• Title/Summary/Keyword: Negative Impedance

Search Result 161, Processing Time 0.021 seconds

Correlation and Comparison Between $Yin$-Deficiency Questionnaire Score and Biofunctional signals (음허와 생체신호의 상관성 및 비교 연구)

  • Yoo, Seung-Yeon;Lee, Jin-Moo;Park, Young-Jae;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.68-78
    • /
    • 2012
  • Objectives: The purpose of this study was to analyze the relationship between Yin-deficiency questionnaire score and various biofunctional signals in women. Methods: A retrospective chart review was performed on charts of 195 patients who visited Gangdong Kyung Hee Hospital between April 1st and September 30th, 2011. The subjects were categorized into two groups, a low Yin-deficiency group (n=118) and a high Yin-deficiency group (n=77). The authors analyzed the correlation between Yin-deficiency questionnaire score and biofunctional signals by Pearson's correlation coefficient test and the difference in biofunctional signals between the two groups by independent samples t-test using SPSS for windows. Results: 1. Negative correlations were observed between the temperature difference of back-humerus, standard deviation of all R-R intervals (SDNN), total power (TP), low frequency (LF), high frequency (HF) on heart rate variability parameters, and Yin-deficiency questionnaire score. A positive correlation was observed between the temperature difference of knee-humerus and Yin-deficiency questionnaire score. 2. The temperature difference of back-humerus in the high Yin-deficiency group was significantly higher than that in the low Yin-deficiency group. The temperature difference of knee-humerus, height, waist-hip ratio, SDNN, TP, LF, and HF of the high Yin-deficiency group were significantly lower than those of the low Yin-deficiency group. Conclusions: The results of this study suggest that the comprehensive diagnosis of Yin-deficiency and biofunctional signals is useful.

The Design of Low Noise Amplifier for Overall IMT-2000 Band Repeater (IMT-2000 중계기용 전대역 저잡음 증폭기 설계)

  • 유영길
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.409-412
    • /
    • 2002
  • The LNA(Low Noise Amplifier) is designed for use in low cost commercial application covered fully IMT-2000 band(1920~2170MHz, BW=250MHz). It is optimized source inductance for source lead and designed to equivalent etched line. The LNA uses a high pass impedance matching network for noise match and simple structure. The bias circuit designs have been made self-biased with a negative voltage applied to gate. The power supply voltage is 8V, total current is 180mA. The LNA is biased at a Vgs of -0.4, Vds of 4V for first stage and Vds of 5V for second stage. The LNA is designed competitively for commercial product specification. The measured gain and noise figure of the completed amplifier was 20dB and 1dB, respectively. Also, input VSWR, P1dB and gain flatness was measured of 1.14 ~ l.3dB, 22.4dBm and $\pm$0.45dB, respectively. The designed LNA can be used for commercial product.

Preparation of Co3O4/NF Anode for Lithium-ion Batteries

  • Tian, Shiyi;Li, Botao;Zhang, Bochao;Wang, Yang;Yang, Xu;Ye, Han;Xia, Zhijie;Zheng, Guoxu
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.384-391
    • /
    • 2020
  • Due to its characteristics of light weight, high energy density, good safety, long service life, no memory effect, and environmental friendliness, lithium-ion batteries (LIBs) are widely used in various portable electronic products. The capacity and performance of LIBs largely depend on the performance of electrode materials. Therefore, the development of better positive and negative materials is the focus of current research. The application of metal organic framework materials (MOFs) derivatives in energy storage has attracted much attention and research. Using MOFs as precursors, porous metal oxides and porous carbon materials with controllable structure can be obtained. In this paper, rod-shaped Co-MOF-74 was grown on Ni Foam (NF) by hydrothermal method, and then Co-MOF-74/NF precursor was heat-treated to obtain rodshaped Co3O4/NF. Ni Foam was skeleton structured, which effectively relieved. The change of internal stress changes and destroys the structural volume of the electrode material and reduces the capacity attenuation. Co3O4/NF composite material has a specific discharge capacity of up to 1858 mA h/g for the first time, and a reversible capacity of up to 902.4 mA h/g at a current density of 200 mA/g, and has excellent rate and impedance performance. The synthesis strategy reported in this article opens the way to design high-performance electrodes for energy storage and electrochemical catalysis.

Design of Hair-Pin Band-Pass Filter Using New Equivalent Circuit of Tapped-Line (탭 선로의 새로운 등가 회로를 이용한 헤어핀 대역 통과 필터 설계)

  • Yun, Tae-Soon;Kwoun, Sung-Su;Hong, Tae-Ui;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1150-1155
    • /
    • 2006
  • In this paper, the equivalent circuit of tapped-line that is applied in the band-pass filter is suggested and the value of an equivalent circuit is mathematically defined. An equivalent circuit of tapped-line is composed by open stub and transmission line that has negative electrical length, and the position of tapped-line and the value of resonator's length can be obtained by the impedance of resonator and the inverter. The new design method using equivalent circuit leads to very good agreement compared with theoretical value. The hair-pin band-pass filter using equivalent circuit of tapped-line shows the insertion loss of 1.1 dB and the return loss of 20 dB at the center frequency of 2 GHz.

The Correlational Study of Health Promotion Lifestyle and Body Composition in a University Students (일개 대학생의 건강증진 생활양식과 신체조성간의 관계 연구)

  • Park, Yeon-Suk;Lee, Hye-Gyeong
    • Journal of the Korean Society of School Health
    • /
    • v.19 no.1
    • /
    • pp.67-78
    • /
    • 2006
  • Purporse : The purpose of this study was to examine the relationship between a health promoting lifestyle and body composition in university students. The study subjects were 194 university students who attended K-university located in Chungnam. Methods : The data was collected between March 2 and May 31, 2004. The instrument used for this study was the modified Health Promoting Lifestyle Profile(HPLP) developed by Walker, Sechrist, & Pender(1987). The body composition was measured by In Body 3.0, a Bioelectrical Impedance Analyzer. The data was analyzed using the SPSS/WIN 10.0 program by t-test, ANOVA and pearson correlation coefficients. Results : The results of this study are as follows: 1) The scores of the Health Promoting Lifestyle(HPL) ranged from 79 to 170, with a mean score of 110(±15.8). The mean scores of sub-categorical HPL were self-actualization 31.8(±4.9), health responsibility 17.0(±4.0), exercise 8.3(±3.2), nutrition 15.4(±3.7), interpersonal relationships 20.3(±3.5) and stress management 17.2(±3.4). 2) The HPL according to the subjects' general characteristics had significant correlation to exercise amount(F=8.09, p<.01), drinking amount(F=6.56, p<.01), perceived health status(F=19.2, p<.01) and perceived health knowledge (F=15.9, p<.01). 3) The total HPL did not significantly correlate with any categories in body composition. The exercise area of sub-categorical HPL had significant positive correlation to height (r=.199, p<.01), weight(r=.181, p<.05) and soft lean mass(r=.257, p<.01), and negative correlation to percent body fat(r=-.255, p<.01) in body composition. Conclusion : The results suggest that the exercise area of sub-categorical HPL was an important variable for an exercise program's development such as nursing intervention for the health promotion of university students.

Hygroscopic Characteristics of $TiO_{2-x}$ Thin Film Humidity Sensors by RF Magnetron Sputtering (고주파 마그네트론 스퍼터링에 의한 $TiO_{2-x}$ 박막 습도센서의 습도감지특성)

  • Lee, Sung-Pil;Yoon, Yeu-Kyung
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.83-89
    • /
    • 1998
  • $TiO_{2-x}$ thin film humidity sensors have been fabricated by sputtering method and their physical and hygroscopic characteristics have been investigated. The sputtering conditions and sintering conditions affect the sensor's sensitivity toward humidity. AES and SEM micrographs were taken for the analysis of crystal structures, surface morphology caused by adsorbed water vapour. $TiO_{2-x}$ humidity sensors showed negative impedance-humidity characteristics and the sensor which was fabricated by experimental condition 2(rf power of 200W) showed higher sensitivity and linearity than others. Then the slope of the sensor was about $0.794\;K{\Omega}/%RH$ and the response time of $TiO_{2-x}$ humidity sensors was about 2 min. for adsorption and about 3 min. for desorption at the operating temperature of $30^{\circ}C$.

  • PDF

Electrochemical Characteristics of Hybrid Capacitor using Core-shell Structure of MCMB/Li4Ti5O12 Composite (Core-shell 구조의 MCMB/Li4Ti5O12 합성물을 사용한 하이브리드 커패시터의 전기화학적 특성)

  • Ko, Hyoung Shin;Choi, Jeong Eun;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.52-57
    • /
    • 2014
  • The MCMB-$Li_4Ti_5O_{12}$ with core-shell structure was prepared by sol-gel process to improve low cycle capability of MCMB in this study. The electrochemical characteristics were investigated for hybrid capacitor using MCMB-$Li_4Ti_5O_{12}$ as the negative electrode and $LiMn_2O_4$, Active carbon fiber as the positive electrode. The electrochemical behaviors of hybrid capacitor using organic electrolytes ($LiPF_6$, EC/DMC/EMC) were characterized by charge/discharge, cyclic voltammetry, cycle and impedance tests. The hybrid capacitor using MCMB-$Li_4Ti_5O_{12}/LiMn_2O_4$ electrodes had better capacitance than MCMB hybrid systems and was able to deliver a specific energy with 67 Wh/kg at a specific power of 781 W/kg.

Body Composition, Food Intake and Clinical Blood Indices of Female College Students (일부 여대생의 체성분, 식이 섭취실태 및 혈액 임상조사)

  • 김정희;안혜준;이상은
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.6
    • /
    • pp.977-985
    • /
    • 2003
  • This study was done to evaluate the health and nutritional status of female college students in Seoul. The subjects were 63 healthy college students aged 20 to 29 years. Their body composition, dietary intakes, clinical blood indices were investigated. Their body composition was determined by means of a multifreqency bioelectrical impedance analysis. Their dietary intake was determined using 3-day record method and their nutrient intake was analyzed by Computer Aided Nutritional analysis program for professional (CAN-pro). Their hemoglobin, hematocrit, red blood cell (RBC), white blood cell (WBC) and mean corpuscular volume (MCV) were determined by semi-automated microcell counter (F-520). Their plasma total cholesterol, TG, and HDL-cholesterol levels were measured using test kits. All data were statistically analyzed by SAS PC package program. Their average consumption of calcium, iron vitamin A, vitamin B2 and niacin were 63.3%, 65.0%, 85.2%, 89.2% and 95.2% of RDA, respectively. The overall mean values of the hematological indices in the female college students were within the normal range. However anemic subjects with hemoglobin (< 12 g/dl) and hematocrit (<36%) accounted for about 20% of the subjects. The mean levels of total cholesterol, HDL-cholesterol and TG were 188.4mg/dl, 69.9mg/dl and 67.4mg/dl, respectively. The percentages of the subjects with plasma total cholesterol level (> 200mg/dl) and LDL-cholesterol (>130mg/dl) were about 41% and 30.4%, respectively. The data showed a significantly positive correlation between either body fat (%) or BMI and TG. However. there was a significantly negative correlation between either body fat (%) or BMI and HDL-cholesterol. These overall results suggest that it is necessary for college women to be educated regarding consuming more iron and vitamin C and less fat, in order to prevent iron deficiency anemia and/or cardiovascular diseases in later life.

Improvement of Rate Capability and Low-temperature Performances of Graphite Negative Electrode by Surface Treatment with Copper Phthalocyanine (구리 프탈로시아닌으로 표면처리된 흑연 음극의 속도특성 및 저온성능 개선)

  • Jurng, Sunhyung;Park, Sangjin;Ryu, Ji Heon;Oh, Seung M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.3
    • /
    • pp.130-135
    • /
    • 2015
  • The rate capability and low-temperature characteristics of graphite electrode are investigated after surface treatment with copper phthalocyanine (CuPc) or phthalocyanine (Pc). Uniform coating layers comprising amorphous carbon or copper are generated after the treatment. The rate performance of graphite electrodes is enhanced by the surface treatment, which is more prominent with CuPc. The resistance of the graphite electrode estimated from electrochemical impedance spectroscopy and pulse resistance measurement is the smallest for the CuPc-treated graphite. It is likely that the amorphous carbon layer formed by the decomposition of Pc facilitates $Li^+$ diffusion and the metallic copper derived from CuPc improves the electrical conductivity of the graphite electrode.

A Non-Linear Characteristics Modeling of High Frequency FL Lamp by Experimental Values (실험식을 이용한 고주파 형광램프의 비선형특성 모델링)

  • 함중걸;백수현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.51-55
    • /
    • 1997
  • The high frequency fluorescnet lighting systems are widely used because of their high luminous efficacy. However, the performance of the fluorescnet lamp at high frequency reveals significant changes depending upon operating frequency, lamp shape, lamp voltage and current while adapting either an electronic or an magnetic ballast. Therefore the matching between the fluorescent lamp and the ballast is the major concern in designing a lighting system. In this paper, high frequency characteristics of the FHF32W lamp is measured in a range of frequencies from 12kHz to 50kHz. And we presented a model of a fluorescnet lamp with non-linear impedance depending on the lamp current. Finally, after identifying the operating condition under negative imped¬ance behavior as lamp current changing, we proposed a method of choosing the optimal parameter of a high frequency fluorescnet lamp and the result is analyzed.

  • PDF