• Title/Summary/Keyword: Negative ion

Search Result 575, Processing Time 0.024 seconds

Lower the Detection Limits of Accelerator Mass Spectrometry

  • John A., Eliades;Song, Jong-Han;Kim, Jun-Gon;Kim, Jae-Yeol;O, Jong-Ju;Kim, Jong-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.243-244
    • /
    • 2013
  • Over the past 15 years, several groups have incorporated radio-frequency quadrupole (RFQ) based instruments before the accelerator in accelerator mass spectrometry (AMS) systems for ion-gas interactions at low kinetic energy (<40 eV). Most AMS systems arebased on a tandem accelerator, which requires negative ions at injection. Typically, AMS sensitivity abundance ratios for radioactive-to-stable isotope are limited to Xr/Xs >10^-15, and the range of isotopes that can be analyzed is limited because of theneed to produce rather large negative ion beams and the presence of atomic isobaric interferences after stripping. The potential of using low-kinetic energy ion-gas interactions for isobar suppression before the accelerator has been demonstrated for several negative ion isobar systems with a prototype RFQ system incorporated into the AMS system at IsoTrace Laboratory, Canada (Ontario, Toronto). Requisite for any such RFQ system applied to very rare isotope analysis is large transmission of the analyte ion. This requires proper phase-space matching between the RFQ acceptance and the ion beam phase space (e.g. 35 keV, ${\varphi}3mm$, +-35 mrad), and the ability to control the average ion energy during interactions with the gas. A segmented RFQ instrument is currently being designed at Korea Institute for Science and Technology (한국과학기술연구원, KIST). It will consist of: a) an initial static voltage electrode deceleration region, to lower the ion energy from 35 keV down to <40 eV at injection into the first RFQ segment; b) the segmented quadrupole ion-gas interaction region; c) a static voltage electrode re-acceleration region for ion injection into a tandem accelerator. Design considerations and modeling will be discussed. This system should greatly lower the detection limits of the 6 MV AMS system currently being commissioned at KIST. As an example, current detection sensitivity of 41Ca/Ca is limited to the order of 10^-15 while the 41Ca/Ca abundance in modern samples is typically 41Ca/Ca~10^-14 - 10^-15. The major atomic isobaric interference in AMS is 41K. Proof-of-principal work at IsoTrace Lab. has demonstrated that a properly designed system can achieve a relative suppression of KF3-/41CaF3- >4 orders of magnitude while maintaining very high transmission of the 41CaF3- ion. This would lower the 41Ca detection limits of the KIST AMS system to at least 41Ca/Ca~10^-19. As Ca is found in bones and shells, this would potentially allow direct dating of valuable anthropological archives and archives relevant to our understanding of the most pronounced climate change events over the past million years that cannot be directly dated with the presently accessible isotopes.

  • PDF

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Study of the Influence of Heavy Metal Ions(Cu, Cr, Pb, Zn) on Biochemical Oxygen Demand (BOD 測定에 影響을 미치는 重金屬이온에 關한 연구)

  • Choi, Taek-Pyul;Yun, O-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.9 no.2
    • /
    • pp.75-81
    • /
    • 1983
  • The Biochemical Oxygen Demand(BOD) indicates that microbes are proliferating or that oxygen is being spent by breathing action when examining water under the same aerobic condition. In this research of the mesurement of BOD are the poisonous elements of heavy metal ions such as Cu-ion, Cr-ion, Pb-ion and Zn-ion. They exert an unfavorable influence in the analysis of BOD and research was performed to provide certain data of minimum negative influence by the poisonous matters. The results of the research confirm that heavy metal ion(Cu, Cr, Pb, Zn) do direct an influence upon the normal growth of aerobic microbes in actual tests of chemical analysis of portable water or sewage. The most critical concentration for a negative effect on lowering oxygen quantity and disturbing the aerobic mocrobes normal growth was found to be 0.01 mg/l. Therefore, test results are not valid if the heavy metal concentration is to or greater than 0.0mg/l, To improve comprehension through out the research the author uses the following abbreviations: 1. The Cu-ion is to be excluded before experimental analysis if it is over 0.01mg/l inorder to obtain a real value for the BOD. 2. The Cr-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 3. The Pb-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 4. The Zn-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD.

  • PDF

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Jang, Du-Hui;Park, Min;Kim, Seon-Ho;Jeong, Seung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF

Development and characteristic study of high brightness ion source using inductively coupled plasma for focused ion beam (유도결합 플라즈마를 이용한 집속이온빔용 고휘도 이온원의 개발 및 특성연구)

  • Kim, Yoon-Jae;Park, Dong-Hee;Hwang, Yong-Seok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.494-499
    • /
    • 2004
  • A ion source using inductively coupled plasma has been tested in order to test its feasibility as a high brightness ion source for focused ion beam. When operating the ion source with filter magentas in front of plasma electrode for a negative ion source, lower remittances are expected. Extracted beam remittances are measured with an Allison-type scanning device for various plasma parameters and extraction conditions. The normalized omittance has been measured to be around 0.2$\pi$mmmrad with beam currents of up to 0.55 ㎃. In particular, noting that multicusp magnets have a role in decreasing the remittance as well as increasing plasma discharge efficiency, transverse magnetic field has been confirmed to be a useful tool fur decreasing remittance via electron energy control.

  • PDF

Theoretical Study on Polymerization of Oxepane High Explosives

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.5 no.3
    • /
    • pp.175-181
    • /
    • 2012
  • Oxepane high explosives substituted to explosive group such as azido, nitrato and hydrazino are investigated theoretically the acid catalyzed reaction using the semiempirical MINDO/3, MNDO and AM1 methods to use as the guidelines of high explosives. The nucleophilicity and basicity of oxepane high explosives can be explained by the value of negative charge on oxygen atom of oxepane and the reactivity in propagation step can be represented by the value of positive charge on carbon atom and low electrophile LUMO energy. It was known that carbenium ion was favorable due to the stable energy (19.507~32.101 Kcal/mol) between oxonium ion and carbenium ion in the process of cyclic oxonium ion of oxepane high explosives being converted to open carbenium ion in oxepane high explosives. The value of concentration of cyclic oxonium ion and open carbenium ion in equilibrium status was found to be a major determinant of mechanism, it was expected to react faster in the prepolymer propagation step in SN1 mechanism than in that of $S_N2$.

Density Functional Theory (DFT) Study of Gas-phase O.C Bond Dissociation Energy of Models for o-TEMPO-Bz-C(O)-Peptide: A Model Study for Free Radical Initiated Peptide Sequencing

  • Kwon, Gyemin;Kwon, Hyuksu;Lee, Jihye;Han, Sang Yun;Moon, Bongjin;Oh, Han Bin;Sung, Bong June
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.770-774
    • /
    • 2014
  • The bond dissociation energy (BDE) of the chemical bond between the carbon and oxygen atoms of a simple TEMPO-derivative is calculated by employing the density functional theory, the $2^{nd}$ order M${\phi}$ller-Plesset (MP2) perturbation theory, and complete basis set (CBS) methods. We find that BDE of the positive ion of the TEMPO-derivative is larger at least by 7 kcal/mol than that of the negative ion, which implies that the dissociation reaction rate of the positive ion should be slower than that of the negative ion. Such theoretical predictions are contrary to the results of our previous experiments (Anal. Chem. 2013, 85, 7044), in which the larger energy was required for negative o-TEMPO-Bz-C(O)-peptides to undergo the dissociation reactions than for the positive ones. By comparing our theoretical results to those of the experiments, we conclude that the dissociation reaction of o-TEMPO-Bz-C(O)-peptide should occur in a complicated fashion with a charge, either positive or negative, probably being located on the amino acid residues of the peptide.

Development of a distributed high-speed data acquisition and monitoring system based on a special data packet format for HUST RF negative ion source

  • Li, Dong;Yin, Ling;Wang, Sai;Zuo, Chen;Chen, Dezhi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3587-3594
    • /
    • 2022
  • A distributed high-speed data acquisition and monitoring system for the RF negative ion source at Huazhong University of Science and Technology (HUST) is developed, which consists of data acquisition, data forwarding and data processing. Firstly, the data acquisition modules sample physical signals at high speed and upload the sampling data with corresponding absolute-time labels over UDP, which builds the time correlation among different signals. And a special data packet format is proposed for the data upload, which is convenient for packing or parsing a fixed-length packet, especially when the span of the time labels in a packet crosses an absolute second. The data forwarding modules then receive the UDP messages and distribute their data packets to the real-time display module and the data storage modules by PUB/SUB-pattern message queue of ZeroMQ. As for the data storage, a scheme combining the file server and MySQL database is adopted to increase the storage rate and facilitate the data query. The test results show that the loss rate of the data packets is within the range of 0-5% and the storage rate is higher than 20 Mbps, both acceptable for the HUST RF negative ion source.

Nucleation, Growth and Properties of $sp^3$ Carbon Films Prepared by Direct $C^-$ Ion Beam Deposition

  • Kim, Seong I.
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.173-176
    • /
    • 1997
  • Direct metal ion beam deposition is considered to be a whole new thin film deposition technique. Unlike other conventional thin film deposition processes, the individual deposition particles carry its own ion beam energies which are directly coupled for the formation of this films. Due to the nature of ion beams, the energies can be controlled precisely and eventually can be tuned for optimizing the process. SKION's negative C- ion beam source is used to investigate the initial nucleation mechanism and growth. Strong C- ion beam energy dependence has been observed. Complete phase control of sp3 and sp3, control of the C/SiC/Si interface layer, control of crystalline and amorphous mode growth, and optimization of the physical properties for corresponding applications can be achieved.

  • PDF