• Title/Summary/Keyword: Neural Recording

Search Result 81, Processing Time 0.027 seconds

Design Optimization of the Air Bearing Surface for the Optical Flying Bead (Optical Flying Head의 Air Bearing Surface 형상 최적 설계)

  • Lee Jongsoo;Kim Jiwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.303-310
    • /
    • 2005
  • The systems with probe and SIL(Solid Immersion Lens) mechanisms have been researched as the technology to perform NFR(Near Field Recording). Most of them use the flying head mechanism to accomplish high recording density and fast data transfer rate. In this paper, ABS shape of flying head was optimized with the object of securing the maximum compliance ability of OFH. We suggest low different optimization processes to predict the static flying characteristics for the OFH. Two different approximation methods, regression analysis and back propagation neural network were used. And we compared the result of directly connected(between CAE and optimizer) method and two approximated optimization results. Design Optimization Tool(DOT) and ${\mu}GA$ were used as the optimizers.

Noise Performance Design of CMOS Preamplifier for the Active Semiconductor Neural Probe (신경신호기록용 능동형 반도체미세전극을 위한 CMOS 전치증폭기의 잡음특성 설계방법)

  • 김경환;김성준
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.477-485
    • /
    • 2000
  • 본 논문에서는 신경신호기록을 위한 반도체 미세전극용 전치증폭기의 잡음특성을 설계하기 위한 체계적인 방법을 제시한다. 세포외기록(extracellular recording)에 의하여 측정된 신경신호와 전형적인 CMOS소자의 저주파 잡음특성을 함계 고려하여 전체 신호대잡음비를 계산하였다. 2단 CMOS 차동증폭기에 대한 해석과 함께 신호대잡음비에 중요한 영향을 끼치는 요소들에 대하여 설명하였다. 출력잡음전력에 대한 해석적인식을 유도하였으며 이로부터 회로설계자가 조절할 수 있는 주파수응답과 소자 파라미터들을 결정하였다. 입력소자의 크기와 트랜스컨덕턴스의 비가 최적영역으로부터 약간 벗어날 경우에 신호대잡음비가 크게 저하됨을 보였다. 이와 함께 만족스런 잡음특성을 위한 증폭이의 설계 변수 값들도 제시하였다.

  • PDF

Design of C-shape Sharp Turn Trajectory using Neural Networks for Fish Robot (신경회로망을 사용한 물고기 로봇의 빠른 방향 전환 궤적 설계)

  • Park, Hee-Moon;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.510-518
    • /
    • 2014
  • In this study, in order to improve and optimize the performance of the turning mechanism for a fish robot in the fluid, we propose the tail joint trajectories using neural networks to mimic the CST(C-shape Sharp Turn) patterns of a real fish which is optimized in the natural environment. In order to mimic the CST patterns of a fish, we convert the sequential recording CST patterns into the coordinate data, and change the numerical coordinate data into a functions. We change the motion functions to the relative joint angles which is adapted to suit robot's shape and data. However, these relative joint trajectories obtained by the sequential recording of the carp have low-precision. It is difficult to apply to the control of a fish robot. Therefore, the relative joint trajectories are interpolated using neural networks with superior generalization ability and applied to the fish robot. we have found that the proposed method using neural networks is superior to ones using high-order polynomial equation through the computer simulations.

In Vitro Biocompatibility Test of Multi-layered Plasmonic Substrates with Flint Glasses and Adhesion Films

  • Kim, Nak-Hyeon;Byun, Kyung Min;Hwang, Seoyoung;Lee, Yena;Jun, Sang Beom
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.174-179
    • /
    • 2014
  • Since in vitro neural recording and imaging applications based on a surface plasmon resonance (SPR) technique have expanded dramatically in recent years, cytotoxicity assessment to ensure the biosafety and biocompatibility for those applications is crucial. Here, we report the cytotoxicity of the SPR substrate incorporating a flint glass whose refractive index is larger than that of a conventional crown glass. A high refractive index glass substrate is essential in neural signal detection due to the advantages such as high sensitivity and wide dynamic range. From experimental data using primary hippocampal neurons, it is found that a lead-based flint glass is not appropriate as a neural recording template although the neuron cells are not directly attached to the toxic glass. We also demonstrate that the adhesion layer between the glass substrate and the gold film plays an important role in achieving the substrate stability and the cell viability.

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.

Miniature PZT actuated microdrive for chronic neural recording in small animals (신경신호 기록을 위한 PZT기반 마이크로 드라이브)

  • Park, Sang-Kyu;Park, Hyun-Jun;Park, Suk-Ho;Kim, Byung-Kyu;Shin, Hee-Sub;Lee, Suk-Chan;Kim, Hui-Su;Kim, Eun-Tai
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.38-40
    • /
    • 2005
  • Microdrive with high precision and light mass enough to install on mouse head was fabricated for recording the reliable signal of neuron cell to understand the brain study. The proposed microdrive has three H-form PZT actuators and its guide structure. The microdrive operation principle is based on the well known inchworm principle. The synchronization of three PZT actuators is able to produce the linear motion along the guide structure. Our proposed microdrive has a precise accuracy of about 100nm and a long stroke of about 5mm. The electrode which is used for the recording of the action potential of the neuron cell was fixed at one of PZT actuators. The proposed microdrive was suited to acquisition of signals from in vivo extra-cellular single-unit recoding. On the condition of the anesthetized mouse, the single-unit signals could be recorded by using the proposed microdrive. In addition, applying the PZT microdrive to an alert mouse, we try to implant it on a mouse brain skull to explore single neuron firing.

  • PDF

Study of Laryngeal Evoked Electromyography Method in Rats (백서를 이용한 후두 유발 근전도 검사 방법에 대한 연구)

  • 조선희;이재연;민선식;신유리;정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.2
    • /
    • pp.178-184
    • /
    • 2000
  • Laryngeal evoked EMG is the objective and quantitative method to measure the innervation of laryngeal muscle. If there is a mobility disorder of vocal cords, the cause and location of neural lesion co be understood by the laryngeal evoked EMG and if there is a vocal cord paralysis, the degree of recovery and the policy of treatment can be determined by it. Recently, the studies of reinnervation after recurrent laryngeal nerve injury have been actively carried out. Laryngeal evoked EMC is useful to these studies. The aim of study is to know whether noninvasive methods for stimulating the recurrent laryngeal nerve and for recording of compound action potential(CAP) using surface electrode are as useful as the invasive method using needle electrode. We obtained EMG of laryngeal muscle by various stimulating and recording methods : 1) Direct nerve stimulation by placing nerve cuff electrode made out of silastic tube and platinum wire and recording by insertion of hook wire electrode into posterior cricoarytenoid(PCA) and thyroarytenoid(TA) muscles, respectively. 2) Recording of compound action potential by surface electrode after stimulation of recurrent laryngeal nerve by the insertion of 27 gauge of needle electrode. 3) Recording of compound action potential by surface electrode after stimulating the recurrent laryngeal nerve by transcutaneous blunt rod electrode at tracheoesophageal groove. The amplitude, duration and latency of the CAP evoked by recurrent laryngeal nerve stimulation were compared among the three groups. The amplitude of CAP was smallest in the group recorded from posterior cricoarytenoid and hyroarytenoid muscle, and that recorded by surface electrode after stimulation by needle electrode was largest. The difference in amplitude between the group by hook wire recording and the two groups by surface electrode recording was significant statistically. There is no significant difference in duration and latency among three groups. Since the waveform of CAP from all three methods has similar duration, latency, we concluded that noninvasive method is a useful as invasive methods.

  • PDF

A Attendance-Absence Checking System using the Self-organizing Face Recognition (자기조직형 얼굴 인식에 의한 학생 출결 관리 시스템)

  • Lee, Woo-Beom
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.72-79
    • /
    • 2010
  • A EAARS(Electronic Attendance-Absence Recording System) is the important LSS(Learning Support System) for blending a on-line learning in the face-to-face classroom. However, the EAARS based on the smart card can not identify a real owner of the checked card. Therefore, we develop the CS(Client-Sever) system that manages the attendance-absence checking automatically, which is used the self-organizing neural network for the face recognition. A client system creates the ID file by extracting the face feature, a server system analyzes the ID file sent from client system, and performs a student identification by using the Recognized weight file saved in Database. As a result, The proposed CS EAARS shows the 92% efficiency in the CS environment that includes the various face image database of the real classroom.

Nonlinear channel equalization using a decision feedback recurrent neural network (결정 궤환 재귀 신경망을 이용한 비선형 채널의 등화)

  • 옹성환;유철우;홍대식
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.9
    • /
    • pp.23-30
    • /
    • 1997
  • In this paper, a decision feedback recurrent neural equalization (DFRNE) scheme is proposed for adaptive equalization problems. The proposed equalizer models a nonlinear infinite impulse response (IIR) filter. The modified Real-Time recurrent Learning Algorithm (RTRL) is used to train the DFRNE. The DFRNE is applied to both linear channels with only intersymbol interference and nonlinear channels for digital video cassette recording (DVCR) system. And the performance of the DFRNE is compared to those of the conventional equalizaion schemes, such as a linear equalizer, a decision feedback equalizer, and neural equalizers based on multi-layer perceptron (MLP), in view of both bit error rate performance and mean squared error (MSE) convergence. It is shown that the DFRNE with a reasonable size not only gives improvement of compensating for the channel introduced distortions, but also makes the MSE converge fast and stable.

  • PDF