• 제목/요약/키워드: Neutral voltage

검색결과 363건 처리시간 0.203초

중성점을 가진 단상 PWM 정류기에 관한 연구 (A Study on the Single-Phase PWM Rectifier with Neutral Leg)

  • 최연옥;김평호;한엄용;이진섭;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.675-679
    • /
    • 1999
  • A single-phase PWM current source rectifier with a neutral leg is presented and throughly analyzed in this paper. This novel topology is implemented by adding an extra leg a step-down single phase PWM space vector modulation method to reduce the dc output voltage harmonics is proposed. The PWM pattern generation need a digital system. As compared with a conventional single-phase PWM rectifier, over 20% improvement of the total harmonics distortion in the output voltage can be obtained. Different SVM techniques are analyzed for this PWM rectifier and simulation result are presented.

  • PDF

저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가 (Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges)

  • 이규선;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.67-74
    • /
    • 2010
  • 국내의 저압수용가 대부분은 한국전력공사의 TN-C접지방식으로부터 공급받고 있으나 부하설비는 TT 접지방식을 위주로 한 전기설비기술기준에 따라 시설되어 있다. 본 연구에서는 정보기술설비를 뇌서지로부터 보호할 수 있는 적절한 전원계통접지방식을 제안하기 위해서 TT, TN계통의 뇌서지에 대한 보호성능을 연구하였다. 그 결과, 뇌서지가 배전계통의 중성선에 입사한 때 TT계통의 기기접지단자와 전원선의 중성점 사이에 높은 전위차가 발생하였으며, 예민한 컴퓨터설비가 손상될 위험성이 있으므로 TT계통은 적합하지 않다. 뇌서지로부터 저압 설비를 보호하기 위해서는 등전위본딩이 중요한 요건이며, TN계통이 중성선을 통하여 입사하는 뇌서지의 저감에 가장 우수하였으며, 수용가 인입구에서의 추가접지도 바람직한 방법이다.

승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구 (A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices)

  • 이승원
    • 전기의세계
    • /
    • 제20권4호
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

Neutral Point Balancing Algorithm for Multi-level Converter under Unbalanced Operating Conditions

  • Jung, Kyungsub;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2015
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc link. Based on the zero sequence components of the reference voltages, this paper analyzes the neutral point deviation and balancing control for 3-level NPC converter. An analytical method is proposed to calculate the injected zero sequence voltage for NP balancing based on average neutral current. This paper also proposes a control scheme compensating for the neutral point deviation under generalized unbalanced grid operating conditions. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter. Simulation and experimental results for a test set up of 30kW are shown to verify the validity of the proposed algorithm.

  • PDF

가공 배전선의 전자유도전압에 대하여 대지 귀로전류 원리를 반영한 중성선 차폐계수 계산 방법 (The Calculation Method of Shielding Coefficient of Neutral Line against an Induced Voltage by an Aerial Power Distribution Line Reflecting the Principle of Earth Return Current)

  • 이상무
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.86-91
    • /
    • 2016
  • 가공배전선에 의하여 통신선에 유도되는 전압을 계산하는데에 있어서 기존의 중성선 차폐계수를 단일의 값으로 사용함으로 인한 과다 오차 발생 문제를 해결하기 위하여 실제 배전 구간의 전주 접지 마다 발생하는 누설전류에 의한 대지귀로전류의 영향이 반영된 일반식이 개발된 바 있다. 각 전주 접지에서 발생하는 누설전류의 근원은 중성선에 유입되는 불평형전류이다. 그러므로 누설전류와 그 합인 대지귀로전류는 이 불평형전류에 대한 각 전주 위치에서의 누설율들의 합성적 인수 관계로 표현이 가능하다. 본 논문에서는 결국 원래의 일반식을 누설율의 관점에서 전개하여 좀더 실용적인 의미를 갖도록 하였다. 이렇게 하면 유도의 원천 전류인 중성선 불평형전류에 대한 누설전류 요율만의 합성 인수로 대체된 중성선 차폐계수 계산식이 도출된다. 이 계산식의 의미는 전 배전 구간에서 중성선에 의한 차폐 효과가 일정한 것이 아니라 유도 구간의 위치에 따라서 원래 유도를 발생시키는 전류인 중성선 불평형전류의 양이 달라지는 요율을 말한다는 것이다. 이와 같은 방식으로 계산하였을 때 기존 방식에 비하여 과소 예측에 대하여는 14% 증진율을, 과다 예측에 대하여는 평균 1/10 수준으로의 감소 효과를 기대할 수 있다.

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구 (A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems)

  • 김경철;정지원;이규진;이강수;최선규
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.113-119
    • /
    • 2010
  • 안전한 접지설계는 사고 시에 대지로 고장전류를 흘려보내는 수단과 인체가 사고기기에 접촉 시에 위험에 노출되지 않도록 하는데 있다. 변압기 중성점 접지는 1선 지락사고 시 중성점전위가 허용치 이하가 되도록 접지되어야 한다. 변압기 외함 접지는 절연사고로 외함에 전류가 흐를 때 인체 허용전압과 전류 이내로 저감시키는 목적으로 사용되고 있다. 본 논문에서는 사고 시 중성점 전위와 접촉전압을 계산하여 배전 변압기의 접지저항 영향을 심도있게 분석하였다.

전기철도 단권변압기 중성점 탭절환 특성연구 (Parametric Study for Variable Tap of Autotransformer Neutral in AC Feeding)

  • 한문섭;이장무;김재원;창상훈
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.137-141
    • /
    • 2018
  • The voltage drop is important in electric railway for feeding a huge power of train on fixed feeding area. Nowadays it is tried to operate a high speed trains on conventional lines and there is problem on the voltage drop too. It is simulated on the conditions increased the turn ratio of trolley, installed autotransformer neutral line with variable taps. In result, it is compensated the voltage drop between ATs and better on last AT, not on the position of AT. And it is decreased a return current and neutral current of AT because of unbalance between trolley and feeder. It should be studied faster and more controllable the solid state switchs instead of the mechanical one in order to utilize this system.

소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법 (A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters)

  • 인효철;김석민;박성수;이교범
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

전기수용설비의 중성선 영상분고조파전류저감장치 (A Divece for Reducing the Zero phaze Harmonics of Neutral Line of Power Facility)

  • 강창원;최길수;한성배;김범수;정연해;이기철
    • 전기기술인
    • /
    • 제228권8호
    • /
    • pp.43-48
    • /
    • 2001
  • 우리나라에서는 3 Θ 4w 배전방식을 채택하고 있는데 최근에는 컴퓨터 등 OA 기기 사용증가로 이때 발생하는 영상분 고조파에 의하여 중성선에 상전류 보다 큰 전류가 흐르게 된다. 고조파에 의한 중전선 과전류는 케이블, 변압기, 과열소손, 변압기, 발전기 출력저하, 역률저하, 전력손실 증가, ELB, MCCB 오동작, 유도장해, 중성선 대지전위 상승 등 심각한 장애를 일으키고 있다.

  • PDF