• Title/Summary/Keyword: Negative ion

Search Result 579, Processing Time 0.03 seconds

Microstructure and Characterization of Ni-C Films Fabricated by Dual-Source Deposition System

  • Han, Chang-Suk;Kim, Sang-Wook
    • Korean Journal of Materials Research
    • /
    • v.26 no.6
    • /
    • pp.293-297
    • /
    • 2016
  • Ni-C composite films were prepared by co-deposition using a combined technique of plasma CVD and ion beam sputtering deposition. Depending on the deposition conditions, Ni-C thin films manifested three kinds of microstructure: (1) nanocrystallites of non-equilibrium carbide of nickel, (2) amorphous Ni-C film, and (3) granular Ni-C film. The electrical resistivity was also found to vary from about $10^2{\mu}{\Omega}cm$ for the carbide films to about $10^4{\mu}{\Omega}cm$ for the amorphous Ni-C films. The Ni-C films deposited at ambient temperatures showed very low TCR values compared with that of metallic nickel film, and all the films showed ohmic characterization, even those in the amorphous state with very high resistivity. The TCR value decreased slightly with increasing of the flow rate of $CH_4$. For the films deposited at $200^{\circ}C$, TCR decreased with increasing $CH_4$ flow rate; especially, it changed sign from positive to negative at a $CH_4$ flow rate of 0.35 sccm. By increasing the $CH_4$ flow rate, the amorphous component in the film increased; thus, the portion of $Ni_3C$ grains separated from each other became larger, and the contribution to electrical conductivity due to thermally activated tunneling became dominant. This also accounts for the sign change of TCR when the filme was deposited at higher flow rate of $CH_4$. The microstructures of the Ni-C films deposited in these ways range from amorphous Ni-C alloy to granular structures with $Ni_3C$ nanocrystallites. These films are characterized by high resistivity and low TCR values; the electrical properties can be adjusted over a wide range by controlling the microstructures and compositions of the films.

Comparative Study on the Micellization of SDS/Brij 30, DBS/Brij 30, and SDS/DBS Mixed Surfactant Systems in Pure Water (순수 물에서 SDS/Brij 30, DBS/Brij 30 및 SDS/DBS 혼합계면활성제의 미셀화에 대한 비교연구)

  • Lee, Byung-Hwan;Park, In-Jung
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.379-384
    • /
    • 2011
  • The critical micelle concentration (CMC) and the counter ion binding constant (B) for the mixed micellizations of DBS (sodium dodecylbenzenesulfonate), SDS (sodium dodecylsulfate), and Brij 30 (polyoxyethylene(4) lauryl ether) at $25^{\circ}C$ in pure water were determined by the use of electric conductivity and surface tension measuring methods. Various thermodynamic parameters ($X_i,\;{\gamma}i,\;C_i,\;a_i^M,\;{\beta}$, and ${\Delta}H_{mix}$) were calculated and compared with each other mixed surfactant system by means of the equations derived from the nonideal mixed micellar model. The results show that the SDS molecule interacts more strongly with Brij 30 molecule than DBS molecule and that the SDS/Brij 30 mixed surfactant system has the greatest negative deviation from the ideal mixed micellar model and the SDS/DBS mixed system has followed almost the ideal mixed micellar model.

Rate-capability response of graphite anode materials in advanced energy storage systems: a structural comparison

  • Farooq, Umer;Doh, Chil-Hoon;Pervez, Syed Atif;Kim, Doo-Hun;Lee, Sang-Hoon;Saleem, Mohsin;Sim, Seong-Ju;Choi, Jeong-Hee
    • Carbon letters
    • /
    • v.17 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • The work presented in this report was a detailed comparative study of the electrochemical response exhibited by graphite anodes in Li-ion batteries having different physical features. A comprehensive morphological and physical characterization was carried out for these graphite samples via X-ray diffraction and scanning electron microscopy. Later, the electrochemical performance was analyzed using galvanostatic charge/discharge testing and the galvanostatic intermittent titration technique for these graphite samples as negative electrode materials in battery operation. The results demonstrated that a material having a higher crystalline order exhibits enhanced electrochemical properties when evaluated in terms of rate-capability performance. All these materials were investigated at high C-rates ranging from 0.1C up to 10C. Such improved response was attributed to the crystalline morphology providing short layers, which facilitate rapid Li+ ions diffusivity and electron transport during the course of battery operation. The values obtained for the electrical conductivity of these graphite anodes support this possible explanation.

Fluctuation in Plasma Nanofabrication

  • Shiratani, Masaharu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.96-96
    • /
    • 2016
  • Nanotechnology mostly employs nano-materials and nano-structures with distinctive properties based on their size, structure, and composition. It is quite difficult to produce nano-materials and nano-structures with identical sizes, structures, and compositions in large quantities, because of spatiotemporal fluctuation of production processes. In other words, fluctuation is the bottleneck in nanotechnology. We propose three strategies to suppress such fluctuations: employing 1) difference between linear and nonlinear phenomena, 2) difference in time constants, and 3) nucleation as a bottleneck phenomenon. We are also developing nano- and micro-scale guided assembly using plasmas as a plasma nanofabrication.1-5) We manipulate nano- and micro-objects using electrostatic, electromagnetic, ion drag, neutral drag, and optical forces. The accuracy of positioning the objects depends on fluctuation of position and energy of an object in plasmas. Here we evaluate such fluctuations and discuss the mechanism behind them. We conducted in-situ evaluation of local plasma potential fluctuation using tracking analysis of fine particles (=objects) in plasmas. Experiments were carried out with a radio frequency low-pressure plasma reactor, where we set two quartz windows at the top and bottom of the reactor. Ar plasmas were generated at 200 Pa by applying 13.56MHz, 450V peak-to-peak voltage. The injected fine particles were monodisperse methyl methacrylate-polymer spheres of $10{\mu}m$ in diameter. Fine particles were injected into the reactor and were suspended around the plasma/sheath boundary near the powered electrode. We observed binary collision of fine particles with a high-speed camera. The frame rate was 1000-10000 fps. Time evolution of their distance from the center of mass was measured by tracking analysis of the two particles. Kinetic energy during the collision was obtained from the result. Potential energy formed between the two particles was deduced by assuming the potential energy plus the kinetic energy is constant. The interaction potential is fluctuated during the collision. Maximum amplitude of the fluctuation is 25eV, and the average is 8eV. The fluctuation can be caused by neutral molecule collisions, ion collisions, and fluctuation of electrostatic force. Among theses possible causes, fluctuation of electrostatic force may be main one, because the fine particle has a large negative charge of -17000e and the corresponding electrostatic force is large compared to other forces.

  • PDF

Application of multimodal surfaces using amorphous silicon (a-Si) thin film for secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS)

  • Kim, Shin Hye;Lee, Tae Geol;Yoon, Sohee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.384.1-384.1
    • /
    • 2016
  • We reported that amorphous silicon (a-Si) thin film provide sample plate exhibiting a multimodality to measure biomolecules by secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS). Kim et al.1 reported that a-Si thin film were suitable to detect small molecules such as drugs and peptides by SIMS and LDI-MS. Recently, bacterial identification has been required in many fields such as food analysis, veterinary science, ecology, agriculture, and so on.2 Mass spectrometry is emerging for identifying and profiling microbiology samples from its advantageous characters of label-free and shot-time analysis. Five species of bacteria - S. aureus, G. glutamicum, B. kurstaki, B. sphaericus, and B. licheniformis - were sampled for MS analysis without lipid extraction in sample preparation steps. The samples were loaded onto the a-Si thin film with a thickness of 100 nm which did not only considered laser-beam penetration but also surface homogeneity. Mass spectra were recorded in both positive and negative ionization modes for more analytical information. High reproducibility and sensitivity of mass spectra were demonstrated in a mass range up to mass-to-charge ratio(m/z) 1200 by applying the a-Si thin film in mentioned above MS. Principle component analysis (PCA) - a popular statistical analysis widely used in data processing was employed to differentiate between five bacterial species. The PCA results verified that each bacterial species were readily distinguished and differentiated effectively from our MS approach. It shows a new opportunity to rapid bacterial profiling and identification in clinical microbiology. More details will be discussed in the presentation.

  • PDF

The Study of Ibuprofen Degradation Properties by Combination of Wave Energy (Ultrasound, Ultraviolet) and Persulfate Ion (파 에너지 (자외선, 초음파)/과황산나트륨을 이용한 이부프로펜 분해특성 연구)

  • Na, Seungmin;Ahn, Yungyong;Cui, Mingcan;Son, Younggu;Khim, Jeehyeong
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.963-972
    • /
    • 2014
  • In this study, ibuprofen(IBP) degradation by the photochemical ($UV/S_2O{_8}^{2-}$) and sonochemical ($US/S_2O{_8}^{2-}$) processes was examined under various parameters, such as UV ($10{\sim}40{\pm}5W/L$) and US ($50{\sim}90{\pm}5W/L$) power density, optimum dosage of persulfate ion ($S_2O{_8}^{2-}$), temperature ($20{\sim}60^{\circ}C$) and anions effect ($Cl^-$, $HCO_3{^-}$, $CO{_3}^{2-}$). The pseudo-first-order degradation rate constants were in the order of $10^{-1}$ to $10^{-5}min^{-1}$ depending on each processes. The synergistic effect of IBP degradation in $UV/S_2O{_8}^{2-}$ and $US/S_2O{_8}^{2-}$ processes could investigated, due to the generation of $SO_4{^-}$ radical. This result can confirm from the produced $H_2O_2$ and $SO{_4}^{2-}$ concentration in each processes. IBP degradation rate affected by the $S_2O{_8}^{2-}$ dosage, temperature, power and anion existence parameters. In particular, IBP degradation rate increased with the increase of the temperature ($60^{\circ}C$) and applied power density (UV:$40{\pm}5W/L$, US:$90{\pm}5W/L$). On the other hand, anions effect on the IBP degradation was negative, due to the anion play as a the scavenger of radical.

Internal Mixing of Pollutants for Submicron Particles Observed during Springtime in Japan

  • Matsumoto, Jun;Narukawa, Masahiro;Takahashi, Kenshi;Matsumi, Yutaka;Yabushita, Akihiro;Shimizu, Atsushi;Matsui, Ichiro;Sugimoto, Nobuo
    • Asian Journal of Atmospheric Environment
    • /
    • v.3 no.1
    • /
    • pp.27-41
    • /
    • 2009
  • Internally mixed states of submicron particles during transport from the Asian continent to the Pacific Ocean were analyzed using a single-particle time-offlight mass spectrometer. The observation was conducted at Tsukuba in Japan in the spring of 2005 in order to investigate springtime transport of particles from the continent. The sum of ion intensities of sulfate (${HSO_4}^-$) detected in particles originating from the continental air masses counted for 75% of that in all particles during the observation. By analyzing correlations among compounds, origins and internally mixed states of compounds were estimated. It was found that nitrate was mixed with sulfate-rich particles as the air mass approached Japan. It was confirmed that Asian mineral dust particles played significant roles for transport of continental sulfate to Japan. As a result of analysis on internal mixing of chlorine and nitrate, it was implied that the chlorine loss in fine sea salt particles had already proceeded at Tsukuba. It was characteristic that fluoride ions were significantly detected, coal combustion in the Asian Continent can be an important source of fluorides detected in Japan through the westward transportation of fine particles including fluorides.

Cardiac Performance of Turtle Heart in Various pH of Perfusate (자라에서 본 관류액(灌流液) pH와 심장박출량(心臟搏出量))

  • Yang, Il-Suk
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1975
  • Cardiac performances were analyzed in intact turtle heart(Amyda japonica), perfusing with turtle Ringer-Locke's solution containing various hydrogen ion concentration, at several levels of arterial and venous pressure. 1. Ventricular work increased when venous pressure, or venous filling pressure increased, and also increased when arterial pressure increased. 2. The higher the arterial pressure, the lower the cardiac to output, for arterial pressure is the resistance to the ventricular blood flow. On the other hand, in specific arterial pressure, cardiac output was proportional to the venous filling pressure. 3. Heart rates did not change significantly during the perfusion with Ringel· solution of various pH. 4. In the heart Perfused with Ringer solution of various pH, ventricular work was the highest at PH 7.6 (at 6 $cmH_2O$ arterial pressure and 8 $cmH_2O$ venous pressure, the ventricular work was 63.09m$\cdot$cm). However, within the range of pH $7.1{\sim}7.6$, there were no significant changes in cardiac output and ventricular work. Below the level of pH 7.0, ventricular work decreased to less than 56% of maximium value (at $6cmH_2O$ arterial pressure and $8cmH_2O$ venous Pressure, ventricular work was 36.0$gm{\cdot}$ at pH 7.0). At pH 7.7 ventricular work decreased to less than 48% of maximum value (ventricular work: 30.0 $gm{\cdot}$). The nature of the cardiac performance at the various arterial and venous pressures was similar to that of normal heart. 5. Turtle heart seemed to be relatively insensitive to acid-base disturbances. The mechanism of negative inotropic effect of hydrogen ion was discussed.

  • PDF

Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System (PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발)

  • Chung, K.J.;Choe, J.M.;Hwang, H.D.;Kim, G.H.;Ko, K.C.;Hwang, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.246-258
    • /
    • 2006
  • A circuit model has been developed to analyze characteristics of the PSII(plasma source ion implantation) pulse system with dynamic plasma load. The plasma sheath in front of the immersed planar target biased with a negative-high voltage pulse is assumed to be governed by the dynamic Child-Langmuir sheath model. Target current is self-consistently varied with the applied voltage by using the voltage-controlled current source in the circuit model. Circuit simulations are conducted with Pspice circuit simulator, and simulated pulse currents and voltages on the target are compared and confirmed with experimental results for various voltage pulses and plasma conditions.

Dephosphorylation of an Organic Phosphinate by Nucleophile in Anionic and Cationic Micellar Solutions (음이온 및 양이온 미셀 용액에서 친핵체에 의한 유기 포스피네이트의 탈인산화반응)

  • Kim, Jeung-Bea
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.485-491
    • /
    • 2006
  • In the aqueous solutions the dephosphorylations of isopropyl phenyl-4-nitrophenyl phosphinate(IPNPIN) mediated by hydroxide$(OH^{\theta})$ and o-iodosobenzoate$(IB^{\theta})$ ions ate relatively slow, because of hydrophobicity of the substrate, and however it appears that $OH^{\theta}$ is inherently better nucleophile than $IB^{\theta}$, which is more soft ion. On the other hand, in cetyltrimetyiammonium bromide(CTABr) solutions which contain cationic micelles, the dephosphorylations of IPNPIN mediated by $OH^{\theta}$ or $IB^{\theta}$ ate very accelerated to 120 or 100,000 times as compared with those in the aqueous solutions. The values of pseudo first order rate constants reach a maximum with increasing. Such rate maxima are typical of micellar catalysed bimolecular reactions and the rise in rate constant followed by a gradual decrese is characteristic of reactions of hydrophobic substrates. In the cationic micellar solutions of CTABr, $IB^{\theta}$ accelerates the reactions much more than that $OH^{\theta}$ does. The reason seems that $IB^{\theta}$ which is more hydrophobic and soft ion than $OH^{\theta}$ is more easily moved into the Stern layer of the CTABr micelles than $OH^{\theta}$. In the anionic micellar solutions of sodium dodecyl sulfate(SDS), the dephosrhorylations of IPNPIN ate slower than those in aqeous solutions. It means that $OH^{\theta}$ or $IB^{\theta}$ cannot easily move and approach to the Stern layer of the micelle in which almost all the hydrophobic substrate are located and which has a negative circumstance.