• Title/Summary/Keyword: Negative Impedance

Search Result 161, Processing Time 0.026 seconds

Design and Implementation of Local Oscillator for X-Band Radar (X-대역 레이더용 국부 발진기의 설계 및 구현)

  • Kim, Gi-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1215-1220
    • /
    • 2014
  • In this paper, a local oscillator for X-band radar system is designed and fabricated with GaAs MESFET. GaAs MESFET is good for microwave oscillators because of very low noise figure and high electron mobility. Oscillator design methods in this paper are used the characteristic of negative resistance of active component and impedance matching technique without RF resonator. So, oscillator is designed in compact size because space of RF resonator is reduced and can be applied MMIC technique. Designed oscillator has characteristic of the output power of 2.30 dBm and center frequency of 10.545GHz.

Correlation between Obesity and Lumbar Lordosis in Obese Pre-Menopausal Korean Females

  • Song Mi-Yeon;Chung Won-Suk;Kim Sung-Soo;Shin Hyun-Dae
    • The Journal of Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.43-50
    • /
    • 2004
  • Objective : Obesity is associated with degenerative arthropathy giving stress on joints. It also amplifies loads of weight bearing joints by changing the gravity line of the body. Our aim is to investigate the correlation between obesity and lumbar lordosis in obese pre-menopausal Korean females. The hypothesis was tested that there is a correlation between obesity and lumbar lordosis. Methods : A cross-sectional evaluation of 44 Females (baseline age 30.77 ± 6.46) with BMI 31.53 ± 3.82 (kg/㎡) was done. Body composition was measured using bio-impedance analysis (BIA), and anthropometry was done by the same observer. A lateral whole spine X-ray was taken in standing position to measure the lumbar lordotic angle (LLA), Ferguson angle (FA) and lumbar gravity line (LGL). A Pearson correlation was used to measure the correlation between obesity and lumbar lordosis (SPSS 10.0 for windows). Results : Body mass index (BMI kg/㎡) had a negative relationship with LLA((equation omitted)=-0.469), FA((equation omitted) =-0.347) and LGL((equation omitted)=-0.389). Body fat rate had a negative relationship with LLA only(γ=-0.385). Waist circumference had a negative relationship with LLA((equation omitted)=-0.345) and LGL((equation omitted)=-0.346). WH ratio had no relationship with lumbar lordosis. Conclusion : These data show that obesity is related to mechanical structures, such as lumbar lordosis. BMI was the most useful index, which reflects a change of mechanical structure of lumbar, more than other variables in this study.

  • PDF

A Study on Synthesis of The Low Pass NIC Filter (Low Pass NIC Filter 설계에 관한 고찰)

  • 이정한;이영수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.1
    • /
    • pp.13-21
    • /
    • 1967
  • A low pass filter is synthesized with R, C and negative impedance converters(NIC). The filter has a 4-th order elliptic function, which gives best magnitude approximation with equi-ripple characteristics both in pass and stop band. And experimental investigations have been made on the effect of the anticipated deviation of the NIC conversion factor and of possible loaded operation. Through the study, it has been cocluded that: 1. For minimum pole-zero sensitivity with respect to the NIC conversion factor, the network of a parallel RC-NIC configuration is preferable and the Horowitz polynomial decomposition method is applied in the synthesis procedure. 2. A few percentage variation of the NIC conversion factor changes the frequency and amplitude characteristics of the filter by nearly negligible amount. 3. With a load resistance below the critical value, the filter turns into an oscillator.

  • PDF

Investigation on Quality Factor Control Method of Piezoelectric Vibrator for Ultrasonic Transducer (초음파 트랜스듀서용 압전 진동자의 품질계수 제어 법 검토)

  • Ko Young-In;Kim Moo-Joon;Ha Kang-Lyeol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.369-372
    • /
    • 2000
  • PZT 세라믹 트랜스듀서와 같은 압전 세라믹 진동자를 사용하는데 있어서 품질계수(quality factor)를 제어할 수 있다는 것은 전기-기계 결합계수나 삽입손실 등을 개선 할 수 있으므로 매우 유용한 것이다 본 연구에서는 압전 진동자의 품질계수를 제어하는 방법으로써 압전 진동자의 제동용량과 저항성분을 전기적으로 상쇄시킬 수 있는 부임피던스 변환회로(negative impedance converter circuit)를 적용하였다. 그 결과 부임피던스 변환회로를 적용하지 않은 경우에 비해 압전 진동자의 품질계수가 수십 배정도 까지 제어됨을 실험으로 확인하였다.

  • PDF

Studies on Enhanced Oxidation of Estrone and Its Voltammetric Determination at Carbon Paste Electrode in the Presence of Cetyltrimethylammonium Bromide

  • Yang, Chunhai;Xie, Pingping
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1729-1734
    • /
    • 2007
  • The electrochemical behaviors of estrone in the presence of various surfactants were examined with great details. It is found that a cationic surfactant, cetyltrimethylammonium bromide (CTAB), obviously facilitates the electro-oxidation of estrone at carbon paste electrode (CPE) from the significant peak current enhancement and the negative shift of peak potential. Additionally, chronocoulometry and electrochemical impedance spectroscopy (EIS) were also used for further investigation of the electrode process of estrone, indicating that low concentration of CTAB exhibits excellent enhancement effects on the electrochemical oxidation of estrone, greatly enhances the diffusion coefficient and the electron transfer rate. Based on this, an electrochemical method was proposed for the determination of estrone. The oxidation peak current is proportional to the concentration of estrone in the ranges over 9.0 × 10?8 - 8.0 × 10?6 mol/L, and a low detection limit of 4.0 × 10?8 mol/L was obtained for 180s accumulation at open circuit (S/N = 3). Finally, this proposed method was demonstrated using estrone tablets with good satisfaction.

Microwave Transistor Oscillator by Cavity Rexsonator (캐비티 동조에 의한 마이크로파 트란지스터 발진기)

  • 장익수;김병철
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.5
    • /
    • pp.20-25
    • /
    • 1982
  • A realization method of the microwave oscillator is proposed by the inherently stable transistor with a cavily resonator feedback loop. The real Part of the output impedance of the inherently stable bipolar transistor can be made to be negative at the resonance frequency by the high-Q cavity feedback loop, and the oscillation condition can be obtained with the matching section of the load. In this work the microwave transistor oscillator is realized with a silicon bipolar transistor HXTR 2101 and a reentrani cavity, and characteristic of the output power 10m Watts at 2.33 GHz osc. frequency can be verified experimentally.

  • PDF

Correlated effects of decoupling capacitors and vias loaded in the PCB power-bus (PCB power-bus에 장하된, 결합제거 커패시터와 금속선의 상관관계적 영향 연구)

  • Kahng, Sung-Tek
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.429-432
    • /
    • 2005
  • This paper investigates how the PCB power-bus structure's characteristics are influenced by the loading of decoupling capacitors that are placed close to vias, on purpose or not. It is worthwhile to see the correlated effects of the aforementioned lumped elements in that when they inevitably share one DC power-bus they will result in positive or negative changes in the PCB EMC design. The EM fields and impedance profiles are rigously calculated on the PCB power-bus cases loaded with the above components and their effects will be given to bring better PCB EMC countermeasures.

  • PDF

Control of the Subsystem for a Power System (전력시스템을 위한 서브시스템의 제어)

  • Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.404-409
    • /
    • 2009
  • A DC power system has many loads with various functions. In particular, these sizable loads take the form of power electronic converters. When they are tightly regulated, the loads appear as constant power loads and result in negative incremental input impedance. Under certain conditions the effect of such loads on the power system is causes instability. In this paper, converter with a large storage capacitor and a lag compensator is proposed as a DC bus conditioner to mitigate the voltage transients on the bus. In addition, the proposed control approach has the advantage of performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Simulation and experimental results showed that the proposed control method was operated well in a small-scale DC power system that contained subsystems with constant power characteristics, such as DC/DC converters and electrical drives.

Fault Location Algorithm with Ground Capacitance Compensation for Long Parallel Transmission Line (장거리 병렬 송전선로용 대지 정전용량 보상에 의한 고장점 표정 알고리즘)

  • Park, Chul-Won;Kim, Sam-Ryong;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • This paper deals with an improved fault location algorithm with compensation ground capacitance through distributed parameter for a long parallel T/L. For the purpose of fault locating algorithm non-influenced by source impedance and fault resistance, the loop method was used in the system modeling analysis. This algorithm uses a positive and negative sequence of the fault current for high accuracy of fault locating calculation. Power system model of 160km and 300km long parallel T/L was simulated using EMTP software. To evaluate of the proposed algorithm, we used the several different cases 64 sampled data per cycle. The test results show that the proposed algorithm was minimized the error factor and speed of fault location estimation.

An Algorithm of fault Location Technique for Long Transmission Line (송전선로의 고장점 표정 알고리즘)

  • Park, C.W.;Kim, S.R.;Shin, M.C.;Nam, S.B.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF