• 제목/요약/키워드: Neutral wires

검색결과 18건 처리시간 0.022초

전차선로 가선재의 수용액 부식 특성 (The Aqueous Corrosion Characteristics of Catenary Materials of Electric Railway System)

  • 김용기;장세기;조성일;이재봉
    • 한국철도학회논문집
    • /
    • 제4권2호
    • /
    • pp.62-70
    • /
    • 2001
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as catenary materials of the electric railway system. Since these materials may be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important to investigate the corrosion rates in various corrosive environments. The aqueous corrosion characteristics of catenary materials in aerated acid, neutral and alkali solutions were studied by using immersion corrosion tests, electrochemical measurements and analytical techniques. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization, a.c impedance spectroscopy and galvanic corrosion tests were carried out with these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effects on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

Polypyrrole Nanotubules의 합성과 전기적 특성 (Synthesis and Electrical Properties of Polypyrrole Nanotubules)

  • 조영재;김현철;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.544-547
    • /
    • 2000
  • Polypyrrole (PPy) was chemically synthesized within the pores of nanoporous polycarbonate (PC) Particle Track-etched Membranes (nano-PTM). Hollow tubules are formed because polypyrrole initially deposits on the surface of the pores walls. By running successive syntheses, we have obtained wires (filled tubules). The redox property of PPy nanotubules was investigated by cyclic voltammetry. The redox potential was lowered as much as 0.5V vs. Ag/AgC1, comparing with electrosynthesized PPy film. It suggests that an electron hopping mechanism of PPy nanotubules was improved. Electric conductivity of PPy nanotubules and nanowire was evaluated. We obtained good electric conductivity of PPy nanotubules even in the neutral state. The conductivity and activation energy were $10^1$ order at the room temperature and 25.3 meV respectively.

  • PDF

Characteristics of the Plasma Source for Ground Ionosphere Simulation Surveyed by Disk-Type Langmuir Probe

  • Ryu, Kwangsun;Lee, Junchan;Kim, Songoo;Chung, Taejin;Shin, Goo-Hwan;Cha, Wonho;Min, Kyoungwook;Kim, Vitaly P.
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권4호
    • /
    • pp.343-352
    • /
    • 2017
  • A space plasma facility has been operated with a back-diffusion-type plasma source installed in a mid-sized vacuum chamber with a diameter of ~1.5 m located in Satellite Technology Research Center (SaTReC), Korea Advanced Institute of Science and Technology (KAIST). To generate plasma with a temperature and density similar to the ionospheric plasma, nickel wires coated with carbonate solution were used as filaments that emit thermal electrons, and the accelerated thermal electrons emitted from the heated wires collide with the neutral gas to form plasma inside the chamber. By using a disk-type Langmuir probe installed inside the vacuum chamber, the generation of plasma similar to the space environment was validated. The characteristics of the plasma according to the grid and plate anode voltages were investigated. The grid voltage of the plasma source is realized as a suitable parameter for manipulating the electron density, while the plate voltage is suitable for adjusting the electron temperature. A simple physical model based on the collision cross-section of electron impact on nitrogen molecule was established to explain the plasma generation mechanism.

차단기 누적 철분진의 열적특성과 발화위험성 연구 (A Study on the Thermal Characteristics and Fire Hazard of Iron Powder Accumulated on Circuit Break)

  • 김두현;강양현
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.20-25
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics and to study fire hazard of electric leakage by iron power accumulated on circuit breaker in an iron processing factory. The thermal characteristics were analyzed while current was applied to the powder for ten minutes. Results showed that temperature of iron powder at 100 mA is $160^{\circ}C$ and at 175mA is $240^{\circ}C$. The sparks have occurred as iron powder drops between two(hot line and neutral line) wires and then iron powder explosion occurred while dropping continuously the iron powder on two lines. Those who work in the iron processing industry need to periodically remove and maintain the iron powder. The thermal characteristics in this paper can be used for electrical fire investigation and for basic data of thermal characteristic of leakage current through iron powder at iron processing factories.

무정전 결상 보상장치에 관한 연구 (A Study on the Uninterruptible Power Open Phase Compensation Device)

  • 송영주;오진택;김나운;신혜영
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.75-81
    • /
    • 2014
  • It has been widely accepted that open phase may separate one of the power lines from power supply which is mainly caused by fuse melting, malfunction for source circuit breaker, contact failure, and disconnection under normal operating conditions, and is considered a kind of failure mode during disconnection of neutral wires as well. When open phase occurs, unequal voltage between phase might happen in the unbalanced load connected each phase, and further, depending on conditions of load, malfunction by providing low voltage. Moreover, load could be burned or overheated with overvoltage, which, in turn, can be a contributor to starting fires. Accordingly, in order to clearly overcome these problems, the current study aims to introduce the theory of uninterruptible power open phase compensation device, meaning that unbalanced power automatically restores balanced power and provides continuously the power supply without blackout, and verify it through simulation and experiments.

측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정 (Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems)

  • 이복희;엄주홍;김성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF