• Title/Summary/Keyword: Neutral-point clamped

Search Result 156, Processing Time 0.017 seconds

A Simplified Synchronous Reference Frame for Indirect Current Controlled Three-level Inverter-based Shunt Active Power Filters

  • Hoon, Yap;Radzi, Mohd Amran Mohd;Hassan, Mohd Khair;Mailah, Nashiren Farzilah;Wahab, Noor Izzri Abdul
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1964-1980
    • /
    • 2016
  • This paper presents a new simplified harmonics extraction algorithm based on the synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level neutral point diode clamped (NPC) inverter-based shunt active power filter (SAPF). The shunt APF is widely accepted as one of the most effective current harmonics mitigation tools due to its superior adaptability in dynamic state conditions. In its controller, the SRF algorithm which is derived based on the direct-quadrature (DQ) theory has played a significant role as a harmonics extraction algorithm due to its simple implementation features. However, it suffers from significant delays due to its dependency on a numerical filter and unnecessary computation workloads. Moreover, the algorithm is mostly implemented for the direct current controlled (DCC) based SAPF which operates based on a non-sinusoidal reference current. This degrades the mitigation performances since the DCC based operation does not possess exact information on the actual source current which suffers from switching ripples problems. Therefore, three major improvements are introduced which include the development of a mathematical based fundamental component identifier to replace the numerical filter, the removal of redundant features, and the generation of a sinusoidal reference current. The proposed algorithm is developed and evaluated in MATLAB / Simulink. A laboratory prototype utilizing a TMS320F28335 digital signal processor (DSP) is also implemented to validate effectiveness of the proposed algorithm. Both simulation and experimental results are presented. They show significant improvements in terms of total harmonic distortion (THD) and dynamic response when compared to a conventional SRF algorithm.

Comparison of Efficiency for Voltage Source and Current Source Based Converters in 5MW PMSG Wind Turbine Systems (전압형 및 전류형 컨버터를 적용한 5MW PMSG 풍력발전시스템의 효율 비교)

  • Kang, Tahyun;Kang, Taewon;Chae, Beomseok;Lee, Kihyun;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.410-420
    • /
    • 2015
  • This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5 MW-class medium-voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for a voltage source type topology, whereas a two-level converter is employed for current source type topology, considering the popularity in the industry. To match the required voltage level of 4160 V with the same switching device of IGCT as in the voltage source converter, two active switches are connected in series for the case of current source converter. Transient thermal modeling of a four-layer Foster network for heat transfer is done to better estimate the transient junction and case temperature of power semiconductors during various operating conditions in wind turbines. The loss analysis is confirmed through PLECS simulations. Comparison result shows that the VSC-based wind turbine system has higher efficiency than the CSC under the rated operating conditions.

Performance Analysis of Grid Connected Back-to-Back Converter Composed of Multi-pulse Converter and PWM Converter (다중펄스 컨버터와 PWM 컨버터로 구성된 Back-to-Back 컨버터의 계통연계 성능 분석)

  • Jeong, Jong-Kyou;Shim, Myong-Bo;Lee, Hye-Yeon;Han, Byung-Moon;Han, Young-Seong;Chung, Chung-Choo;Chang, Byung-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.451-459
    • /
    • 2010
  • This paper describes the performance comparison results for a hybrid back-to-back converter, which is composed of a 3-level 24-pulse converter and a 3-level PWM converter, in order to interconnect a large scale wind farm with the power grid. Also it describes the performance comparison results when the 24-pulse converter operates in only firing-angle control, and both firing-angle and the zero-voltage control. For the purpose of systematic performance comparison, computer simulations with PSCAD/EMTDC software were carried out, and based on simulation results a scaled hardware model with 2 kVA rating was built and tested.

Comparative Study of PI, FNN and ALM-FNN for High Control of Induction Motor Drive (유도전동기 드라이브의 고성능 제어를 위한 PI, FNN 및 ALM-FNN 제어기의 비교연구)

  • Kang, Sung-Jun;Ko, Jae-Sub;Choi, Jung-Sik;Jang, Mi-Geum;Back, Jung-Woo;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.408-411
    • /
    • 2009
  • In this paper, conventional PI, fuzzy neural network(FNN) and adaptive teaming mechanism(ALM)-FNN for rotor field oriented controlled(RFOC) induction motor are studied comparatively. The widely used control theory based design of PI family controllers fails to perform satisfactorily under parameter variation nonlinear or load disturbance. In high performance applications, it is useful to automatically extract the complex relation that represent the drive behaviour. The use of learning through example algorithms can be a powerful tool for automatic modelling variable speed drives. They can automatically extract a functional relationship representative of the drive behavior. These methods present some advantages over the classical ones since they do not rely on the precise knowledge of mathematical models and parameters. Comparative study of PI, FNN and ALM-FNN are carried out from various aspects which is dynamic performance, steady-state accuracy, parameter robustness and complementation etc. To have a clear view of the three techniques, a RFOC system based on a three level neutral point clamped inverter-fed induction motor drive is established in this paper. Each of the three control technique: PI, FNN and ALM-FNN, are used in the outer loops for rotor speed. The merit and drawbacks of each method are summarized in the conclusion part, which may a guideline for industry application.

  • PDF

Novel Switching Table for Direct Torque Controlled Permanent Magnet Synchronous Motors to Reduce Torque Ripple

  • Arumugam, Sivaprakasam;Thathan, Manigandan
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.939-954
    • /
    • 2013
  • The Direct Torque Control (DTC) technique for Permanent Magnet Synchronous Motors (PMSM) is receiving increased attention due to its simplicity and robust dynamic response when compared with other control techniques. The classical switching table based DTC results in large flux and torque ripples in the motors. Several studies have been reported in the literature on classical DTC. However, there are only limited studies that actually discuss or evaluate the classical DTC. This paper proposes, novel switching table / DTC methods for PMSMs to reduce torque ripples. In this paper, two DTC schemes are proposed. The six sector and twelve sector methodology is considered in DTC scheme I and DTC scheme II, respectively. In both DTC schemes a simple modification is made to the classical DTC structure. The two level inverter available in the classical DTC is eliminated by replacing it with a three level Neutral Point Clamped (NPC) inverter. To further improve the performance of the proposed DTC scheme I, the available 27 voltage vectors are allowed to form different groups of voltage vectors such as Large - Zero (LZ), Medium - Zero (MZ) and Small - Zero (SZ), where as in DTC scheme II, all of the voltage vectors are considered to form a switching table. Based on these groups, a novel switching table is proposed. The proposed DTC schemes are comparatively investigated with the classical DTC and existing literatures through theory analysis and computer simulations. The superiority of the proposed DTC method is also confirmed by experimental results. It can be observed that the proposed techniques can significantly reduces the torque ripples and improves the quality of current waveform when compared with traditional and existing methods.

Comparison of Temperature Loss from The Switching Method of Midium Voltage Multilevel Inverter (고압 멀티레벨 인버터의 스위칭 기법에 따른 온도 손실 비교)

  • Lee, Seul-A;Kang, Jin-Wook;Hong, Seok-Jin;Hyun, Seong-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.9-10
    • /
    • 2016
  • 최근 급속한 산업 발달로 인하여 기존의 수 MW급 대용량 인버터가 산업용 팬, 컴프레서, 고속 철도 시스템 등 여러 분야에 사용되면서 이와 관련된 대용량 인버터 연구가 활발히 진행 중이다. 이런 대용량 인버터는 고효율과 직병렬의 구성된 전력용반도체 소자를 동시다발적으로 제어되어야하기 때문에 멀티레벨 인버터의 구조가 가장 적합하다. Cascaded H-bridge 멀티레벨 인버터는 커패시터와 다이오드를 사용하지 않고 스위치만으로 구성하며, 필터를 따로 구성하지 않아도 정현파와 유사하게 전압을 출력할 수 있다. 이로 인해 고주파 감소 및 각 셀을 직렬로 연결하여 입력전압보다 높은 출력전압을 얻을 수 있다. 또한, 스위칭 방법에 따라 동일한 Cascaded H-bridge 멀티레벨인버터 토폴로지에서도 각 THD와 온도에 따른 손실이 달라질 수 있다. Cascaded H-bridge 멀티레벨 인버터에서 이용하는 스위칭 방식은 첫 번째로 유니폴라 방식을 기본으로 한 Phase-shift가 있다. 이는 180도 위상차를 갖는 2개의 레퍼런스 파형과 위상천이가 된 캐리어 파형의 비교로 PWM (Pulse Width Modulation) 을 수행한다. 두 번째 방식으로는 Level-shift가 있다. 이는 캐리어 파형을 IPD (In-Phase Disposition) 방식으로 수직적으로 대역폭이 연속적이게 나열하여 레퍼런스 파형과 비교하는 PWM방식이다. 본 논문에서는 Phase-shift와 Level-shift 방식에 따른 Cascaded H-bridge 인버터와 NPC (Neutral Point Clamped) 인버터를 결합한 토폴로지에서의 온도에 따른 손실을 분석하고, 시뮬레이션을 통하여 비교 분석하였다.

  • PDF