• 제목/요약/키워드: Negative Impedance

Search Result 161, Processing Time 0.029 seconds

Multiple-Mode Structural Vibration Control Using Negative Capacitive Shunt Damping

  • Park, Chul-Hue;Park, Hyun-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1650-1658
    • /
    • 2003
  • This paper deals with a novel shunt circuit, which is capable of suppressing multimode vibration amplitudes by using a pair of piezoceramic patches. In order to describe the characteristic behaviors of a piezoelectric damper connected with a series and a parallel resistor-negative capacitor branch circuit, the stiffness ratio and loss factor with respect to the non-dimensional frequency are considered. The mechanism of the shunt damper is also described by considering a shunt voltage constrained by shunt impedance. To obtain a guideline model of the piezo/beam system with a negative capacitive shunting, the governing equations of motion are derived through the Hamilton's principle and a piezo sensor equation as well as a shunt-damping matrix is developed. The theoretical analysis shows that the piezo/beam system combined with a series and a parallel resistor-negative capacitor branch circuit developed in this study can significantly reduce the multiple-mode vibration amplitudes over the whole structural frequency range.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

A New Simple Sensorless Control Method for Switched Reluctance Motor Drives

  • Xin Kai;Zhan Qionghua;Luo Jianwu
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.52-57
    • /
    • 2006
  • In this paper, a new 'impedance sensing' method is described. This method overcomes the shortcomings of the impedance sensing method. According to the new method, sensing voltage pulse is applied to the idle phase in the minimum inductance region and the beginning of the increasing inductance region to detect rotor position. The negative torque produced by the sensing voltage pulse can be neglected in the minimum inductance region and the efficiency of SRM is improved. In the minimum inductance region the back electromotive force (EMF) can be neglected. And in the increasing inductance region the EMF opposes the rise of current in the phase, so the position estimation scheme is reliable. Therefore the new 'impedance sensing' method is sufficiently precise even under the high back EMF effect. The adjustment of turn-on angle and turn-off angle is also easy to be realized. The technique is very useful in applications where cost or size is primary concerns, such as electric bicycle drives. Experimental results are presented to verify the proposed method.

Structural and electrical properties of lead free ceramic: Ba(Nd1/2Nb1/2)O3

  • Nath, K. Amar;Prasad, K.;Chandra, K.P.;Kulkarni, A.R.
    • Advances in materials Research
    • /
    • v.2 no.2
    • /
    • pp.119-131
    • /
    • 2013
  • Impedance and electrical conduction studies of $Ba(Nd_{1/2}Nb_{1/2})O_3$ ceramic prepared using conventional high temperature solid-state reaction technique are presented. The crystal symmetry, space group and unit cell dimensions were estimated using Rietveld analysis. X-ray diffraction analysis indicated the formation of a single-phase cubic structure with space group $Pm\bar{3}m$. Energy dispersive X-ray analysis and scanning electron microscopy studies were carried to study the quality and purity of compound. The circuit model fittings were carried out using the impedance data to find the correlation between the response of real system and idealized model electrical circuit. Complex impedance analyses suggested the dielectric relaxation to be of non-Debye type and negative temperature coefficient of resistance character. The correlated barrier hopping model was employed to successfully explain the mechanism of charge transport in $Ba(Nd_{1/2}Nb_{1/2})O_3$. The ac conductivity data were used to evaluate the density of states at Fermi level, minimum hopping length and apparent activation energy.

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

Influence of Cardiac Contraction and its Phase Angle with Coronary Blood flow on Atherosclerosis of Coronary Artery (심장의 수축운동과 관상동맥 혈류와의 위상차가 관상동맥 혈관의 동맥경화 민감성에 미치는 영향)

  • 김민철;이종선;김찬중;권혁문
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.437-449
    • /
    • 2002
  • Coronary arteries are subjected to very different flow conditions compared to other arteries in systemic blood circulation. We Performed a computational fluid dynamic research to investigate influence of such flow conditions in coronary arteries on development and progress of atherosclerosis in the same. The results showed big differences in the flow field of the coronary artery compared to the abdominal and femoral arteries. The coronary artery showed higher wall shear stresses due to the small vessel diameter. On the other hand, it showed only one vortex distal to the stenosis throat during a whole pulse cycle. However. several vortices were observed in the abdominal and femoral arteries in both proximal and distal sides of the stenosis throat The wall shear stresses and extent of recirculation area were increased with impedance phase angle increasing toward more negative values. Therefore, cardiac contraction and the negative impedance phase angle as large as -110。 may induce a flow field that accelerates atherosclerosis.

Anti-islanding Detection of Photovoltaic Inverter Based on Negative Sequence Voltage Injection to Grid (역상분 전압 주입을 이용한 태양광 인버터의 단독 운전 검출)

  • Kim, Byeong-Heon;Park, Yong-Soon;Sul, Seung-Ki;Kim, Woo-Chull;Lee, Hyun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.546-552
    • /
    • 2012
  • This paper presents an active anti-islanding detection method using negative sequence voltage injection to the grid through a three-phase photovoltaic inverters. Because islanding operation mode can cause a variety of problems, the islanding detection of grid-connected photovoltaic inverter is the mandatory feature. The islanding mode is detected by measuring the magnitude of negative sequence impedance calculated by the negative sequence voltage and current at the point of common coupling. Simulation and experimental test are performed to verify the effectiveness of the proposed method which can detect the islanding mode in the specified time. The test has been done in accordance with the condition on IEEE Std 929-2000.

Impedance Characteristics of the Gel Type VRLA Battery at the Various State-of-Charge (겔식 납축 전지의 충전상태에 따른 임피던스 특성 연구)

  • An, Sang-Yong;Jeong, Euh-Duck;Won, Mi-Sook;Shim, Yoon-Bo
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.33-36
    • /
    • 2008
  • In the present study, impedance spectrometry has been used for predicting State-of-Charge (SoC) of gel type, Valve Regulated Lead Acid (VRLA), battery. The impedance measurements of VRLA battery (2V/1.2 Ah) at various SoC were made over the frequency range from 100kHz to 10mHz with an amplitude 10 mV. The impedance parameters have been evaluated by the analysis of the data using an equivalent circuit and a complex non-linear least squares (CNLS) fitting method. The charge transfer resistance values and double layer capacitance values of the positive electrode were higher than those of the negative electrode. The gel resistance values increased with decreasing in SoC. This indicates that the gel resistance is an important parameter for predicting SoC of VRLA battery.

Analysis of Negative Resistance Maximum Oscillating Frequeney (부저항발진기의 최대주파수 해석(I보))

  • 김영권;서정홍
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.2
    • /
    • pp.6-20
    • /
    • 1969
  • Tunnel diode oscillator consisting of a tunnel diode(negative-resistance element) and a passive linear load. In this paper maximizing the frequeney of a negative reistance oscillator with varying a passive linear load is investigated. The method of theoretical analysis, utiliying impedance loei in the complex plane and experimental data shows that the maximum frequencies of quasi-harmonic oscillation is higher in the parrallal-RL load than in the resistive load.

  • PDF