• Title/Summary/Keyword: Needle Fracture

검색결과 38건 처리시간 0.028초

치과용 Ni-Ti합금의 표면특성에 미치는 Mo함량의 영향 (Effects of Mo Content on Surface Characteristics of Dental Ni-Ti Alloys)

  • 최한철;김재운;박순균
    • Corrosion Science and Technology
    • /
    • 제22권1호
    • /
    • pp.64-72
    • /
    • 2023
  • Ni-Ti shape memory alloy for dental nerve treatment devices was prepared by adding Mo to Ni-Ti alloy to improve flexibility and fatigue fracture characteristics and simultaneously increase corrosion resistance. Surface properties of the alloy were evaluated. Microstructure analysis of the Ni-Ti-xMo alloy revealed that the amount of needle-like structure increased with increasing Mo content. The shape of the precipitate showed a pattern in which a long needle-like structure gradually disappeared and changed into a small spherical shape. As a result of XRD analysis of the Ni-Ti-xMo alloy, R-phase structure appeared as Mo was added. R-phase and B2 structure were mainly observed. As a result of DSC analysis, phase transformation of the Ti-Ni-Mo alloy showed a two-step phase change of B2-R-B19' transformation with two exothermic peaks and one endothermic peak. As Mo content increased, R-phase formation temperature gradually decreased. As a result of measuring surface hardness of the Ti-Ni-Mo alloy, change in hardness value due to the phase change tended to decrease with increasing Mo content. As a result of the corrosion test, the corrosion potential and pitting potential increased while the current density tended to decrease with increasing Mo content.

A method of bedside urethrography before catheterization in pelvic trauma in Korea: a case report

  • Hojun Lee;Sung Yub Jeong;Kun Hwang
    • Journal of Trauma and Injury
    • /
    • 제36권4호
    • /
    • pp.451-453
    • /
    • 2023
  • We introduce a convenient method of urethrography before catheterization for patients with pelvic trauma that can be used in a resuscitation area. A 10-mL syringe without a needle was used. X-ray contrast medium (Iohexol, 300 mg I/mL) was administered through the urethral orifice using a 10-mL syringe without needle and a simple pelvic anteroposterior film was taken (70 kilovolt [peak], 50 mAs). A 36-year-old soldier with a saddle injury from a gun barrel was taken to a trauma center. He had a pelvic fracture and complained of hematuria. Bedside urethrography above described was performed. The anterior urethra showed nonspecific findings, but dye leaked from the posterior urethra. Bedside Foley catheter insertion was attempted, but the catheter could not be advanced past the membranous urethra. Thereafter, suprapubic catheterization was performed. On the day of the injury, iliac artery embolization was carried out. The dislocated sacroiliac joint was also treated using open reduction and internal fixation. On hospital day 7, guidewire Foley insertion was performed. This bedside urethrography technique is simple and useful for pelvic fractures in which urethral injury is suspected.

늑골 골절 후 발생한 늑간 신경병증의 임상적 연구 (A Clinical Study of Intercostal Neuropathy after Rib Fracture)

  • 강정훈;이석기;서민범;나정엽;장재혁;김권영
    • Journal of Chest Surgery
    • /
    • 제43권1호
    • /
    • pp.53-57
    • /
    • 2010
  • 배경: 이 연구는 늑골 수상 후 발생하는 늑간 신경병증에 대한 평가를 위하여 숫자통증등급, 통증 기간 및 체질량 지수에 따른 늑간 신경병증에 대한 심한 정도를 알고자 하였다. 대상 및 방법: 늑골 골절 수상 후 3개월 이상 동안 보존적인 치료에도 불구하고 심한 통증을 호소하는 환자 47명을 대상으로 근전도 검사를 시행하여 흉부의 늑간 및 척추 주위 근육에 대한 평가를 하였다. 결과: 47명 중에서 11명에 대하여 늑간 신경병증의 진단을 얻을 수 있었으며, 남자 8명과 여자 3명이었으며, 그 연령은 직업적으로 활동적인 연령대였다. 늑간 신경병증이 호발하는 부위는 7번부터 12번 부위 늑골 골절의 늑간이었다. 그 빈도는 단일 골절보다는 다발성 골절과 밀접한 상관 관계를 알 수 있었다. 그 증상으로는 흉통(90.9%), 감각이상(81.8%), 무감각(63.6%), 후부 흉통(27.2%), 그리고 근위축(18.2%) 순이었다. 근전도에 의한 숫자통증등급, 통증 기간 및 체질량 지수와 관계는 없었다. 결론: 늑골 골절수상 후 3개월 이상 지속적인 통증을 호소하는 환자에서 지속적인 늑간 신경통에 대한 진단을 위한 평가로 근전도가 도움이 될 수 있다.

원발성 흉골결핵의 외과적 치험 -1례 보고- (Primary Sternal Tuberculosis with Spontaneous Fracture Treated by Resection and Reconstruction -A Case Report-)

  • 배상일;김미혜;오태윤;장운하
    • Journal of Chest Surgery
    • /
    • 제31권2호
    • /
    • pp.190-193
    • /
    • 1998
  • 본 강북삼성병원 흉부외과에서는 병적골절이 동반된 원발성 흉골결핵을 치험 하였다. 22세된 여자환자가 특별한 외상이없이 발생한 흉골부위의 통증 및 골절로 입원 하였다. 입원당시 시행한 흉부단순촬영 및 전산화단층촬영상 흉골의 괴사소견과 연부조직의 부종이 관찰되었다. 세침세포검사상 냉농양을 동반한 결핵성 골수염으로 진단되어 술전 항결핵 치료후 수술을 시행하였다. 수술시 흉골중앙부위의 골괴사 및 다발성 누공을 확인하였으며, 골괴사 부위를 제거한후 환자의 장골능을 골이식 하였다. 병리조직학적 결과는 결핵성 골수염의 소견 및 치즈양괴사를 보였다. 술후 경과는 양호 하였으며, 2개월동안의 추적검사상 흉골의 불안정은 관찰되지 않았다.

  • PDF

Thermo-splint를 이용한 불안정한 관골궁골절에 대한 효과적인 고정방법 (The Effective Reduction Method of Unstable Zygomatic Arch Fracture with Thermo-Splint)

  • 김순흠;이수향;최현곤;신동혁;엄기일;송우철
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.110-115
    • /
    • 2008
  • Purpose: The objective of this study is to propose an effective management of unstable zygomatic arch fracture. The reduction methods of arch fracture were relatively simple but the maintenance of reduction state is very troublesome. On this, authors introduce an effective management method of unstable zygomatic arch fracture. Methods: Authors experienced 23 cases of unstable segmental zygomatic arch fractures and used Thermo-splint in all cases. All the arch fractures were reduced through Gillies' approach under the general anesthesia. After the reduction, the most effective suspension points were marked on the covering skin of the fractured arch. A needle of heavy nonabsorbable suture material was inserted toward the marking site under the reduced zygomatic arch. And then Therm-splint was dipped in the hot water, and we got the splint pattern of patient face. Reshaped Thermo-splint was trimmed and fixated with previous suspension suture materials. More additive suspension was done if necessary. The splint was applied for in two to three weeks postoperatively. Results: In all the cases, good cosmetic and functional results were observed without severe complications. There were 4 cases of incomplete reductions but they also had no specific problems. There were no facial nerve symptom and scar(stitch mark). Postoperative slight tenderness and trismus were completely subsided after removal of the splint. Conclusion: The Thermo-splint safely protect and maintain the postoperative reduction state. The application, maintenance and removal were easy and simple. It could be reformed to any contour of face and had enough rigidity for supporting. Above all these things, effective prevention of displacement and easy manipulation were significant merit. Authors experienced good results with Thermo-splint, and would introduce it for another method of management of zygomatic arch fracture.

골절에 침 치료를 적용한 2013년 이후 증례보고 문헌고찰 (A Review of Case Reports on the Application of Acupuncture as a Treatment for Fracture since 2013)

  • 백승원;남경호;최승관;이정한;한윤희
    • 한방재활의학과학회지
    • /
    • 제31권4호
    • /
    • pp.49-63
    • /
    • 2021
  • Objectives This study aimed to investigate the trend in treating fracture with acupuncture and to evaluate the quality of case reports. Methods All case reports of fractures treated with acupuncture were extracted from four Korean web databases. We classified these studies by five fracture sites and investigated frequently used meridian and acupoint, outcome measurements, treatment period. And we assessed the quality of the case reports by the STandards for Reporting Interventions in Clinical Trials of Acupuncture (STRICTA) guidelines. Results A total of 33 case reports were included. The outcome measurements were divided into six categories, and the outcome measurements used in more than three studies showed improvement in patient symptoms. The mainly used meridians for each fracture site were as follows: chest and abdomen (GB, LR, CV), back (BL, GB), upper limb (LI, TE), lower Limb (GB, ST, BL, SP). The most commonly used acupoints for each fracture site were as follows: chest and abdomen (Ashi points, GB24, GB25, GB26, LR13, LR14, CV16, CV17, CV18, CV19), back (BL23, BL24, BL25, BL26, BL40, BL51, BL52, BL60, GB34), upper limb (LI4, LI10, LI11, TE3), lower limb (GB34, GB40). According to the STRICTA guidelines, more than 54.54% of the reports were found to be 'not reported' or 'not sufficient' in the following categories: 'response sought', 'description of participating acupuncturist', and 'number of needle insertions per subject per session'. Conclusions The meridians and acupuncture points frequently used for acupuncture treatment of fractures were near the fracture site. Future clinical studies involving acupuncture must be reported in accordance with the STRICTA guidelines to improve transparency and uniformity.

Isolated pulmonary cryptococcosis in an immunocompetent boy

  • Bauer, Siegfried;Kim, Ji-Eun;La, Kyong-Suk;Yoo, Young;Lee, Kee-Hyoung;Park, Sang-Hee;Choung, Ji-Tae;Kim, Chul-Whan
    • Clinical and Experimental Pediatrics
    • /
    • 제53권11호
    • /
    • pp.971-974
    • /
    • 2010
  • Pulmonary cryptococcosis is rare in immunocompetent subjects. Here, we present the case of a 16-year-old boy who was referred to our pediatric department for the management of multiple consolidations detected on chest radiography, which was routinely performed when the patient was being evaluated for an ankle fracture. Fine needle aspiration biopsy was performed, and the definitive diagnosis was established as cryptococcal pneumonia. After 8 weeks of antifungal treatment, the pulmonary nodules on the chest radiographs disappeared.

내열강의 내부품질에 따른 절삭가공 특성에 관한 연구 (A Study on the Machining Characteristics by the Internal Quality of Heat Resisting Steel)

  • 채왕석
    • 한국생산제조학회지
    • /
    • 제9권1호
    • /
    • pp.24-29
    • /
    • 2000
  • This paper is experimental study of machining characteristics about martensitic heat resisting steel STR11. Machining characteristics are different according to internal quality(chemical compositions, microscopic structure and nonmetallic inclusion) mechanical properties(tensile strength value impact value and hardness) and dynamic cutting force. Following are the results : 1. In analyzing internal quality test materials have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness are larger. But values of elongation and impact values are smaller. Fracture surface of tensile specimen is ductile. 3, Cutting force is decreasing with cutting speed increasing 4. Cutting force is increasing with feed speed increasing.

  • PDF

마르텐사이트계 내열강의 금속 및 기계적 특성에 관한 연구 (A Study on the Internal Quality and the Machining Characteristics of Martensitic Heat Resisting Steel)

  • 채왕석;권용기;김동현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1997
  • In this paper, we have studied internal quality including chemical compositions, microscopic structure and nonmetalic inclusion of test materials. We have analyzed machining characteristics including tensile strength value, impact value, hardness value etcs. Test materials are usd martensitic heat resisting steel, STR11 and STS420J2. The obtined results are as follows : 1. In analyzing internal quality, STR11 and STR420J2 have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness value are large STR11 than STS420J2. But elongation impact are smaller STR11 than STS420J2. 3. Fracture surface of tensile speciman is ductile in STR11 and STS420J2.

  • PDF

The effects of Mg2Si(p) on microstructure and mechanical properties of AA332 composite

  • Zainon, Fizam;Ahmad, Khairel Rafezi;Daud, Ruslizam
    • Advances in materials Research
    • /
    • 제5권1호
    • /
    • pp.55-66
    • /
    • 2016
  • This paper describes a study on the effects of $Mg_2Si_{(p)}$ addition on the microstructure, porosity, and mechanical properties namely hardness and tensile properties of AA332 composite. Each composite respectively contains 5, 10, 15, and 20 wt% reinforcement particles developed by a stir-casting. The molten composite was stirred at 600 rpm and melted at $900^{\circ}C{\pm}5^{\circ}C$. The $Mg_2Si$ particles were wrapped in an aluminum foil to keep them from burning when melting. The findings revealed that the microstructure of $Mg_2Si_{(p)}/AA332$ consists of ${\alpha}$-Al, binary eutectic ($Al+Mg_2Si$), $Mg_2Si$ particles, and intermetallic compound. The intermetallic compound was identified as Fe-rich and Cu-rich, formed as polygonal or blocky, Chinese script, needle-like, and polyhendrons or "skeleton like". The porosity of $Mg_2Si_{(p)}/AA332$ composite increased from 8-10% and the density decreased from 9-12% from as-cast. Mechanical properties such as hardness increased for over 42% from as-cast and the highest UTS, elongation, and maximum Q.I were achieved in the sample of 10% $Mg_2Si$. The study concludes that combined with AA332, the amount of 10 wt% of$Mg_2Si$ is a suitable reinforcement quantity with the combination ofAA332.