DOI QR코드

DOI QR Code

Comparison of Efficiency for Voltage Source and Current Source Based Converters in 5MW PMSG Wind Turbine Systems

전압형 및 전류형 컨버터를 적용한 5MW PMSG 풍력발전시스템의 효율 비교

  • Kang, Tahyun (Dept. of Electrical Engineering, Smart Grid Research Center, Chonbuk Nat'l University) ;
  • Kang, Taewon (Dept. of Electrical Engineering, Smart Grid Research Center, Chonbuk Nat'l University) ;
  • Chae, Beomseok (Dept. of Electrical Engineering, Smart Grid Research Center, Chonbuk Nat'l University) ;
  • Lee, Kihyun (Dept. of Electrical Engineering, Smart Grid Research Center, Chonbuk Nat'l University) ;
  • Suh, Yongsug (Dept. of Electrical Engineering, Smart Grid Research Center, Chonbuk Nat'l University)
  • Received : 2015.05.07
  • Accepted : 2015.07.14
  • Published : 2015.10.20

Abstract

This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5 MW-class medium-voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for a voltage source type topology, whereas a two-level converter is employed for current source type topology, considering the popularity in the industry. To match the required voltage level of 4160 V with the same switching device of IGCT as in the voltage source converter, two active switches are connected in series for the case of current source converter. Transient thermal modeling of a four-layer Foster network for heat transfer is done to better estimate the transient junction and case temperature of power semiconductors during various operating conditions in wind turbines. The loss analysis is confirmed through PLECS simulations. Comparison result shows that the VSC-based wind turbine system has higher efficiency than the CSC under the rated operating conditions.

Keywords

References

  1. H. J. Lee and S. K. Sul, "Wind power collection and transmission with series connected current source converters," in Proc. 14th EPE, pp. 1-10, Aug. 30-Sep. 1, 2011.
  2. J. Sayago, T. Bruckner, and S. Bernet, "How to select the system voltage of MV drives: A comparison of semiconductor expenses," IEEE Trans. Ind. Electron., Vol. 55, No. 9, pp. 3381-3390, Sep. 2008. https://doi.org/10.1109/TIE.2008.924032
  3. K. Lee, K. Jung, Y. Suh, C. Kim, H. Yoo, and S. Park, "Comparison of high power semiconductor devices losses in 5MW PMSG MV wind turbines," IEEE Applied Power Electronics Conference and Exposition (APEC) , pp. 2511-2518, Mar. 2014.
  4. O. S. Senturk, L. Helle, S. Munk-Nielsen, and P. Rodriguez, "Power capability investigation based on electro-thermal models of press-pack IGBT three-level NPC and ANPC VSCs for multimegawatt wind turbines," IEEE Trans. Power Electron., Vol. 27, No. 7, pp. 3196-3206, Jul. 2012.
  5. F. Filsecker, R. Alvarez, and S. Bernet, "Design and losses of PWM current source converters," in Proc. IEEE Int. Conf. Ind. Technol., pp. 737-744, 2010.
  6. E. P. Wiechmann, P. Aqueveque, R. Burgos, and J. Rodriguez, "On the efficiency of voltage source and current source inverters for high-power drives," IEEE Trans. Ind. Electron., Vol. 55, No. 4, pp. 1771-1782, Apr. 2008. https://doi.org/10.1109/TIE.2008.918625
  7. Y. Suh, J. K. Steinke, and P. K. Steimer, "Efficiency comparison of voltage-source and current-source drive systems for medium-voltage applications," IEEE Trans. Ind. Electron., Vol. 54, No. 5, pp. 2521-2531, Oct. 2007. https://doi.org/10.1109/TIE.2007.900352
  8. P. Tenca, A. A. Rockhill, T. A. Lipo, and P. Tricoli, "Current source topology for wind turbines with decreased mains current harmonics, further reducible via functional minimization," IEEE Trans. Power Electron., Vol. 23, No. 3, pp. 1143-1155, May 2008. https://doi.org/10.1109/TPEL.2008.921183
  9. "Asymmetric integrated gate-commutated thyristor 5SHY 42L6500," Datasheet, Doc. No. 5SYA1245-03 Dec. 12, ABB Switzerland Ltd., Online: www.abb.com.
  10. "Fast recovery diode 5SDF 10H6004," Datasheet, Doc. No. 5SYA1109-03 Jan. 10, ABB Switzerland Ltd., Online: www.abb.com.
  11. L. Clotea and A. Forcos, "Power losses evaluation of two and three-level NPC inverters considering drive applications," in Proc. OPTIM, pp.929-934, 2012.
  12. K. Ma and F. Blaabjerg, "Thermal optimized modulation methods of three-level neutral-pointclamped inverter for 10MW wind turbines under low-voltage ride through," IET Power Electronics, Vol. 5, No. 6, pp. 920-927, 2011. https://doi.org/10.1049/iet-pel.2011.0446
  13. ABB Application Note: 'Applying IGBTs', May 2007.
  14. H. Wang, A. M. Khambadkone, and X. Yu, "Control of parallel connected power converters for low voltage microgrid - Part II: dynamic electrothermal modeling," IEEE Trans. on Power Electronics, Vol. 25, No. 12, pp. 2971-2980, Dec. 2010. https://doi.org/10.1109/TPEL.2010.2087394
  15. J. Dai, D.D. Xu, B. Wu, "A novel control scheme for current-source-converter-based PMSG wind energy conversion systems," IEEE Trans. on Power Electronics, Vol. 24, No. 4, pp. 963-972, Apr. 2009. https://doi.org/10.1109/TPEL.2008.2010259
  16. ABB Switzerland Ltd, http://www.abb.com
  17. GE U.S.A. Ltd, http://www.gepowerconversion.com
  18. Rockwell Automation U.S.A Ltd, http://www.rockwellautomation.com

Cited by

  1. Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines vol.21, pp.3, 2016, https://doi.org/10.6113/TKPE.2016.21.3.238