• Title/Summary/Keyword: Needle detection

Search Result 93, Processing Time 0.025 seconds

A New Possible Partial Discharge Detection Technique using Electro-optic Effect (전기광학 효과를 이용한 부분방전 신호의 검출)

  • Noh, S.S.;Chang, Y.M.;Lee, J.H.;Koo, J.Y.;Oh, C.H.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1929-1931
    • /
    • 1996
  • In this work, it is proposed new PD(partial discharge) detection technique using electro-optic effect, for which partial discharges generated from needle-plane electrode in air were detected through optical measuring system by use of $LiNbO3_3$ electro-optic crystal. As a result, it is noticed that PD measurable phase intervals are limited by the asymmetrical D-E hysteresis loop of the crystal with defects and half-wave voltage. However, both number of measured PD pulses and their amplitude were increased with applied voltage, which likely implies that it is possible to detect PD through newly proposed electro-optic method.

  • PDF

Ultrasonic-detection characteristics of optical-fiber sensor for insulation diagnosis (절연진단용 광섬유 센서의 초음파 검출특성)

  • Lee, S.H.;Sim, S.H.;Lee, K.S.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.183-186
    • /
    • 2002
  • It is well known that a discharge in oil is the source of various physical and chemical phenomena. One of them is ultra-sonic wave, and its detection is a useful method to the diagnosis of the transformer insulation condition. Conventionally, ultra-sonic waves are detected by Piezo-electric trans-ducer(PZT), and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test of the ultrasonic-detecting ability was performed for both of PZT and fiber-optic sensor. Discharge test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and showed time-delay characteristics. We analyzed the data with frequency domain and wavelet transform.

  • PDF

Thyroglobulin Measurement in Fine Needle Aspirates for Diagnosing Cervical Lymphnode Metastasis from Differentiated Thyroid Malignancy (갑상선암의 경부 림프절 전이 진단을 위한 미세침세척액 티로글로불린 측정법)

  • Ko, Hee-Young;Kim, Seung-Su;Lee, Chun-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.181-185
    • /
    • 2010
  • Purpose: Several studies report that detection of thyroglobulin (Tg) in fine-needle aspiration (FNA) biopsy washout fluid from lymph nodes identifies recurrences or metastases of differentiated papillary thyroid cancer (DPTC) in the neck with higher sensitivity and specificity than fine-needle aspiration cytology (FNAC). We evaluate the diagnostic efficacy and usefulness of Tg measurement in FNA washout fluid (FNA-Tg) and compare with FNAC. Materials and Methods: Forty-eight FNA samples of 37 patients who undergone ultrasonography to detect cervical lymph node metastasis of DPTC, were included for this study. Lymph node metastasis was confirmed by histopathologic examination or long-term imaging follow-up. Sensitivity, specificity and accuracy of FNA-Tg and FNAC were calculated. In 34 patients, we evaluated diagnostic accuracy of FNA-Tg according to the presence or absence of Tg antibody. Results: Sensitivity, specificity and accuracy of FNAC were 75.0%, 97.2% and 91.7%, respectively, and those of FNA-Tg were 100%, 88.9% and 91.7%, respectively. The presence of Tg antibody was not relevant to the diagnostic accuracy of FNA-Tg. Conclusion: FNA-Tg is a as accurate as FNAC with higher sensitivity. FNA-Tg and FNAC are complement techniques for diagnosing lymph node metastasis of DTPC.

  • PDF

Clinical Manifestations and Therapy of Tuberculous Cervical Lymphadenitis (경부 결핵성 림프절염의 임상양상과 치료)

  • 김상현;황동조;문준환;김정수
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.1
    • /
    • pp.7-13
    • /
    • 1999
  • Background and Objective: The tuberculous lymphadenitis of neck is one of the most common extra-pulmonary tuberculosis in Korea. Although the incidence of pulmonary tuberculo-sis has decreased recently, that of cervical tuberculous lymphadenitis has not decreased. In spite of great efforts and diversity of study, the exact criterias of diagnosis and optimal therapeutic methods of cervical tuberculous lymphadenitis have been the subject of much debate and still remain unclear. So we intend to enucleate clinical manifestations and suggest the optimal therapeutic manners. Material : The 483 cases, diagnosed as cervical tuberculous lymphadenitis by fine needle aspiration biopsy during the past 10 years from Jan. 1987 to Dec. 1996 Method : Retrospective study Results 1) The overall rate of tuberculous cervical lymphadenitis was 23.4% of neck mass. 2) Incidence ratio of male to female was 1:2.7 3) The frequent location of tuberculous lymphadenitis was posterior cervical area, supraclavicular area, jugular chain in order. 4) The response rate of medical treatment in tuberculous cervical lymphadenitis was 84.9%. 5) The duration of medical treatment in remissioned group was 18.6 months in average. 6) Surgical intervention was needed in 15.1%. 7) The duration of post operative medical treatment was 18.4 months in average. Conclusion : Tuberculous cervical lymphadenitis is prevalent in women, age of 20-40 years and mainly involve posterior cervical area. Fine needle aspiration biopsy is a very useful method for early detection of cervical tuberculous lymphadenitis. After diagnosis is made, anti-tuberculosis medication is recommended for more than 18 months. Unless the size of neck mass is decreases inspite of the thorough anti-tuberculosis medication for more than 1 month or if complication like as abscess or fistula occurs, surgery is needed with post operative medical treatment for more than 12 months.

  • PDF

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage (전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정)

  • Kim, Jeong-Tae;Kim, Nam-Jun;Lee, Jeon-Seon;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

A Study on the Fault Detection of Roller Bearings in the Auto-Transmission (자동변속기에서의 롤러 베어링 결함 검출에 관한 연구)

  • Park, Ki-Ho;Jung, Sang-Jin;Wee, Hyuk;Lee, Gook-Sun;Cho, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.84-88
    • /
    • 2008
  • The roller bearings play an important role not only sustain radial or axial load of system, but carry out a rotatory movement as a various operating conditions. They happen that incipient faults which were caused by excessive load, manufacturing or assembling process's errors and many other reasons are created. The bearing faults make noise and vibration by a continuous collision of rotatory components, which can lower the quality and stability of auto-transmission. Therefore, it is important to detect the early fault as soon as possible. This paper presents a detecting method for the improvement in quality by developing the program which can be used to analyze and predict the vibrational characteristics caused by roller bearing faults. We completed development of the inspection system of vibration by appling the most efficient detecting methods and verified the system's reliability through experiments.

  • PDF