• Title/Summary/Keyword: Negative Predictive Value (NPV)

Search Result 87, Processing Time 0.029 seconds

Comparison of the Results for Sentinel Lymph Node Mapping in the Breast Cancer Patients using $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, and $^{99m}Tc$-Human Serum Albumin (유방암 환자에서 $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin을 이용한 감시림프절 매핑 성적의 비교)

  • Jang, Sung-June;Moon, Seung-Hwan;Kim, Seok-Ki;Kim, Bom-Sahn;Kim, Seok-Won;Chung, Ki-Wook;Kang, Keon-Wook;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.546-552
    • /
    • 2007
  • Purpose: In the breast cancer patient, lymphatic mapping and sentinel lymph node biopsy are the most important procedure for axillary lymph node staging. We aimed to compare the three radiocolloids [$^{99m}Tc$-antimony trisulfide colloid (ASC), $^{99m}Tc$-tin colloid (TC), and $^{99m}Tc$-human serum albumin (HSA)] for sentinel lymph node mapping. Subjects and Methods: Totally, 397 patients with clinically N0 stage were enrolled. $^{99m}Tc$-ASC was injected in 202 out of 397 patients, $^{99m}Tc$-TC was injected in 120 patients, and $^{99m}Tc$-HSA was injected in the remaining 75 patients. The sentinel lymph nodes were localized by lymphoscintigraphy and selected using intraoperative gamma probe. All sentinel lymph nodes were investigated by intraoperative pathologic consultation. The axillary lymph nodes which were harvested by the lymph node dissection were also investigated. Results: The patients of each group showed similar clinical characteristics. There were no significant differences (p>0.05) in the identification rate of sentinel lymph nodes (IR), false negative rate (FNR), and negative predictive value (NPV). The axillary lymphadenectomy revealed axillary lymph node metastases in those three groups (ASC-33.2%, TC-31.7%, HSA-22.7%). The IR, FNR, and NPV were not significantly different among those groups. Conclusion: Those three $^{99m}Tc$-labeled radiocolloids showed equivalent results in sentinel lymph node mapping of breast cancer.

Applying the bacterial meningitis score in children with cerebrospinal fluid pleocytosis: a single center's experience

  • Lee, Jungpyo;Kwon, Hyeeun;Lee, Joon Soo;Kim, Heung Dong;Kang, Hoon-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.7
    • /
    • pp.251-255
    • /
    • 2015
  • Purpose: The widespread introduction of bacterial conjugate vaccines has decreased the risk of cerebrospinal fluid (CSF) pleocytosis due to bacterial meningitis (BM) in children. However, most patients with CSF pleocytosis are hospitalized and treated with parenteral antibiotics for several days. The bacterial meningitis score (BMS) is a validated multivariate model derived from a pediatric population in the postconjugate vaccine era and has been evaluated in several studies. In the present study, we examined the usefulness of BMS in South Korean patients. Methods: This study included 1,063 patients with CSF pleocytosis aged between 2 months and 18 years. The BMS was calculated for all patients, and the sensitivity and negative predictive value (NPV) of the test were evaluated. Results: Of 1,063 patients, 1,059 (99.6%) had aseptic meningitis (AM). Only four patients (0.4%) had BM. The majority of patients (98%) had a BMS of ${\leq}1$, indicating a diagnosis of AM. The BMS was 0 in 635 patients (60%) and 1 in 405 patients (38%). All four BM patients had a BMS of ${\geq}4$. Conclusion: To our knowledge, this is the first study to investigate the diagnostic strength of the BMS in South Korea. In our study, the BMS showed 100% sensitivity and 100% NPV. Therefore, we believe that the BMS is a good clinical prediction rule to identify children with CSF pleocytosis who are at a risk of BM.

Safe Discharge Criteria After Curative Gastrectomy for Gastric Cancer

  • Guner, Ali;Kim, Ki Yoon;Park, Sung Hyun;Cho, Minah;Kim, Yoo Min;Hyung, Woo Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.395-407
    • /
    • 2022
  • Purpose: This study aimed to investigate the relationship between clinical and laboratory parameters and complication status to predict which patients can be safely discharged from the hospital on the third postoperative day (POD). Materials and Methods: Data from a prospectively maintained database of 2,110 consecutive patients with gastric adenocarcinoma who underwent curative surgery were reviewed. The third POD vital signs, laboratory data, and details of the course after surgery were collected. Patients with grade II or higher complications after the third POD were considered unsuitable for early discharge. The performance metrics were calculated for all algorithm parameters. The proposed algorithm was tested using a validation dataset of consecutive patients from the same center. Results: Of 1,438 patients in the study cohort, 142 (9.9%) were considered unsuitable for early discharge. C-reactive protein level, body temperature, pulse rate, and neutrophil count had good performance metrics and were determined to be independent prognostic factors. An algorithm consisting of these 4 parameters had a negative predictive value (NPV) of 95.9% (95% confidence interval [CI], 94.2-97.3), sensitivity of 80.3% (95% CI, 72.8-86.5), and specificity of 51.1% (95% CI, 48.3-53.8). Only 28 (1.9%) patients in the study cohort were classified as false negatives. In the validation dataset, the NPV was 93.7%, sensitivity was 66%, and 3.3% (17/512) of patients were classified as false negatives. Conclusions: Simple clinical and laboratory parameters obtained on the third POD can be used when making decisions regarding the safe early discharge of patients who underwent gastrectomy.

Efficacy of Fine Needle Aspiration Biopsy in Parotid Gland Tumors (이하선 종양에서 세침흡인검사의 유용성)

  • Lee, Chang-Hee;Lee, Hyun-Sub;Jin, Sung-Min;Lee, Sang-Hyuk;Pyo, Jung-Soo;Sohn, Jin-Hee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.204-209
    • /
    • 2011
  • Background and Objectives : The usefulness of fine needle aspiration biopsy(FNAB) for diagnosis of parotid gland tumors is controversial, because of the generalized belief requiring surgery for most parotid tumors. The aim of this study was to evaluate the efficacy of FNAB for diagnosis in parotid gland tumors. Material and Methods : FNAB was performed in 91 patients who underwent parotid surgery at Kangbuk Samsung Hospital from January 2007 to December 2010. The result of FNAB, 11 malignancies and 75 benign tumors and 5 non-neoplasms were analyzed and compared with the final histopathologic diagnoses. Sensitivity, specificity, accuracy, positive predictive value(PPV), and negative predictive value(NPV) were calculated using final histopathologic diagnosis of the surgical specimen as the standard diagnostic reference for comparative analysis. Results : 86 specimens(94.5%) were suitable for evaluation. We compared the result of FNAB and the final histopathology in 79(89.4%) cases. The sensitivity, specificity, accuracy, PPV, and NPV of FNAB for detecting pleomorphic adenoma was 95.8%, 88.4%, 92.3%, 90.2%, and 95.0%. In Warthin's tumor, results were 86.4%, 94.2%, 92.3%, 82.6%, and 95.6%. Among 11 patients who were diagnosed with malignancy on final histopathologic report, only 3(30%) patients were diagnosed with the same as on FNAB, the other 8 patients were initially diagnosed incorrectly as benign tumors in FNAB. There were no complications related to FNAB. Conclusion : Diagnostic accuracy for FNAB in benign parotid tumors was high. However, in malignant tumors, FNAB shows low diagnostic usefulness compared with benign tumors. FNAB can be effective and safe diagnostic technique for evaluating the benign parotid glands tumors.

Comparison between Visual Inspection of Cervix and Cytology Based Screening Procedures in Bangladesh

  • Nessa, Ashrafun;Nahar, Khadiza Nurun;Begum, Shirin Akhter;Anwary, Shahin Ara;Hossain, Fawzia;Nahar, Khairun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7607-7611
    • /
    • 2013
  • Background: Cervical cancer continues to be a major problem in Bangladesh with approximately 18,000 new cases annually of which over 10,000 women die from it. Visual inspection of the cervix after 3-5% acetic acid (VIA) application is a simple and easy to learn method for cervical cancer screening, although cytology-based screening is more often applied in developed countries where it has successfully reduced the prevalence of cervical cancer. Objective: To compare the efficacy of VIA and cytology-based primary methods for cervical cancer screening in Bangladesh. Materials and Methods: This hospital based comparative study was conducted at the VIA centre and Colposcopy Clinic of Bangabandhu Sheikh Mujib Medical University (BSMMU) from October 2008 to October 2010. Results: Among 650 women, 74 (11.4%) were VIA+ve and 8 (1.2%) had abnormalities in their Pap smear reports. During colposcopy, 38 (7.7%) women had different grades of CIN and 4 (0.6%) had cervical cancer. The gold standard histology findings proved 20 women had CIN I, 14 had CIN II/II and 4 had cervical cancer. Among the 38 histology diagnosed abnormalities, VIA test could identify 30 abnormalities including two cervical cancers. However, Pap smear could detect only 8 cases of histological abnormalities (2 low grade and 6 had high grade lesion) and it missed all the cervical cancer cases. The sensitivity and specificity of VIA were 88.9% and 52.1%. The positive predictive value (PPV) and negative predictive value (NPV) were 41.0%, and 92.6% respectively. Moreover, the sensitivity, specificity, PPV and NPV of Pap smear were 33.3%, 95.8%, 75.0% and 79.3%, respectively. Conclusions: VIA test should be used as the primary screening tool even with its low sensitivity and specificity in low resource countries like Bangladesh. False positive results may be greater, but overtreatment can be minimized by colposcopy evaluation of the VIA positive women.

Performance of Siriraj Liquid-Based Cytology: a Single Center Report Concerning over 100,000 Samples

  • Sangkarat, Suthi;Laiwejpithaya, Somsak;Rattanachaiyanont, Manee;Chaopotong, Pattama;Benjapibal, Mongkol;Wongtiraporn, Weerasak;Laiwejpithaya, Sujera
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2051-2055
    • /
    • 2014
  • Background: To evaluate the performance of Siriraj liquid-based cytology (LBC) for cervical neoplasia screening after increasing use of this technology. Materials and Methods: Cytological reports of 103,057 Siriraj-LBC specimens obtained in 2007-2009 were compared with those of 23,676 specimens obtained in 2006. Results: Comparing with the year 2006, the 2007-2009 patients were slightly older ($43.4{\pm}12.yr$ vs $42.7{\pm}12.2yr$, p <0.001), and their specimens had much lower proportion of unsatisfactory slides (OR=0.06, 95%CI 0.04-0.09) with comparable detection rates (3.96% vs 3.70%, p=0.052) but different proportions of various cytological abnormalities (p<0.001). The 2007-2009 Siriraj-LBC had a negative predictive value (NPV) for cervical intraepithelial neoplasia 2+ (CIN2+) of 97.6% and an overall positive predictive value (PPV) of 43.9%. The PPV for CIN2+ varied with types of abnormal cytology, from 13.7% to 93.8% in atypical squamous cells of undetermined significance (ASCUS), low-grade squamous intraepithelial lesion (LSIL), atypical squamous cells cannot exclude HSIL (ASC-H), high-grade squamous intraepithelial lesion (HSIL), atypical glandular cells (AGC), to squamous cell carcinoma (SCC), respectively. The PPVs for CIN2+ in ASCUS and LSIL were comparable, but the PPV for CIN1 was higher for LSIL than for ASCUS (41.63% vs 16.32%). Conclusions: Siriraj-LBC has demonstrated a stable detection rate and NPV for CIN2+ of >95% since the first year of use. The comparable PPVs for CIN2+ of ASCUS and LSIL suggests that these two conditions may undergo similar management; other cytological abnormalities need immediate evaluation.

Roles of Sonography and Hysteroscopy in the Detection of Premalignant and Malignant Polyps in Women Presenting with Postmenopausal Bleeding and Thickened Endometrium

  • Cavkaytar, Sabri;Kokanali, Mahmut Kuntay;Ceran, Ufuk;Topcu, Hasan Onur;Sirvan, Levent;Doganay, Melike
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5355-5358
    • /
    • 2014
  • Background: To assess the role of sonographic endometrial thickness and hysteroscopic polyp size in predicting premalignant and malignant polyps in postmenopausal women. Materials and Methods: A total of 328 postmenopausal women with abnormal uterine bleeding and thickened endometrium underwent operative hysteroscopy due to detection of endometrial polyps were included in this retrospective study. Preoperative endometrial thickness measured by transvaginal ultrasonography and polyp size on hysteroscopy were noted. Hysteroscopic resection with histology was performed for endometrial polyps. Endometrial thickness and polyp size were evaluated on the basis of final diagnosis established by histologic examination. Receiver operator characteristic curves were calculated to assess the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of endometrial thickness and polyp size for detecting pemalignant and malignant polyps. Results: Premalignant and malignant polyps were identified in 26 (7.9%) of cases. Sonographic measurement showed a greater endometrial thickness in cases of premalignant and malignant polyps when compared to benign polyps. On surgical hysteroscopy, premalignant and malignant polyps were also larger. Endometrial thickness demonstrated a sensitivity of 53.8%, specificity of 85.8%, PPV of 24.6% and NPV of 95.6% at a cut-off limit of 11.5 mm with diagnostic accuracy of 83.2%. Polyp size has a diagnostic accuracy of 94.8% with a sensitivity of 92.3%, specificity of 95.0%, PPV of 61.5% and NPV of 99.3% at a cut-off point of 19.5mm. Conclusions: Endometrial thickness measured by transvaginal ultrasonography is not sufficient in predicting premalignant and malignant endometrial polyps in postmenopausal women with abnormal uterine bleeding and thickened endometrium. Polyp size on hysteroscopy is a more accurate parameter, because of better sensitivity and specificity. However, while polyp size ${\geq}19.5mm$ seems to have a great accuracy for predicting premalignancy and malignancy, histologic evaluation is still necessary to exclude premalignant and malignant polyps.

Prostate Imaging-Reporting and Data System: Comparison of the Diagnostic Performance between Version 2.0 and 2.1 for Prostatic Peripheral Zone

  • Hyun Soo Kim;Ghee Young Kwon;Min Je Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1100-1109
    • /
    • 2021
  • Objective: To compare the diagnostic performance between Prostate Imaging-Reporting and Data System version 2.0 (PI-RADSv2.0) and version 2.1 (PI-RADSv2.1) for clinically significant prostate cancer (csPCa) in the peripheral zone (PZ). Materials and Methods: This retrospective study included 317 patients who underwent multiparametric magnetic resonance imaging and targeted biopsy for PZ lesions. Definition of csPCa was International Society of Urologic Pathology grade ≥ 2 cancer. Area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for csPCa were analyzed by two readers. The cancer detection rate (CDR) for csPCa was investigated according to the PI-RADS categories. Results: AUC of PI-RADSv2.1 (0.856 and 0.858 for reader 1 and 2 respectively) was higher than that of PI-RADSv2.0 (0.795 and 0.747 for reader 1 and 2 respectively) (both p < 0.001). Sensitivity, specificity, PPV, NPV, and accuracy for PI-RADSv2.0 vs. PI-RADSv2.1 were 93.2% vs. 88.3% (p = 0.023), 52.8% vs. 76.6% (p < 0.001), 48.7% vs. 64.5% (p < 0.001), 94.2% vs. 93.2% (p = 0.504), and 65.9% vs. 80.4% (p < 0.001) for reader 1, and 96.1% vs. 92.2% (p = 0.046), 34.1% vs. 72.4% (p < 0.001), 41.3% vs. 61.7% (p < 0.001), 94.8% vs. 95.1% (p = 0.869), and 54.3% vs. 78.9% (p < 0.001) for reader 2, respectively. CDRs of PI-RADS categories 1-2, 3, 4, and 5 for PI-RADSv2.0 vs. PI-RADSv2.1 were 5.9% vs. 5.9%, 5.8% vs. 12.5%, 39.8% vs. 56.2%, and 88.9% vs. 88.9% for reader 1; and 4.5% vs. 4.1%, 6.1% vs. 11.1%, 32.5% vs. 53.4%, and 85.0% vs. 86.8% for reader 2, respectively. Conclusion: Our data demonstrated improved AUC, specificity, PPV, accuracy, and CDRs of category 3 or 4 of PI-RADSv2.1, but decreased sensitivity, compared with PI-RADSv2.0, for csPCa in PZ.

Diagnosis of Scoliosis Using Chest Radiographs with a Semi-Supervised Generative Adversarial Network (준지도학습 방법을 이용한 흉부 X선 사진에서 척추측만증의 진단)

  • Woojin Lee;Keewon Shin;Junsoo Lee;Seung-Jin Yoo;Min A Yoon;Yo Won Choi;Gil-Sun Hong;Namkug Kim;Sanghyun Paik
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1298-1311
    • /
    • 2022
  • Purpose To develop and validate a deep learning-based screening tool for the early diagnosis of scoliosis using chest radiographs with a semi-supervised generative adversarial network (GAN). Materials and Methods Using a semi-supervised learning framework with a GAN, a screening tool for diagnosing scoliosis was developed and validated through the chest PA radiographs of patients at two different tertiary hospitals. Our proposed method used training GAN with mild to severe scoliosis only in a semi-supervised manner, as an upstream task to learn scoliosis representations and a downstream task to perform simple classification for differentiating between normal and scoliosis states sensitively. Results The area under the receiver operating characteristic curve, negative predictive value (NPV), positive predictive value, sensitivity, and specificity were 0.856, 0.950, 0.579, 0.985, and 0.285, respectively. Conclusion Our deep learning-based artificial intelligence software in a semi-supervised manner achieved excellent performance in diagnosing scoliosis using the chest PA radiographs of young individuals; thus, it could be used as a screening tool with high NPV and sensitivity and reduce the burden on radiologists for diagnosing scoliosis through health screening chest radiographs.

Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density

  • Haejung Kim;So Yeon Yang;Joong Hyun Ahn;Eun Young Ko;Eun Sook Ko;Boo-Kyung Han;Ji Soo Choi
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1031-1043
    • /
    • 2022
  • Objective: To compare digital breast tomosynthesis (DBT) and MRI as an adjunct to full-field digital mammography (FFDM) for the preoperative evaluation of women with breast cancer based on mammographic density. Materials and Methods: This retrospective study enrolled 280 patients with breast cancer who had undergone FFDM, DBT, and MRI for preoperative local tumor staging. Three radiologists independently sought the index cancer and additional ipsilateral and contralateral breast cancers using either FFDM alone, DBT plus FFDM, or MRI plus FFDM. Diagnostic performances across the three radiologists were compared among the reading modes in all patients and subgroups with dense (n = 186) and non-dense breasts (n = 94) according to mammographic density. Results: Of 280 patients, 46 (16.4%) had 48 additional (39 ipsilateral and nine contralateral) cancers in addition to the index cancer. For index cancers, both DBT plus FFDM and MRI plus FFDM showed sensitivities of 100% in the non-dense group. In the dense group, DBT plus FFDM showed lower sensitivity than that of MRI plus FFDM (94.6% vs. 99.6%, p < 0.001). For additional ipsilateral cancers, DBT plus FFDM showed specificity and positive predictive value (PPV) of 100% in the non-dense group, but sensitivity and negative predictive value (NPV) were not statistically different from those of MRI plus FFDM (p > 0.05). In the dense group, DBT plus FFDM showed higher specificity (98.2% vs. 94.1%, p = 0.005) and PPV (83.1% vs. 65.4%; p = 0.036) than those of MRI plus FFDM, but lower sensitivity (59.9% vs. 75.3%; p = 0.049). For contralateral cancers, DBT plus FFDM showed higher specificity than that of MRI plus FFDM (99.0% vs. 96.7%, p = 0.014), however, the other values did not differ (all p > 0.05) in the dense group. Conclusion: DBT plus FFDM showed an overall higher specificity than that of MRI plus FFDM regardless of breast density, perhaps without substantial loss in sensitivity and NPV in the diagnosis of additional cancers. Thus, DBT may have the potential to be used as a preoperative breast cancer staging tool.