Anti-apoptotic and neuroprotective effects of acupuncture techniques of tonification or sedation at HT9${\cdot}$LR1, HT3${\cdot}$KI10 on focal brain ischemic injury induced by intraluminal filament insertion in rats (심정격(心正格) 혈위(穴位)(소충(少衝)${\cdot}$대돈(大敦), 소해(少海)${\cdot}$음곡(陰谷))에 대한 영수(迎隨) 및 염전(捻轉) 보사(補瀉) 침자(鍼刺)가 국소 뇌허혈 유발 흰쥐의 항뇌세포고사와 신경보호 효과에 미치는 영향)

  • Byun, Jeong-Yun;Youn, Dae-Hwan;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.25 no.1
    • /
    • pp.229-246
    • /
    • 2008
  • Objectives : Acupoints of LR1(Dadun)${\cdot}$HT9(Shaochong), KI10(Yingu)${\cdot}$HT3(Shaohai) are used as controlling the diseases from heart problems. Especially, when they are used, tonification or sedation techniques method is taken as a controlling the medication for an early stroke in the Korean medicine. So the aim of this study is to investigate the anti-apoptotic and neuroprotective effects of Acupuncture techniques of tonification or sedation at LR1${\cdot}$HT9, KI10${\cdot}$HT3 on the focal ischemia induced by intraluminal filament insertion in rats. Materials and Methods : The focal ischemia was induced by intraluminal filament insertion into middle cerebral artery. The animals were divided into five groups (n=7 in each group) : Control group, no therapy group after ischemia induced; AT-1; acupuncture therapy group at LR1${\cdot}$HT9, KI10${\cdot}$HT3 after ischemia-induced. AT-2; acupuncture therapy at right LR1, HT9(forward direction), KI10${\cdot}$HT3(opposite direction) inserting to the direction of route of the each meridian. AT3; acupuncture therapy at right LR1, HT9(twirling forward with the thumb of right hand 9 times), KI10${\cdot}$HT3(twirling forward with the forefinger of right hand 6 times) AT-4; acupuncture therapy at right LR1, HT9(forward direction, twirling forward with the thumb of right hand 9 times), KI10${\cdot}$HT3(opposite direction, twirling forward with the forefinger of right hand 6 times) inserting to the direction of route of the each meridian. The anti-apoptotic and neuroprotective effects of Acupuncture techniques of tonification or sedation at LR1, HT9, KI10${\cdot}$HT3 were observed by Bax, Bcl-2, mGluR5, Cytochrome c, Cresyl violet and ChAT-stain. Results : The intensity of Bax and Bax/Bcl-2 ratio were increased in ACU-2 and ACU-4 group but decreased in ACU-3 group. The intensity of mGluR5 was increased in ACU-1, ACU-2, ACU-3 and ACU-4 group. The intensity of cytochrome c was decreased in ACU-3 and ACU-4 group. The density of neurons stained by Cresyl violet and ChAT were increased in ACU-1, ACU-3 and ACU-4 group. Conclusions : Our study suggests that acupuncture therapy of tonification at LR1, HT9 by twirling forward with the thumb of right hand 9times, sedation at KI10${\cdot}$HT3 by twirling forward with the forefinger of right hand 6 times after perpendicularly inserting needle shows anti-apoptotic and neuroprotective effects on cholinergic neuron in focal cerebral ischemia of the stroke in rats.

  • PDF

The evaluation of image-guided catheter drainage in pleural effusion and empyema (흉수 및 농흉에서의 영상유도하 도관배액술의 유용성 평가)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.403-409
    • /
    • 1996
  • Background : Pleural fluid collections may pose a difficult therapeutic problem. Complete drainage of complicated effusions or empyemas and reexpansion of atelectatic lung are important in obtaining a satisfactory clinical outcome. The usual approach to the diagnosis and treatment of patients with pleural effusion and empyema has been with needle thoracentesis and chest tube drainage. With chest tube drainage, technical difficulties and failures may occur as a result of improper tube drainage, particularly when there is a loculation or multiple and inaccesible collections. Fluoroscopic or sonographic guidance facilitates the proper tube insertion and drainage. Method : Twenty eight patients were required for tube drainage due to pleural fluid collections between January 1994 to February 1996. The author compared the results of drainage under applying each different method between blind chest tube insertion and image guided catheter insertion. Results : The conventional blind chest tube group comprised 14 patients; 6 empyema, 6 tuberculous effusion, and 2 parapneumonic effusion. The image guided catheter group of smaller french were composed of 14 patients; 2 empyema, 6 tuberculous effusion, 5 parapneumonic effusion, and 1 effusion of undetermined origin. Radiologic improvement with successful drainage was noticed in 79% with the blind chest tube group, whereas in 93% with the image guided catheter group. The complication with the latter method was unremarkable. Conclusion : Image guided catheter drainage was safe and highly successful in treating patients, not only with complicated effusion also with loculated empyema. Image guided catheter drainage offers an alternative in patients in whom closed drainage is required as the initial treatment.

  • PDF

Incidence of Paresthesia Related to the Insertion Length of Catheter during the Epidural Catheterization (경막외강 카테터 삽입 시 삽입 길이와 감각이상의 빈도)

  • Lim, Jun Goo;Kim, Young Jae;Cho, Jae Heung;Lee, Sang Eun;Kim, Young Hwan;Lim, Se Hoon;Lee, Jeong Han;Lee, Kun Moo;Cheong, Soon Ho;Choi, Young Kyun;Shin, Chee Mahn
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.50-53
    • /
    • 2007
  • Background: Continuous epidural catheterization is a popular and effective procedure for postoperative analgesia. However, continuous epidural catheterization has associated complications such as venous puncture, dural puncture, subarachnoid cannulation, suboptimal catheter placement, and paresthesia because the tip of the epidural catheter touches thenerves of the dura in the epidural space. In this study, we compared the incidence of paresthesia in two different lengths of epidural catheter insertion. Methods: One hundred women undergoing gynecologic or orthopedic surgery were enrolled in this prospective, double-blinded, randomized study. All patients were randomly divided into two groups based on the insertion length of the epidural catheter 2 cm (group A) or 4 cm (group B). A Tuohy needle was inserted in the lumbarspinal region with a bevel directed cephalad by use of the median approach, and then the epidural space was confirmed by the loss of resistance technique with air. While the practitioner inserted an epidural catheter into the epidural space, a blind observer checked for paresthesia or withdrawal movement. Results: In 97 included patients, 30.6% of the patients in group A (n = 49) had paresthesia, versus 31.3% in group B (n = 48). Withdrawal movements were represented in 2% and 6% of the patients in group A and group B, respectively. There was no difference in the incidence of paresthesia and withdrawal movement between the two groups. Conclusions: There is no clear relationship for the incidence of catheter-related paresthesia according to the catheter length inserted into the epidural space for epidural analgesia.

Using Ultrasonography in Korean Medicine to Observe Organs and Diseases, and Evidence of its Use (한의학에서 초음파 진단기기를 활용한 장부 및 질병 관찰과 그 활용 근거)

  • Baik, Tai-Hyeun
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.70-92
    • /
    • 2014
  • Objectives: Due to advance of science and IT technology, high tech imaging equipment like ultrasonography, CT, MRI and PET scan is constantly being developed and progressed; use of these techniques is needed for Korean medicine. Methods: Historical study was undertaken on the evidence of using ultrasonography. Normal organs and various sorts of diseases were also observed by ultrasonography. Results: Korean medicine judges disease of internal organs and condition of health by symptoms of functional disease and organic disease based on anatomical theory. Ultrasonography based on anatomical theory is non-invasive and free from radiation exposure and can be performed directly from clinical practice in real-time. Ultrasonography can be a big help for securing the stability of the internal organs in inserting needles in the thorax and abdomen as well as diagnosing functional and organic diseases based on anatomical theory. Conclusion: We look forward to a great development of scientification and objectification of Korean medicine by using and researching imaging equipment based on anatomical theory as well as ultrasonography.

Endoscopic Ultrasound Staging of Upper Gastrointestinal Malignancies

  • Saadany, Sherif El;Mayah, Wael;Kalla, Ferial El;Atta, Tawfik
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2361-2367
    • /
    • 2016
  • Since 1980, endoscopic ultrasound (EUS) has been used as an important tool for the evaluation of malignant diseases in hollow viscus and bilio-pancreas, as well as sub-epithelial tumors. The high-resolution capacity and low penetration depth of EUS make it possible to obtain highly detailed images of the gastrointestinal wall and immediate surroundings to a depth of 4-5 cm. Thus, over the past 35 years, EUS succeeded to modify management in significant number of cases and is now considered a gold standard tool for many gastrointestinal diseases, especially in the pancreatico-biliary tract, and adjuvant needle insertion now allows access to remote lesions that were difficult to reach in the past. With the growing spectrum of indications, tissue sampling for diagnostic purposes has become common. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in staging of upper gastrointestinal malignancies, especially esophageal, gastric and ampullary tumors.

Reaction and Characterization of Silylene and its Precusor (Silylene과 Silylene 전구체의 반응 특성 연구)

  • Kong, Young Kun;Ahn, Young Man
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.321-327
    • /
    • 1994
  • The mild thermal decomposition of 7, 7-dimethyl-1, 2, 3, 4, 5-pentaphenyl-7-silanorbornadiene with excess methyl alcohol proceeds to give 1-methoxydimethylsilyl-1, 2, 3, 4, 6-pentaphenylcyclohexa-2, 5-diene which is colorless needle crystal. The cophotolysis of the solution of 7-silanorbornadiene in the excess ethyl alcohol proceeds with loss of silylenes to give ethoxydimethylsilane which is insertion reaction product of silylene with O-H bond of ethyl alcohol. According to above results, it is presumed that the mechanism of photochemical decomposition and that of mild thermochemical decomposition of 7-silanorbornadiene are different.

  • PDF

Studies on Electroacupuncture Anesthesia of Experimental Animal (실험동물의 전침마취에 관한 연구)

  • 이성호;이성옥;권건오;김인봉;김덕환;조성환;김무강;김명철;유명조
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.417-421
    • /
    • 1999
  • To establish the electroacupuncture anesthesia for experimental animal, 5 adult rabbits (Newzealand-white species) and 6 rats (Spraque-dawley) were examined. The acupoints used for electroacupuncture anesthesia were Tian-ping and Bai-hui. After perpendicular insertion of needle to the acupoints, positive electrode was connected at Tian-ping and negative electrode was connected at Bai-hui using veterinary electroacupuncture anesthesia apparatus, respectively. Electric conditions were 2~3 V and 30 Hz in rabbits, and 1.5~2 V and 30 Hz in rats, respectively. To examine the effect of electroacupuncture anesthesia, laparotomy (2 heads), castration (2 heads) and ovariohysterectomy (1 head) were applied in rabbits, and laparotomy (5 heads) and castration (1 head) were peformed in rats, respectively. The induction time of electroacupuncture anesthesia was very rapid and approximately 1 minute, and pain of body surface including the extremities was not detected in rabbits and rats. As for the reactions with electroacupuncture anesthesia, consciousness was vivid, blepharoreaction was not observed and the tail was up at early stage but was down afterwards in rabbits. The same findings except cotinuous lifting of the tail were observed in rats. The pain was not observed during incision and suture, bleeding was comparatively small volume and the class of anesthesia effect was excellent.

  • PDF

Assessment of the Quality of Case Reports in the Journal of Acupuncture Research Using the CARE and STRICTA Guidelines

  • Nam, Eun-Young;Hwang, Ji Hye
    • Journal of Acupuncture Research
    • /
    • v.37 no.4
    • /
    • pp.224-232
    • /
    • 2020
  • The purpose of this study was to assess the quality of the case reports in the Journal of Acupuncture Research (JAR). All case reports were retrieved from November 2017 to June 2020. There were 19 case reports included in this assessment based on the case report (CARE) guidelines and case report and standards for reporting interventions in clinical trials of acupuncture (STRICTA) guidelines. The overall quality of reporting was relatively high (83.08% on Case Report guidelines and 77.78% on Standards for Reporting Interventions in Clinical Trials of Acupuncture guidelines), but several crucial items remained substantially underreported, such as identifying as a case report (keywords), patient information and perspective, clinical findings, diagnostic assessment, and intervention information. In 18 out of 19 included case reports of acupuncture-related interventions, several items remained considerably underreported such as acupuncture regimen variation, depth of needle insertion, response sought, and experience of acupuncturists. In the classification by disease, condition, or syndrome, 13 out of 19 included case reports were for musculoskeletal disorders (68.4%), which is the main clinical medical field of Korean medicine services. The results of this study may help develop more appropriate reporting guidelines for case reports published in JAR.

A Case Report of Injection Laryngoplasty Who have Difficulty in Neck Extension Using, an I-Gel Laryngeal Mask Airway (경부 신전이 불가한 성대 마비 환자에서 I-Gel$^{TM}$ 후두마스크를 이용한 전신 마취하 성대주입술 증례)

  • Jo, Kwang-Hee;Jung, Chan-Min;Jang, Chul-Ho;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.25 no.2
    • /
    • pp.96-98
    • /
    • 2014
  • Injection laryngoplasty is simple and useful procedure in patient with vocal cord paralysis even under local anesthesia. For approaching vocal cord level, flexibility of neck mobility is required to operate injection laryngoplasty but it is relatively difficult to approach vocal cord in patient who has cervical fixations. Laryngeal mask airway (LMA) can be helpful:We use a LMA (I-gel$^{TM}$) during intubation without neck extension on flat supine position under general anesthesia and have a good operation filed. LMA with swivel connector give surgeons better surgical vision and make insertion of fibroscope easily during operation. Hyaluronic acid injection was done use needle (25 G, 5 cm) via percutaneous cricothyroid space : This procedure can be useful method for patients who suffer from not only weak voice but also dysphagia and aspiration high vagal palsy patient after spine surgery or uncooperative with awake injection laryngoplasty.

  • PDF

Reliable design and electrical characteristics of vertical MEMS probe tip (수직형 MEMS 프로브 팁의 신뢰성 설계 및 전기적 특성평가)

  • Lee, Seung-Hun;Chu, Sung-Il;Kim, Jin-Hyuk;Han, Dong-Chul;Moon, Sung
    • Journal of Applied Reliability
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • Probe card is a test component which is to classify the known good die with electrical contact before the packaging in the ATE (automatic testing equipment). Conventional probe tip was mostly needle type, it has been difficult to meet with conventional type, because of decreasing chip size, pad to pad pitch and pads size increasingly. For that reason, probe cards using MEMS (micro electro mechanical system) technology have been developed for various semiconductor chips. In this paper, Area Array type MEMS Probe tip was designed,, fabricated, and characterized its mechanical and electrical properties. The authors found that good electrical characteristics under $1{\Omega}$ were acquired with gold (Au) and aluminium (Al) pad contact test over 0.5gf and 4gf respectively. And, contact resistance variation under $0.1{\Omega}$ were achieved with 100,000 times of repetition test. And, insertion loss (IS) for high frequency operation was ascertained over 300MHz at -3dB loss.

  • PDF