Morphologic Analysis of Water-Cooled Bipolar Radiofrequency lesions on Egg White in Vitro

  • Kang, Sang-Soo;Park, Jung-Chan;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.151-154
    • /
    • 2012
  • Background: The aim of this study was to document the optimal spacing of two cannulae to form continuous strip lesions and maximal surface area by using water-cooled bipolar radiofrequency technology. Methods: Two water-cooled needle probes (15 cm length, 18-gauge probe with 6 mm electrode tip) were placed in a parallel position 10, 20, 24, 26, and 28 mm apart and submerged in egg white. Temperatures of the probes were raised from $35^{\circ}C$ to $90^{\circ}C$ and the progress of lesion formation was photographed every 1 minute with the increase of the tip temperature. Approximately 30 photographs were taken. The resultant surface areas of the lesions were measured with the digital image program. Results: Continuous strip lesions were formed when the cannulae were spaced 24 mm or less apart; monopolar lesions around each cannula resulted if they were spaced more than 26 mm apart. Maximal surface areas through the formation of continuous strip lesion were 221 $mm^2$, 375 $mm^2$, and 476 $mm^2$ in 10, 20, and 24 mm, respectively. Summations of maximal surface area of each monopolar lesions were 394 $mm^2$ and 103 $mm^2$ in 26 and 28 mm, respectively. Conclusions: Water-cooled bipolar Radiofrequency technology creates continuous "strip" lesions proportional in size to the distance between the probes till the distance between cannulae is 24 mm or less. Spacing the cannulae 24 mm apart and treating about $80^{\circ}C$ for 24 minutes maximizes the surface area of the lesion.

Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges (코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석)

  • Jo, Hyang-Eun;Jin, Chang-Hwan;Park, Dae-Won;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

Experimence Study of Trace Water and Oxygen Impact on SF6 Decomposition Characteristics Under Partial Discharge

  • Zeng, Fuping;Tang, Ju;Xie, Yanbin;Zhou, Qian;Zhang, Chaohai
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1786-1795
    • /
    • 2015
  • It is common practice to identify the insulation faults of GIS through monitor the contents of SF6 decomposed components. Partial discharges (PD) could lead to the decomposition of SF6 dielectric, so new reactions usually occur in the mixture of the newly decomposed components including traces of H2O and O2. The new reactions also cause the decomposed components to differ due to the different amounts of H2O and O2 even under the same strength of PD. Thus, the accuracy of assessing the insulation faults is definitely influenced when using the concentration and corresponding change of decomposed components. In the present research, a needle-plate electrode was employed to simulate the PD event of a metal protrusion insulation fault for two main characteristic components SO2F2 and SOF2, and to carry out influence analysis of trace H2O and O2 on the characteristic components. The research shows that trace H2O has the capability of catching an F atom, which inhibits low-sulfide SFx from recombining into high-sulfide SF6. Thus, the amount of SOF2 strongly correlates to the amount of trace H2O, whereas the amount of SO2F2 is weakly related to trace H2O. Furthermore, the dilution effect of trace O2 on SOF2 obviously exceeds that of SO2F2.

Stereotactic Neurotomy of the Ganglion Impar through the Sacrococcygeal Junction in Cancer-Related Perianal Pain -A case report- (회음부 암성 통증환자에서 시행한 천미골 접합부를 이용한 외톨이 교감 신경절의 정위적 신경절제술 -증례 보고-)

  • Kim, Keun Sook;Ko, Hyun Hak;Hwang, Sung Mi;Lim, So Young;Hong, Soon Yong;Shin, Keun Man
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.263-266
    • /
    • 2005
  • The ganglion impar is a solitary retroperitoneal structure at the caudal end of the paravertebral sympathetic chain. Block of this ganglion has been advocated as a means of managing intractable perineal pain. In 1990, Plancarte et al performed a neurolytic block of the ganglion impar using 4-6 ml of 10% phenol through the intergluteal skin over the anococcygeal ligament. However, technical difficulties are encountered with the placement of the needle while performing this technique, with complications from the injection of phenol also being a possibility. In 1995, a modified approach for blocking the ganglion impar through the sacrococcygeal ligament was introduced by Wemm and Saberski. We used a radiofrequency (RF) lesion generator to create a controlled and localized lesion with a lower incidence of neural damages compared to chemical neurolysis. RF thermocoagulation of the ganglion impar through the sacrococcygeal ligament was performed on a 70-year-old male patient with constant anal pain using a curved TEW electrode. The patient has been relieved of his pain, without serious complication. Therefore, this technique may be an easier and safer approach, which is associated with fewer chances of complications.

Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures (SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성)

  • Lee, Bok-Hee;Baek, Young-Hwan;Oh, Sung-Kyun;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.85-90
    • /
    • 2006
  • This paper presents experimental results relating to the preliminary breakdown characteristics in $SF_6/CO_2$ gas mixtures under a highly non-uniform electric field. The impulse pre-breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both the positive and negative polarities were fundamentally same. The first streamer corona was initiated at the tip of needle electrode, and the leaders developed with a stepwise propagation and bridged the test gap. The pause time of leader pulses in the positive polarity was significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity. The discharge channel path in the positive polarity was zigzag, and the leader channel in the negative polarity was thicker and brighter than that in the positive polarity.

A Basic Study on the Attachment Process of Lightning Leader to Ground (낙뢰 리더의 대지부착과정에 대한 기초적 연구)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

Effects of Propofol on Electroencephalogram in Dogs (Propofol이 개의 뇌파에 미치는 영향)

  • 장환수;장광호;채형규;권은주;김정은
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.359-367
    • /
    • 2000
  • The aim of this study was to evaluate the effects of propofol on cortical electroencephalogram (EEG) in seven dogs. Propofol infusion was accomplished from low concentration to high concentration in series, and each concentration was infused for 20 minutes (M0: 0, M0.5: 0.5, M1.0:1.0, and M1.5: 1.5 mg/kg/min of infusion rate). EEG was recorded via needle electrode placed at Cz, which was applied to International 10-20 system. Arterial blood pressure. blood gas analysis and ECG were also measured. Hoemodynamics, Pa$CO_2$, PaO$_2$, heart rate and respiratory rate were variable, but were net significant(p>0.05). The power spectra of EEG in every concentration was compared wish those of control (MO). The powers at a1l frequencies at M1.0 and Ml.5 were decreased. Especially, the powers of the frequencies over 20 Hz were significantly decreased (p<0.O5). Powers at frequencies between 8 and 15Hz at MO.S were significantly increased (p<0.05) in response to the painful stimuli. It was inferred that they may reflect activity of the brain which is consciously processing the external Stimuli. Like the Power spectra, al1 the band powers of He EEG ($\delta$ 1-4, $\theta$4-8, $\alpha$ 8-13, $\beta$L13-21. $\beta$H 21-30, \ulcorner 30-50, and total 1-5OHz) were decreased in proportion to the increase of infusion rate at M1 .0 and M1.5. Especially, decrease of $\beta$H and ${\gamma}$ were significant(p<0.01). At M0.5, $\alpha$ band was significantly increased(p<0.05) among all the bands. Seizure activities which were concide with occurrence of spike wave were shown in all dogs at Ml .0 and M1.5.

  • PDF

Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers (몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술)

  • Jung, Kwang-Seok;Park, Dae-Won;Cha, Hyeon-Kyu;Cha, Sang-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

Neurologic Study of SP6(Sanyinjiao, 三陰交) Acupuncture on Bladder parasympathetic Nerve, Tibial Nerve and Blood Pressure in Rats (삼음교(三陰交) 침자(鍼刺)가 부교감신경(副交感神經)의 방광분지(膀胱分枝), 경골신경(脛骨神經) 및 혈압(血壓)에 미치는 영향(影響))

  • Park, Chun-Ha;Yoon, Yeo-Choong;Na, Chang-Su
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.175-188
    • /
    • 2002
  • Objective : The effects of SP6(Sanyinjiao, 三陰交) acupuncture stimulation on bladder parasympathetic nerve activity (PNA), tibial nerve activity (TNA) as well as blood pressure were examined in anesthetized rats and the results are as follows. Methods : The parasympathetic nerve leading to the bladder was exposed retroperitoneally, and the tibial nerve in the hindlimb was exposed through inguinal area. PNA and TNA were recorded using a bipolar platinum-iridium wire electrode and it was connected to preamplifier. Blood pressure was measured using cannula that was inserted into femoral artery and was recorded with blood pressure sensor that is connected with transducer amplifier. The mean value of all parameters measured for 30 seconds before the stimulation was expressed as 100%. An acupuncture needle was inserted into the SP6 region to a depth of 4 mm. Results : Under intact state (IS), acupuncture stimulation for 120 seconds induced significant increase of PNA which was accompanied with decrease of blood pressure. At the same time, TNA showed temporary increase only with acupuncture stimulation. In 4 mg/kg of naloxone-administrated state (NAS), significant decrease of PNA was seen and it was accompanied with increase of blood pressure. TNA also showed temporary increase only with acupuncture stimulation under the NAS just like the IS. Conclusion : consider that SP6(Sanyinjiao, 三陰交) acupuncture stimulation activated parasympathetic nerve and caused vasodilation to lead into the diuresis, but naloxone reversed the effect of acupuncture for antidiuresis.