• Title/Summary/Keyword: Neutral Current

Search Result 485, Processing Time 0.029 seconds

Characteristics of the Current Density Induced Inside a Worker Near a Neutral Ground Reactor (중성점 접지 리액터 주변 작업자의 인체내부 유도전류밀도 특성)

  • Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1856-1861
    • /
    • 2010
  • To reduce a high fault current, neutral ground reactors (NGR) were installed in the Korean substation. Current with several harmonic components flows in a NGR due to load unbalance in normal steady state and magnetic fields with several harmonic components are also generated around a NGR. As results of study, we found magnetic fields around a NGR in Korean substation included two harmonics, 180Hz and 540Hz. Magnetic fields of 180 Hz increased 3 times more current density inside a worker near a NGR than same magnitude magnetic fields of 60 Hz. We know a worker near a NGR may not meet ICNIRP guideline of 10(mA/$m^2$) due to several harmonic components.

A Rotor Position Estimation of Brushless DC Motors using Neutral Voltage Compensation Method (중성점전압보상 방식을 이용한 브러시리스직류전동기의 회전자위치 추정)

  • Song Joong-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.491-497
    • /
    • 2004
  • This paper presents a new rotor position estimation method for brushless DC motors. It is clear that the estimation error of the rotor position provokes the phase shift angle misaligned between the phase current and the back-EMF waveforms, which causes torque ripple in brushless DC motor drives. Such an estimation error can be reduced with the help of the proposed neutral voltage-based estimation method that is structured in the form of a closed loop observer. A neutral voltage appearing during the normal mode of the inverter operation is found to be an observable and controllable measure, which can be dealt with for estimating an exact rotor position. This neutral voltage is obtained from the DC-link current, the switching logic, and the motor speed values. The proposed algorithm, which can be implemented easily by using a single DC-link current and the motor terminal voltage sensors, is verified by simulation and experiment results.

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

A Novel Modulation Method for Three-Level Inverter Neutral Point Potential Oscillation Elimination

  • Yao, Yuan;Kang, Longyun;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.445-455
    • /
    • 2018
  • A novel algorithm is proposed to regulate the neutral point potential in neutral point clamped three-level inverters. Oscillations of the neutral point potential and an unbalanced dc-link voltage cause distortions of the output voltage. Large capacitors, which make the application costly and bulky, are needed to eliminate oscillations. Thus, the algorithm proposed in this paper utilizes the finite-control-set model predictive control and the multistage medium vector to solve these issues. The proposed strategy consists of a two-step prediction and a cost function to evaluate the selected multistage medium vector. Unlike the virtual vector method, the multistage medium vector is a mixture of the virtual vector and the original vector. In addition, its amplitude is variable. The neutral point current generated by it can be used to adjust the neutral point potential. When compared with the virtual vector method, the multistage medium vector contributes to decreasing the regulation time when the modulation index is high. The vectors are rearranged to cope with the variable switching frequency of the model predictive control. Simulation and experimental results verify the validity of the proposed strategy.

Technique on the speed up of neutral section in the catenary system (절연구분장치의 속도향상 기술)

  • Chang, Sang-Hoon;Park, Byung-Soo;Kim, Young-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.71-74
    • /
    • 2005
  • At the neutral sections, There are neutral sections inserted in overhead contact line between the substations to divide different phase current sections of AC electrified lines. except convention line, a large stress occurs in the contact wire near the fittings under passing pantographs. So, in order to raise the train speed over 150km/h, a new type section has been adopted.

  • PDF

The study on effect of electric train passing automatic changover system in neutral section of electric railway (절연구간 자동전원 절체시스템을 운행하는 전기차량 영향성 연구)

  • Hong, Hyun-Pyo;Yang, Sang-Woong;Cha, Han-Ju;Kim, Cheol-Hwan;Lee, Hee-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.195-203
    • /
    • 2011
  • This paper is to analysis technical characteristics occured in the eletric train power conversion device passing automatic changover system in neutral section of electric railway. Power conversion devices in electric train are classified according to the current type and voltage type. The results of this study is used to ensure the stability of electric train in neutral section of electric railway.

  • PDF

A Study on the NGR problem for harmonic in Distribution system (배전계통의 고조파에 의한 NGR의 문제점에 관한 연구)

  • Park Hee Chul;Cho Nam Hun;Kang Moon Ho;Wang Young peel
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.480-482
    • /
    • 2004
  • This paper presents a study on the NGR problem for harmonic in distribution systems. Overheating of NGR (Neutral Ground reactor), by neutral current in distribution system, is important cause of transformer breakdown of substation. Countermeasures about zero-sequence component harmonic in neutral line are required.

  • PDF

High Efficiency Control Strategy of TNPC Inverter Using Low-frequency Switching Method of Neutral Point Switch (중성점 스위치의 저주파 스위칭 기법을 이용한 TNPC 인버터의 효율 향상 기법)

  • Lee, Taeyeong;Cho, Younghoon;Lim, Seungbeom
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.329-330
    • /
    • 2015
  • This paper introduces a low-frequency switching method for the neutral line of TNPC inverters to achieve high efficiency. By applying the method, the switching loss in the neutral line is reduced. In order to compensate the current distortion near zero-crossing points, the partial switching strategy is applied. Both the simulation and the experimental results verify the usefulness of the proposed method.

  • PDF

Technique for the Speed Up of Neutral Section on the Convention Line Catenary System (기존선 교류전기철도 절연구분장치에서의 속도향상 기술)

  • Chang, Sang-Hoon;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.294-301
    • /
    • 2008
  • At the neutral sections, There are neutral sections inserted in overhead contact line between the substations to divide different phase current sections of AC electrified lines. Except convention line, a large stress occurs in the contact wire near the fittings under passing pantographs. So, in order to raise the train speed over 150km/h, a new type section has been adopted.

  • PDF