• 제목/요약/키워드: Needle detection

검색결과 93건 처리시간 0.027초

롤러 베어링의 진동특성을 이용한 자동변속기 결함 검출에 관한 연구 (A Study on the Fault Detection of Auto-transmission Using the Vibrational Characteristics of Roller Bearings)

  • 박기호;정상진;위혁;이국선;조성호
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.268-273
    • /
    • 2009
  • The roller bearings play an important role not only sustain radial or axial load of system, but carry out a rotatory movement as a various operating conditions. They happen that incipient faults which were caused by excessive load, manufacturing or assembling process's errors and many other reasons are created. The bearing faults make noise and vibration by a continuous collision of rotatory components, which can lower the quality and stability of auto-transmission. Therefore, it is important to detect the early fault as soon as possible. This paper presents a detecting method for the improvement in quality by developing the program which can be used to analyze and predict the vibrational characteristics caused by roller bearing faults. We completed development of the inspection system of vibration by applying the most efficient detecting methods and verified the system's reliability through experiments.

A Possible Application of the PD Detection Technique Using Electro-Optic Pockels Cell With Nonlinear Characteristic Analysis on the PD signals

  • Kang, Won-Jong;Lim, Yun-Sok;Chang, Young-Moo;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권2호
    • /
    • pp.6-11
    • /
    • 2001
  • Abstract- In this paper, a new Partial Discharge (PD) detection using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detecte by optical measuring system using Pockels cell, based on Mach-Zehner interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. In addition, the presence of chaos of the PD signals has been investigated by examining their means of qualitative and quantitative information. For the former, return map and 3-dimensional strange attractor have been drawn in order to investigate the presence of chaotic characteristics relevant to PD signals, detected through CT and Peckels sensor respectively, in the normalized time series. The presence of strange attractor indicates the existence of fractal structures in it's phase space. For the latter, several dimension values of strange attractor were verified sequentially. Throughout this paper, it is likely that the chaotic characteristics regarding the PD signals under air are verified.

포켈스 소자를 이용한 PD 신호의 검출 및 비선형적 해석에 관한 연구 (A possible application of the PD detection technique using electro-optic Pockels cell with nonlinear characteristic analysis on the PD signals)

  • 임윤석;강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1850-1852
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockels cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. A qualitative analysis was carried out by drawing Return map for the normalized time series of the detected PD signals. The results are as follows:(a) Fixed points, between 0.7 and 1.0, are appeared clearly in the right upper area of the return map as the increase in the number of obtained data.(b) Considerable periodicity have been remarked even though exact period and length can not be determined.(c) The self-similarity can be also observed inasmuch as the late paths do not follow the previous ones. Accordingly, exact quantitative analysis such as embedding dimension, fractal dimension, and Lyapunov exponents should be carried out for deducing the quantitative properties regarding PD phenomena.

  • PDF

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

미추 경막외차단 도중 발견된 천추 수막낭 -증례 보고- (Sacral Meningeal Cyst Detected during Caudal Epidural Block)

  • 강미숙;임영진;이상철
    • The Korean Journal of Pain
    • /
    • 제12권2호
    • /
    • pp.258-262
    • /
    • 1999
  • Sacral meningeal cyst is usually asymtomatic, but may be responsible for sciatic pain syndromes and other clinical symptoms. Sacral meningeal cyst might be suspected when definite explanation for the clinical symptom, such as herniation of the intervertebral disc or spinal stenosis is not found. Plain films and CT may suggest the presence of sacral meningeal cyst, but MR is the current imaging study of choice. Evaluation of the correlation between the symptom and the cyst is as important as detection of it. We have experienced a case of sacral meningeal cyst detected during caudal epidural block. The patient complained of low back pain radiating to thigh. Plain films and lumbar spine CT showed no remarkable finding except disc bulging. During caudal epidural needle insertion, there was leakage of clear CSF, and intrasacral cystic shadow was visualized by dye injection. MR confirmed sacral meningeal cyst.

  • PDF

부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단 (The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge)

  • 김성홍;박재준;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권3호
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

집단 검진에서 발견된 갑상선 우연암종에 대한 임상적 고찰 (Clinical Investigation of Incidentally Found Thyroid Carcinoma in Mass Screening)

  • 김은서;장항석
    • 대한기관식도과학회지
    • /
    • 제7권2호
    • /
    • pp.168-173
    • /
    • 2001
  • Background and Objectives: The introduction of highly sensitive imaging techniques has made it possible to detect many non-palpable nodules, or“incidentaloma”in the thyroid. Discovery of these lesions raises concerns about their malignancy, but the optimal strategy for managing these lesions has not been clearly established. This study was designed to evaluate the usefulness of ultrasonographic exam with new diagnostic criteria and presume the value of mass screening for thyroid cancer. Materials and Methods : Mass screening for thyroid cancer were carried out in conjunction with mass screening for breast cancer. The subjects were 630 women aged 30 years or over. Thyroid glands were examined with 10 MHz transducer ultrasonography by one radiologist. Needle aspiration biopsy were performed when suspicious of malignancy under the new diagnostic criteria. Results and Conclusion : The new ultrasonographic criteria to diagnose thyroid cancer provided useful information and ensured more accurate evaluation. 7 cases of thyroid cancer were discovered and successfully managed. It should be further demonstrated that there is sufficient value of mass screening for thyroid cancer to perform it independently despite early cancer detection.

  • PDF

방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단 (The Diagonosis of Treeing Breakdown Simultaneous Detection on Charge of Partial Discharge and Acoustic Emission Pulse)

  • 최재관;김성홍;박재준;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1781-1783
    • /
    • 1996
  • Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with a artificial needle shape void by the charge of partial discharge and acoustic emission pulse in each phase angle area at the same time. We have analyzed the ${\Phi}-Q-n$ pattern and the insulation diagnosis of the samples using statistic operators such as charge magnitude and A.E pulse factor, skweness, kurtosis, G,C. Therefore, the relation between the charge of partial discharge and A.E pulse will be helpful and efficient to predict the breakdown just before the breakdown occure.

  • PDF

유중 방전에 의한 초음파 측정용 광섬유 센서 특성 및 측정 데이터 분석 (Characteristics and Signal Analysis of Fiber-optic Sensor for Detecting Ultrasonic Waves Generated by Discharge in Insulation Oil)

  • 이상훈;송현직;이광식;김달우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.481-486
    • /
    • 2003
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

포켈스 효과를 이용한 불평등 전계 측정 (A possible application of the nonuniform electric field measurement using Pockets effect)

  • 강원종;임윤석;최재옥;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF