• Title/Summary/Keyword: Needle Points

Search Result 125, Processing Time 0.023 seconds

Effect of NEES on the Occurrence of c-Fos in the Cerebrum of a Rat With Transient Global Ischemia (일과성 전뇌허혈 유발 쥐의 침전극 저주파자극 후 대뇌의 c-Fos 발현에 미치는 영향)

  • Lee, Jung-Sook;Kim, Sung-Won
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.69-76
    • /
    • 2010
  • Ischemia that causes stroke induces inflammation of brain cells and apoptosis and as a result, it influences much on the functional part of a man. The needle electrode electrical stimulation (NEES) that combines acupuncture of oriental medicine with electric therapy of western medicine relieves inflammation of cells and has effect on regrowth of nerve tissues. This study was conducted to verify the influence of NEES on the occurrence of c-Fos of cerebrum after applying NEES to the meridian point, Zusanli (ST 36) of a rats with induced ischemia. Global ischemia was induced by using ligation method on common carotid artery of male Sprague Dawley (SD) rats. The ligation was maintained for 5 minutes and then suture was removed for blood reperfusion. After inducing global ischemia, NEES was done to the left and right meridian points of Joksamri of a rat for 30 minutes after 12 hours, 24 hours, and 48 hours. The findings were as follows. 1. In the result of immunohistochemical method, the number of c-Fos immune response cells significantly decreased (P<.05) in NEES group than the control group (GI) that did not get NEES. 2. In the result of western blotting, the occurrence of c-Fos after 24 hours from the inducement of ischemia significantly decreased (P<.05) in NEES group than the control group (GI) that did not get NEES. Therefore, as the effect of NEES was shown highest after 24 hours from the ischemia, it is suspected that NEES would take important role in early treatment after cerebral stroke.

Source Tracking of PCDD/Fs in Ambient Air Using Pine Needles (소나무 잎을 이용한 대기 중 다이옥신/퓨란 발생원 추정)

  • Chun, Man-Young;Kim, Jeong-Soo;Koh, Doh-Yun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.49-60
    • /
    • 2015
  • Objectives: Pine needles were used as a passive air sampler (PAS) of atmospheric persistent organic pollutants (POPs). This study was performed to investigate concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) deposited on pine needles near a waste incinerator and PCDD/Fs source contributions using principal component analysis (PCA). Methods: Two-year-old pine needles were sampled at 11 points with respect to distance and wind direction from the incinerator. PCDD/Fs deposited on pine needles were analyzed with HRGC/HRMS. The source contribution of PCA was calculated with SPSS. Results: The average concentration of PCDD/Fs deposited on pine needle was 0.79 (0.27-1.76) pg TEQ/g dry, PCDDs with 0.24 (0.01-0.95) pg TEQ/g dry and PCDFs with 0.56 (0.27-0.82) pg TEQ/g dry, respectively. The average concentration fraction of PCDDs was 29.7%, that of PCDFs was 70.3%, and PCDFs were more prevalent than PCDDs. The contributions of PCDD/Fs sources were estimated as incineration at 58.3% and automobiles at 28.4%. However, a relation and regulation between PCDD/Fs concentrations deposited on pine needles and distance from incinerator or wind direction was not shown. Conclusion: It was concluded that atmospheric PCDD/Fs concentrations near an industrial complex with a waste incinerator were affected by multiple sources. However, PCDD/Fs concentrations were lower than in other inland cities with the exception of background area.

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

The Effect that the Application of Time-Based Electrolysis Has on Acute Ischemia

  • Lee, Jung Sook;Song, Young Wha;Kim, Sung Won
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.6 no.2
    • /
    • pp.846-851
    • /
    • 2015
  • This neurological damage accelerates the infection reaction of cells and apoptosis at the time of reperfusion after ischemia occurs. BCL-2/BCL-2 allogeneic begeminum has a function of suppressing the apoptosis of cells, and thus it is inferred that the susceptibility of cells to apoptosis is determined by the amount of allogeneic begeminum present which is determined based on the amount of BAX. Ischemia was induced in SD mice by occluding the common carotid artery for 5 minutes, after which blood was re-perfused. NEES was applied to acupuncture points, at 12, 24, and 48 hours post-ischemia on the joksamri, Hapgok. Protein expression was investigated through BAX antibody immuno-reactive cells in the cerebral nerve cells and Western blotting. The results were as follows: In the present study as well, as a result of observation of the change in the number of the BAX reaction cells after the inducement of GI, there was the aspect of most of the BAX reaction cells being observed in the corpus striatum area of the GI group 24 hours after the inducement of ischemia. This revealed the same results as those of previous studies in which the change in the number of BAX reaction cells occurred in all areas while ischemia was in progress. The change in the expression of BAX protein after 24 hours showed that there was a very significant reduction in the NEES group compared to the GI group (p<.01). As a result, a greatest amount of change in the number of BAX immunoreactive cells related to apoptosis 24 hours after ischemia appeared in the NEES group. This study that ischemia increases the expression of BAX that induces apoptosis. Thus, it is determined that ischemia is the main cause of the apoptosis of neurons, and this study reveals that low frequency needle electrode electrical stimulation has the effect of blocking the apoptosis of neurons by reducing protein related to the apoptosis of cells that has increased after ischemia has occurred.

A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA (침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성)

  • Lee, Jae-Pil;Lee, Chung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

Aspiration Cytology of Pilomatrixoma - Report of 2 Cases Misdiagnosed as Metastatic Carcinoma - (모기질 세포종의 흡인 세포학 - 전이성 암종으로 오진된 2예 보고 -)

  • Koh, Jae-Soo;Ha, Chang-Won;Cho, Kyung-Ja;Jang, Ja-June
    • The Korean Journal of Cytopathology
    • /
    • v.4 no.1
    • /
    • pp.25-29
    • /
    • 1993
  • We describe cytologic findings of two cases of pilomatrixoma which had been cytologically misdiagnosed as suspicious malignant and malignant lesions in 35 year-old and 22 year-old females who presented a palpable neck mass. The cytologic smears showed many basaloid cells with a high nuclear-cytoplasmic ratio, nuclear hyperchromatism and prominent nucleoli, keratinized squamous cells with pyknotic nuclei, foreign body giant cells, and chronic inflammatory cells in necrotic back-ground. Retrospective view of this aspiration smear revealed that these findings were characteristic features of pilomatrixoma, and the evenly distributed chromatin pattern as well as the lack of nuclear pleomorphism were considered to be the differential points from malignant neoplasm. Pilomatrixoma is a benign neoplasm which should be included in differential diagnosis if the fine needle aspiration cytologic smear of a neck mass or subcutaneous mass of any site showed these features.

  • PDF

UB-IOT Modeling for Pattern Analysis of the Real-Time Biological Data (실시간 생체 데이터의 패턴분석을 위한 UB-IOT 모델링)

  • Shin, Yoon Hwan;Shin, Ye Ho;Park, Hyun Woo;Ryu, Keun Ho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.2
    • /
    • pp.95-106
    • /
    • 2016
  • Biometric data may appear different depending on the person and sasang Medicine has a close relationship with the Department. Biometric data not only mean a human heart rate, a blood pressure, a heart rate, and the past medical history, degree of aging, body mass index, but also is used as a reference measure for determining the state of health of the person. So biometric data should be reproduced for the application purposes, depending on their applications. In previous studies, because the biometric data is changed in real time and applies only to snap shut at the time of the continuity of the current time is excluded. Therefore, in this study in order to solve this problem, we propose a biometric data patton analysis model comprising a continuity of time in the big data environment consisting of biometric data. The proposed model can help determine the choice of needle position carefully when using the electronic acupuncture for care and health promotion.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

A Systematic Review of Randomized Controlled Trials on Acupuncture Treatment for Neck Pain (경항통에 침치료를 시행한 무작위대조군연구(RCT)들에 대한 계통적 연구)

  • Kim, Hyun-Wook;Kim, Sung-Soo;Kang, Jung-Ah;Nam, Dong-Woo;Kim, Eun-Jung;Hong, Kwon-Eui;Kim, Sung-Chul;Lee, Jae-Dong;Kim, Kap-Sung;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.103-123
    • /
    • 2009
  • Objectives : The aim of this study is to review RCTs of acupuncture treatment for neck pain and to establish standards of acupuncture treatment for neck pain. Methods : We searched articles in Pubmed using ICD 10. Study quality was assessed using the FEAS and Jadad score. Results and Conclusions : Three review studies and nineteen clinical trials were searched and reviewed. Among the nineteen clinical trials reviewed, positive outcome was reported in thirteen studies. Most frequently used meridians were GB, BL, SI, GV and LI, The most frequently used acupuncture points were $GB_{20}$, $GB_{21}$, $LI_4$, $BL_{10}$, $GV_{14}$ and $SI_3$. More than two needles were inserted in the studies and needle retention time was more than 10 minutes. The most frequently used needle length was 40mm, and diameter was 0.25mm and 0.30mm. The mean number of treatment sessions were more than 10 times. Frequency of treatment was more than once a week, And treatment duration was more! than 5 weeks. The total FEAS scores ranged from 3 to 15.5, and the mean value was 9.39. Jadad score ranged from 2 to 5, and the mean value was 3.42. The number of studies scoring over three points on the Jadad scale was sixteen.

  • PDF

Review of Randomized Controlled Trials on Ideal Acupuncture Treatment for Degenerative Knee Osteoarthtritis (RCT논문을 중심으로 한 퇴행성 슬관절염 침구 치료 방법에 대한 고찰)

  • Kim, Eun-Jung;Lee, Seung-Deok;Jung, Chan-Yung;Yoon, Eun-Hye;Jang, Min-Gee;Nam, Dong-Woo;Kim, Hyun-Wook;Lee, Eun-Yong;Kim, Kyung-Ho;Lee, Geon-Mok;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.125-145
    • /
    • 2009
  • Objectives : To analyze the inclusion criteria of participants, control group interventions, and the results of prior studies of acupuncture for OA. Also to identify aspects of the procedure that are associated with positive outcomes in order to establish ideal acupuncture treatment model. And to assess the methodological quality of the trials with modified Jadad score and FEAS in order to evaluate the quality of prior studies and find out whether or not acupuncture has a positive effect in treating OA. Methods : Articles up to the date of November 2008 were searched via computerized databases of PubMed, Journal of Korean Oriental Medicine, The Journal of Korean Acupuncture & Moxibustion Society and Journal of Oriental Rehabilitation Medicine. Bibliographies of reviewed papers were also searched and reviewed. Only randomized controlled trials (RCTs) and systematic reviews concerning the effects of acupuncture or electroacupuncture (EA) on symptoms of osteoarthritis of the human knee, published in English and Korean were included. The acupuncture treatment methods of the reviewed trials were assessed based on STRICTA. And the methodological quality of the trials was assessed by modified Jadad score and FEAS. Results : Twenty one trials of acupuncture for OA were analyzed. Based on the results of this review the following factors might contribute to optimal results from acupuncture treatment. 1) Usage of $ST_{35}$, $GB_{34$, $EX_{32}$, $ST_{36}$ and $SP_9$ acupuncture points. 2) More than four acupuncture points should be used. 3) More than 15 minutes of needle retention time. 4) Needle length-40mm and diameter-0.30mm 5) Usage of EA 6) more than 10 times treatment 7) Treatment frequency of more than once a week, 8) Treatment duration longer than 6 to 8 weeks. Conclusions : High quality clinical trials of Acupuncture for OA is still in lack. Future investigators must concentrate their attentions on the quality of acupuncture treatment itself used in the trials as well as the methodological quality of trials.

  • PDF