid) and neutralizer $(Mg_3(PO_4)_2)$ resulted in a significantly higher viability of the bifidobacteria in the bap microparticles after freeze-drying (0.34-1.84 log) compared with the culture alone.

Assessment of Applicability of a Calcium Carbonate-Alginate Beads as Neutralizer for the High Cell Density Cultivation of Isolated Sourdough Lactic Acid Bacteria (Sourdough에서 분리된 유산균의 고농도 배양을 위한 중화제로서 Calcium Carbonate-Alginate Bead의 이용가능성 평가)

  • Jung, Seung-Won;Lee, Kwang-Geun;Kim, Cheol Woo;Lee, Su Han
    • Food Engineering Progress
    • /
    • v.14 no.3
    • /
    • pp.208-216
    • /
    • 2010
  • Lab scale experiments were conducted in order to assess the applicability of $CaCO_{3}$-alginate beads as neutralizer for the high cell density cultivation and prepare the direct vat inoculation cultures of isolated sourdough lactic acid bacteria. With increasing the amount of bead and decreasing the diameter of bead in acidic solution, the neutralizing effect of $CaCO_{3}$-alginate bead became higher. In batch process with $CaCO_{3}$-alginate beads, Lactobacillus amylovorus DU-21 isolated from sourdough showed the highest viable cell counts and optical density in MRS broth. The values of viable cell counts and optical density were 9.996 log CFU/mL and 3.97, respectively. Experiments on the conditions which increase viability during lyophilization were carried out and the following results were obtained; 15% glycerol revealed the high cryoprotective effect on the concentrated cultures during lyophilization among the two cryoprotective agents. Consequently, $CaCO_{3}$-alginate beads and 15% glycerol were found to be useful not only to cultivate Lactobacillus amylovorus DU-21 but also to preserve strain.

Design of the vacuum pumping system for the KSTAR NBI device (KSTAR 중성빔 입사(NBI) 장치 배기계통 설계)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF