• Title/Summary/Keyword: Needle imaging

Search Result 141, Processing Time 0.029 seconds

Pine Needle Aspiration Cytology of a Thymic Carcinoid Tumor - A Case Report - (가슴샘 카르시노이드종양의 세침흡인 세포소견 - 1예 보고 -)

  • Oh, Young-Ha;Jang, Ki-Seok;Song, Young-Soo;Lee, Chul-Burm;Park, Choong-Ki;Park, Moon-Hyang;Park, Yong-Wook
    • The Korean Journal of Cytopathology
    • /
    • v.16 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Carcinoid tumors of the thymus are vanishingly rare, and the characteristic cytologic findings of this condition have never before been reported in Korea. Recently, we encountered a 58-year-old woman who had been suffering from general weakness and weight loss for several months. Radiological imaging revealed a large anterior mediastinal mass. A fine needle aspiration biopsy (FNAB) of the mass showed predominantly scattered single cells, as well as some loose clusters of small cells with scanty cytoplasm. Some of these small cells exhibited plasmacytoid features, with moderately granular cytoplasm. We also discuss the cytological differential diagnosis between thymic carcinoid and other mediastinal tumors.

Preliminary Report of Three-Dimensional Reconstructive Intraoperative C-Arm in Percutaneous Vertebroplasty

  • Shin, Jae-Hyuk;Jeong, Je-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.2
    • /
    • pp.120-123
    • /
    • 2012
  • Objective : Percutaneous vertebroplasty (PVP) is usually carried out under three-dimensional (2D) fluoroscopic guidance. However, operative complications or bone cement distribution might be difficult to assess on the basis of only 2D radiographic projection images. We evaluated the feasibility of performing an intraoperative and postoperative examination in patients undergoing PVP by using three-dimensional (3D) reconstructive C-arm. Methods : Standard PVP procedures were performed on 14 consecutive patients by using a Siremobil Iso-$C^{3D}$ and a multidetector computed tomography machine. Post-processing of acquired volumetric datasets included multiplanar reconstruction (MPR) and surface shaded display (SSD). We analyzed intraoperative and immediate postoperative evaluation of the needle trajectory and bone cement distribution. Results : The male : female ratio was 2 : 12; mean age of patients, 70 (range, 77-54) years; and mean T score, -3.4. The mean operation time was 52.14 min, but the time required to perform and post-process the rotational acquisitions was 7.76 min. The detection of bone cement distribution and leakage after PVP by using MPR and SSD was possible in all patients. However, detection of the safe trajectory for needle insertion was not possible. Conclusion : 3D rotational image acquisition can enable intra- or post-procedural assessment of vertebroplasty procedures for the detection of bone cement distribution and leakage. However, it is difficult to assess the safe trajectory for needle insertion.

Inadvertent Dural Puncture during Caudal Approach by the Introducer Needle for Epidural Adhesiolysis Caused by Anatomical Variation

  • Kim, Si Gon;Yang, Jong Yeun;Kim, Do Wan;Lee, Yeon Ju
    • The Korean Journal of Pain
    • /
    • v.26 no.2
    • /
    • pp.203-206
    • /
    • 2013
  • There have been reports of abnormalities in the lumbosacral region involving a lower-than-normal termination of the dural sac, which is caused by disease or anatomical variation. Inadvertent dural puncture or other unexpected complications can occur during caudal epidural block or adhesiolysis in patients with these variations, but only a small number of case reports have described this issue. We report a case of dural puncture by the introducer needle before attempting caudal epidural adhesiolysis, which occurred even though the needle was not advanced upward after penetrating the sacrococcygeal ligament. Dural puncture was caused by a morphological abnormality in the lumbosacral region, with no pathological condition; the dural sac terminal was located more distally than normal. However, dural puncture could have been prevented if we had checked for such an abnormality in the magnetic resonance imaging (MRI) taken before the procedure.

Diagnostic Imaging for Solitary Nodular Form of Alimentary Lymphoma in a Dog (개 고립 결절 형태의 소화기계 림프종에 대한 진단영상 1례)

  • Choi, Ji-Hye;Kim, Hyun-Wook;Jang, Jae-Young;Kim, Hye-Jin;Kim, Jun-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.467-472
    • /
    • 2007
  • Alimentary lymphoma accounts for approximately 5% of neoplasm and diffuse lesion is more common than solitary nodular form in dogs. An eleven year-old male Yorkshire terrier was examined because of nonspecific gastrointestinal symptoms such as anorexia and vomiting for 10 days. An abdominal mass was palpated, which was originated from small intestinal wall in abdominal ultrasonography. Small intestine was obstructed by hypoechoic mass and lost normal layering and measured 24.5m. After fine-needle aspiration, septic peritonitis due to intestinal rupture occurred and emergency surgery was performed. Solitary mass was found in small intestine and diagnosed as alimentary lymphoma through histopathologic examination. Conclusively, abdominal ultrasonouaphy could verify the thickened bowel, loss of wall layering and decrease of motility and percutaneous ultrasound-guided fine-needle aspiration is considered as useful diagnostic technique, especially in nodular form of alimentary lymphoma.

Development of a Lightweight Prediction Model of Fuel Injection Rates from High Pressure Fuel Injectors (고압 인젝터의 분사율 예측을 위한 경량 모델 개발)

  • Lee, Sanggwon;Bae, Gyuhan;Atac, Omer Faruk;Moon, Seoksu;Kang, Jinsuk
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.188-195
    • /
    • 2020
  • To meet stringent emission regulations of automotive engines, fuel injection control techniques have advanced based on reliable and fast computing prediction models. This study aims to develop a reliable lightweight prediction model of fuel injection rates using a small number of input parameters and based on simple fluid dynamic theories. The prediction model uses the geometry of the injector nozzle, needle motion data, injection conditions and the fuel properties. A commercial diesel injector and US No. 2 diesel were used as the test injector and fuel, respectively. The needle motion data were measured using X-ray phase-contrast imaging technique under various fuel injection pressures and injection pulse durations. The actual injector rate profiles were measured using an injection rate meter for the validation of the model prediction results. In the case of long injection durations with the steady-state operation, the model prediction results showed over 99 % consistency with the measurement results. However, in the case of short injection cases with the transient operation, the prediction model overestimated the injection rate that needs to be further improved.

Diagnostic imaging and treatment of hepatic abscess in a Dachshund (개에서 발생한 간 농양의 진단 영상과 치료 증례)

  • Jung, Joohyun;Chae, Woongjoo;Chang, Jinhwa;Oh, Sunkyoung;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.119-124
    • /
    • 2008
  • A castrated male, 4-year old, Dachshund weighing 5.3 kg with an acute history of anorexia, vomiting, severe depression, and hypothermia for 1 day was referred. Severe leukopenia, mild increased hepatic enzymes, and mild imbalanced electrolyte were found on laboratory tests. There are no remarkable findings on abdominal radiographs. Ultrasonography showed multifocal heterogeneous and hypoechoic round regions in the liver. Ultrasound guided fine needle aspiration and drainage were performed and hepatic abscess was diagnosed. The patient was recovered normally without any complications through aggressive medical treatments from the result of culture and sensitivity test.

Computerized Tomography-guided Percutaneous Radiofrequency Thermocoagulation of Stellate Ganglion -A case report- (전산화 단층촬영 투시하 성상 신경절의 경피적 고주파 열 응고술 -증례 보고-)

  • Chung, Jun-Seok;Choi, Rak-Min
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.128-131
    • /
    • 1999
  • Stellate ganglion block is a well established method for the management of certain pain syndromes (e.g., chronic regional pain syndrome, facial pain) in the cervicothoracic region and upper extremity. The stellate ganglion resides between the C7 transverse process and the head of the first rib. Anesthetic injections for the stellate ganglion block are typically made at the level of the transverse process of either the C6 or C7 vertebrae to avoid the pleura, vessels, and nerve roots. Method of positioning the needle tip directly at the ganglion has been described, but are problematic because of the risk of injury to or injection into adjacent structures. It is necessary to know the exact anatomic position of the stellate ganglion when permanent blockade is required by means of radiofrequency thermocoagulation. Whereas fluroscopy shows only bony feature, computerized tomography also images nerves, vessels, and lung, allowing accruate needle placement. We report a case of the percutaneous radiofrequency thermocoagulation of the stellate ganglion after computerized tomography-guided localization.

  • PDF

Chest Wall Lipogranuloma after Hydrogel Implant Rupture: Case Report

  • Park, So Yoon;Han, Boo-Kyung;Cho, Eun Yoon;Bang, Sa-Ik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.191-195
    • /
    • 2015
  • We present a 53-year-old woman with a large chest wall mass in the interpectoral space, which was eventually confirmed as a lipogranuloma resulting from hydrogel implant rupture. Ultrasonography (US) showed reduced implant volume with surrounding peri-implant fluid collection, suggesting the possibility of implant rupture. A heterogeneously hypoechoic mass was found between the pectoralis major and minor muscles adjacent to the ruptured implant. On magnetic resonance imaging (MRI), there was a large mass in the left interpectoral space of the upper inner chest wall. The mass showed slightly high signal intensity (SI) on pre-contrast T1-weighted image (WI) with mixed iso and high SI on T2-WI. The signal of the mass was suppressed using the water suppression technique but not with the fat suppression technique on T2-WI. The mass showed diffuse enhancement upon contrast enhancement. The enhancing kinetics showed persistent enhancement pattern. US-guided core needle biopsy revealed a lipogranuloma and removal confirmed a ruptured PIP hydrogel implant.

Evaluation of oral and maxillofacial swellings using ultrasonographic features

  • Abdelsalam, Tarek Abdallah;Amer, Maha Eshak;Mahrous, Ahmed;Abdelkader, Moustafa
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.201-208
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the characteristic features of oral and maxillofacial swellings that could be seen on ultrasonographic examinations. Materials and Methods: Fifty patients with oral and/or maxillofacial swellings were randomly selected, thorough case histories and clinical examinations were done, ultrasonographic examinations with Doppler imaging were performed, and the features of every group were studied. Finally, histopathological evaluations were performed to identify the final diagnosis, according to which patients were classified into 5 groups; group I: inflammatory/space infection and abscess swellings, group II: cystic swellings, group III: lymph node swellings, group IV: benign swellings, and group V: malignant neoplastic swellings. Results: A significant association (P<0.05), with a contingency coefficient of 0.88, was found between the histopathological and ultrasonographic diagnoses, with ultrasonography having a diagnostic accuracy of 89% in diagnosing maxillofacial swellings. The diagnostic accuracy of ultrasonography was 100% for lymph node and malignant swellings, followed by 98% for inflammatory and cystic swellings and 92% for benign swellings. The sensitivity of the ultrasonographic diagnosis was 100% for cystic, lymph node, and malignant swellings, followed by 91% for inflammatory swellings and 86% for benign swellings. Conclusion: Ultrasonographic features with Doppler imaging greatly aid in obtaining accurate diagnoses of oral and maxillofacial swellings. Ultrasonography is a recommended imaging tool for differentiating maxillofacial swellings and classifying them accurately.

Computed Tomographic and Magnetic Resonance Imaging Features of Oral Melanoma in a Dog

  • Arim Lee;Seokmin Lee;Hojung Choi;Youngwon Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.5
    • /
    • pp.370-374
    • /
    • 2023
  • Oral melanoma is the most common type of oral tumor in dogs. In this report, computed tomography (CT) and magnetic resonance imaging (MRI) were performed to diagnose a right oral pigmented mass in an 8-year-old dog. The oral mass appeared as a homogeneous soft tissue density parenchyma on pre-contrast CT images, and with heterogeneous enhancement on post-contrast images. Bone destruction of the right mandibular body around the mass and mild enlargement of the right mandibular lymph node were also found. On MRI, the bulky oral mass showed mixed hyperintensity and isointensity compared to the adjacent muscle, where irregular hyperintensity on T1-weighted images corresponded to hypointensity on the T2-weighted images. Based on the physical examinations and imaging results, melanoma was suspected and confirmed via fine-needle aspiration. These unique MRI signals were due to the high paramagnetic melanin content in the tumor, therefore MRI examination could be useful for diagnosis of melanoma.