• Title/Summary/Keyword: Neutral valve

Search Result 7, Processing Time 0.025 seconds

Analysis Model Development and Sensitivity Analysis on Design Parameters of the Neutral Valve for HST (HST 중립밸브의 해석모델 개발 및 설계변수 민감도 분석)

  • Kim, D.M.;Jang, J.S.;Kim, S.C.
    • Journal of Drive and Control
    • /
    • v.11 no.3
    • /
    • pp.41-46
    • /
    • 2014
  • The neutral valve for controlling the HST is one of the important valves for the vehicle control. Neutral valve takes a role of blocking or transmitting power to the vehicle. The operating principle of the neutral valve was developed through the analysis model. We also investigated the logical validity by analyzing the results of the analysis model. The analysis model was developed by using SimulationX witch is commercial software. The number of holes in the piston was selected as a variable initial compression of the spring, and the magnitude of the pressure pulsations and the diameter of the orifice for the sensitivity analysis were performed to design sensitivity analysis of the neutral valve.

The Analytic and Experimental Research on Dynamic Characteristics of EMV System (EMV시스템의 동특성 분석을 위한 모델 및 실험적 고찰)

  • 박승현;이종화;김도중;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.85-92
    • /
    • 2002
  • This paper presents the effects of design and operating parameters to meet the static and dynamic performances of the electro-mechanical valve(EMV) actuator which can provide more flexible controllability of valve events compared to conventional variable valve actuation devices. The model of the EMV system was also set up and applied to identify the dynamic behavior of the system. And the effects of external disturbances were also investigated such as cylinder pressure, armature neutral position and current supplying time effects and so on. Experiments were carried out to verify the model using the prototype actuator on test bench, it was found that there is a relatively good agreement between experimental data and modeling results. Also, the actuators meet the general engine speed range (over 6000rpm) and the variable valve event control for various VVT effects.

A Study on the Improvement of the Load Pressure Feedback Mechanism of the Proportional Pressure Control Valve (비례압력제어밸브의 부하압력 피드백방법 개선에 관한 연구)

  • Oh, In-Ho;Jang, Ji-Seongng;Lee, Ill-Yeong;Chung, Dai-Jong;Cho, Sung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.719-726
    • /
    • 1997
  • The proportional pressure control valve having versatile functions and higher performance is an essential conponent in the open loop controlled rear wheel steering gear of the four wheel steering system in a passenger car. In this study, the authors suggest a new type of load pressure feedback mechanism which can make it easy to change the range of controlled pressure without changing the capacity of solenoid. The concept of suggested mechanism, composed of the pressure chamber with throttles in series, was described. The mathematical model was derived from the rear wheel steering gear consisting of a valve and a cylinder for the purpose of analyzing the valve characteristics. And the programme for computing the characteristic of the valve was developed. Experiments were performed to confirm the performance of the valve and computations were carried out to ascertain the usefulness of the developed programme. The results from computations fairly coincide with those from experiments. And the results from experiments and computations show that the performance of new valve was as good as that of the already developed one and the new valve has advantages such as the easiness of changing the range of controlled pressure and the decrease of power loss at neutral position without the decline of performance.

A Study on the Control of Multi-Input Hydraulic System for Robot Leg using LQR Technique (LQR 기법을 이용한 로봇다리의 다중입력 유압시스템 제어에 관한 연구)

  • Yoo, Sam-Hyeon;Lim, Soo-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.540-547
    • /
    • 2009
  • In the near future, military robots are likely to be substituted for military personnel in the field of battle. The power system of a legged robot is considerably more complex than the one used for a land vehicle because of the coordination and stability issues due to the large number of degree of freedom. In this paper, a servovalve-piston combination system for a straight-line motion of robot leg is modeled as three degree of freedom based on double inputs and single output transfer function. The output is the displacement of piston from neutral. The inputs are valve displacement from neutral and arbitrary load force in this system. LQR(Linear Quadratic Regulator) technique is applied in order to achieve robust stability and fast responses of the system. The Kalman filter loop, rejection of disturbance and noise, riccati equation, filter gain matrix, and frequency domain equality are analyzed and designed.

Synchronization Control of Two Hydraulic Cylinders Using Feedback Linearization Compensator and Disturbance Observer (피드백 선형화 보상기와 외란 관측기를 이용한 2개 유압 실린더의 동기 제어)

  • Kam, J.S.;Oh, D.H.;Lee, I.Y.;Kim, J.W.;Lee, H.C.
    • Journal of Drive and Control
    • /
    • v.10 no.3
    • /
    • pp.14-20
    • /
    • 2013
  • In the study, a control strategy using a feedback linearization compensator and a disturbance observer was suggested and applied to the synchronization control of two hydraulic cylinders. The hydraulic system consists of a proportional directional control valve with overlap characteristic near the neutral position, a conventional hydraulic cylinder and an external load. The control performances of the system were verified through numerical simulations. From the simulations, it was ascertained that excellent control performances were obtained with the suggested control strategy.

High Efficiency H-Bridge Multilevel Inverter System Using Bidirectional Switches (양방향 스위치를 이용한 고효율 H-Bridge 멀티레벨 인버터 시스템)

  • Lee, Hwa-Chun;Hwang, Jung-Goo;Kim, Sun-Pil;Choi, Woo-Seok;Lee, Sang-Hyeok;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.16-26
    • /
    • 2014
  • This paper proposes new 13-level inverter topology and DC/DC converter buck-boost structure topology for multilevel, compounding uni-directional and bi-directional switches, and proposes high-efficient multilevel inverter system in which the proposed two PCS(Power Conditioning System) was connected in series. In proposed multilevel inverter of forming a output 13-level phase voltage by using total 18 switching parts, Then bi-directional switch has a characteristic of reducing conduction loss and controlling the reactive power effectively by separating electrically from the neutral point. DC/DC converter for supplying in dependent 3 DC voltage to the proposed multi-level inverter generates 180-degree phase shifted PWM by the symmetrically combined structure of 2 buck-boost converter and twice switching frequency efficiency can be obtained, meanwhile, the converter can step up/down the output voltage and 20% output can be generated comparing the input voltage. This proposed system is verified with the simulation and laboratory test.

Experience and Analysis of Pole Interaction for Jeju HVDC No. 2: Practical Solution for Non-Interruptible Power Transfer (제주 HVDC No. 2의 극간 상호작용 경험과 분석: 무정전 전력 송전을 위한 실용적 해결방안)

  • Kim, Hee-Jin;Kim, Chan-Ki;Park, Chang-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.459-468
    • /
    • 2020
  • The pole interaction of the line-commutated converter high-voltage direct current (HVDC) is analyzed, and a practical solution that uses a surge arrester is proposed. Jeju HVDC No. 2 is a double-monopole HVDC link that has a rated power capacity of 2 × 200 MW and was commissioned in 2012. During normal operation, Jeju HVDC No. 2 is operated in the bipolar mode to minimize the loss caused by the dedicated metallic return. However, when one pole of the inverter valve is bypassed, a commutation failure can occur in the other pole. This phenomenon is called pole interaction in this work. This pole interaction interrupts the HVDC power transfer for almost 2 s and may affect the stability of the power system. This research proposes the installation of a surge arrester at the inverter neutral, which can be an effective and practical solution for pole interaction. The HVDC system is analyzed, and the residual voltage of the surge arrester is determined. Detailed simulation using PSCAD/EMTDC demonstrates that the proposed method eliminates the pole interaction of the bipolar-operated HVDC.