• Title/Summary/Keyword: Neck angle

Search Result 400, Processing Time 0.025 seconds

The Coordinative Locomotor Training Intervention Strategy Using the ICF Tool to Improve the Standing Posture in Scoliosis: A Case Report

  • Lee, Jeong-a;Kim, Jin-cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • Purpose: This study was examined to improve the standing posture of a scoliosis client using the ICF Tool. Methods: For examination, the study subject was a 16-year-old female student diagnosed with 3curve-pelvic (3CP) type scoliosis. Information about her were collected through a client interview and based on international Classification of Functioning, Disability and Health (ICF). The ICF core set was for post-acute musculoskeletal conditions, and the ICF level 2 items suggested by National Rehabilitation Information Center (NARIC) were added to the recommendations for scoliosis. For evaluation, the ICF assessment sheet was used to identify the interaction among the problems. For the diagnosis, the client's functional problems were described in ICF terms. For the prognosis, the global goals for reaching the client's functional activity and participation level were presented as the long-and short-term goals. For the intervention, a coordinative locomotor training program composed of warm-up, main exercise, and cool-down was applied 3 times a week, 50 minutes a day, for 5 weeks. For the outcome, the differences between before and after the intervention were compared with the ICF qualifier and are shown with the ICF evaluation display. Results: Clinical advantages were observed in body function and structure (7° decrease of thoracic angle, 7 score increase of trunk muscle power, 6.47s improve of one leg standing, 4 score decrease of neck pain). The activity for maintaining the standing posture, in which the client had a primary limitation, was improved. Conclusion: Applying the coordinative locomotor training program is expected to improve scoliosis client's standing posture.

Pattern of microimplant displacement during maxillary skeletal expander treatment: A cone-beam computed tomography study

  • Ney Paredes;Ausama Gargoum;Ramon Dominguez-Mompell;Ozge Colak;Joseph Bui;Tam Duong;Maya Giannetti;Fernanda Silva;Kendra Brooks;Won Moon
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.289-297
    • /
    • 2023
  • Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years) were treated successfully with the MSE II appliance. Their pre- and post-expansion CBCT data were superimposed. The pre- and post-expansion anterior and posterior inter-MI angles, neck and apical inter-MI distance, plate angle, palatal bone thickness at the MI positions, and suture opening at the MI positions were measured and compared. Results: The jackscrew plate was slightly bent in both anterior and posterior areas. There was no significant difference in the extent of suture opening between the anterior and posterior MIs (P > 0.05). The posterior MI to hemiplate line was greater than that anteriorly (P < 0.05). The apical distance between the posterior MIs was greater than that anteriorly (P < 0.05). The palatal thickness at the anterior MIs was significantly greater than that posteriorly (P > 0.01). Conclusions: In the coronal plane, the angulation between the anterior MIs in relation to the jackscrew plate was greater than that between the posterior MIs owing to the differential palatal bone thickness.

Posture Correction Guidance System using Arduino (아두이노를 활용한 자세교정 유도 시스템)

  • Kim, Donghyun;Kim, Jeongmin;Bae, Woojin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.369-372
    • /
    • 2021
  • These days, people spend more time sitting at a desk for studies or work. Also, because people continue to use computers, smartphones, and tablet PCs often during break times, their posture is getting worse. Maintaining a position of bad posture for an extended period of time causes problems with the musculoskeletal system related to the neck, shoulders, and spine. Additionally, problems such as physical fatigue and posture deformation are predicted to expand to a wide range of age groups. Therefore, the core function of the system we are developing is to ensure correct sitting posture and to receive alert notifications via the created mobile application. To create the system, a flex sensor, pressure sensor, and tilt sensor are attached to a chair and utilized. The flex sensor detects and compares the amount of bending in the chair's posture and transmits this value to an Arduino Uno R3 board. Additionally, information such as body balance and incline angle are collected to determine whether or not the current sitting posture is correct. When the posture is incorrect, a notification is sent through the mobile application to indicate to the user and the monitoring app that their posture is not correct. The system proposed in this study is expected to be of great help in future posture-related research.

  • PDF

A Patient with Spinal Accessory Neuropathy after Self Neck Massage Treated with TMJ Balancing Therapy: A Case Report (경부 자가 마사지 후 척수부신경병증을 호소하는 환자의 턱관절균형요법 치험례)

  • Hakwon Kim;Jung Eun Choi;Sang Soo Park;Wang Jung Hur;Horyong Yoo;Miso S. Park
    • Journal of TMJ Balancing Medicine
    • /
    • v.13 no.sup
    • /
    • pp.27-33
    • /
    • 2023
  • The purpose of this study is to describe the effects of temporomandibular joint balancing therapy on a patient with a spinal accessory neuropathy. A patient reported sternocleidomastoid muscle and trapezius muscle weakness after self-massage. The patient was instructed to wear the Accurate Balancing Appliance (ABA) for at least 8 hours per day and maintain an upright posture. The patient received cervical spine manipulation on day 2, 4, and 6. The patient's progress was tracked based on the angle at which the head turned to the right from the midline when she lifted her head while lying down, as well as the muscle strength and pain in the right trapezius muscle. The patient recovered spontaneously after 7 days. The ABA and cervical spine manipulation assisted the patient in reducing fatigue and discomfort during daily activities.

  • PDF

Comparison Study of Different Approach (Deltoid Splitting Approach and Delto-pectoral Interval Approach) for Proximal Humeral Fractures (근위 상완골 골절의 수술적 치료에서 삼각근 분할 도달법과 삼각 대흉간 도달법의 임상적, 방사선학적 추시 결과 비교)

  • Kim, Seung-Hee;Dan, Jinmyoung;Kim, Byoung-Kook;Lee, Yun-Seok;Kim, Hyoeng-Jung;Ryu, Keun-Jeong;Lee, Jin-Hyun;Kim, Jae-Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2013
  • Purpose: A comparison of the radiographic and the clinical outcomes between two different surgical approaches-Deltoid splitting and Delto-pectoral interval-on the proximal humerus fractures treated by locking compressive plate (LCP), is done. Materials and Methods: Medical records and pre- and postoperative radiographs were reviewed retrospectively for 75 adult patients who underwent surgical fixations with locking compressive plates from May 2005 to December 2011. Patients were divided into two groups according to the surgical methods. Differences in the neck-shaft angle between immediate postoperative period and final follow-up were compared between the two groups. Differences in constant score and Korean shoulder score (KSS) between affected arms and contralateral arms at final follow-up were also compared. Results: The differences in the neck-shaft angle between immediate postoperative period and at final follow-up was 12.04 degrees on average in Deltoid splitting approach and 10.20 degrees in Delto-pectoral interval approach, which was not statistically significant. Differences in constant score/KSS between the affected arm and the contralateral arm were 13.78/22.74 points in deltoid-splitting approach on average and 19.41/31.13 points in Delto-pectoral interval approach, showing that deltoid-splitting approach is significantly superior. Conclusion: Deltoid-splitting approach showed better functional outcomes in the fracture reduction and internal fixation using LCP for the treatment of unstable proximal humerus fractures.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer (비인두암 Split VMAT 치료계획 유용성 평가)

  • Tae Yang Park;Jin Man Kim;Dong Yeol Kwon;Jun Taek Lim;Jong Sik Kim
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose : IMRT using Tomotherapy during nasopharyngeal cancer radiation therapy irradiate an accurate dose to tumor tissues and is effective to reduce a dose rapidly in normal tissues. However, this has high MU and long Beam On Time. This study aims to analyze differences in tumors, normal tissues and low-dose distributions and the efficiency of Split VMAT after applying Helical IMRT (Tomotherapy), VMAT (Linac : 2Arc) and Split VMAT (Linac : 4Arc) plans. Materials and Methods : This study targeted ten nasopharyngeal cancer patients of this hospital and compared three treatment plans (Helical IMRT, VMAT, Split VMAT). For Helical IMRT planning, Precision® (Version 1.1.1.1, Accuray, USA) was used, and for VMAT and Split VMAT planning, Pinnacle (Version 9.10, Philips, USA) was used. The total dose applied was 38.4 Gy / 32 Gy (Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16Fx), and for GTV + 0.3 cm (P_GTV), 95% of V38.4Gy was prescribed. VMAT with an angle of 360° 2Arc was applied, and for Split VMAT, the field was divided into the right, the left, the top and the bottom and an angle of 360° 4Arc, 6MV was set. For evaluating the quality of the treatment plans, differences in tumors, normal tissues and low-dose area were compared, and Beam On Time was measured to analyze the efficiency. Results : When calculating the mean values of evaluation items of the three treatment plans (Helical IMRT, VMAT, Split VMAT) for the patients, the H.I (Homogeneity Index) of P_GTV was 1.04, 1.11 and 1.1 respectively, and the C.I (Confomity Index) of P_CTV was 1.03, 0.99 and 1.00 respectively. The mean dose of RT Parotid Gland (Gy) was 14.54, 17.06 and 14.76 respectively, the mean dose of LT Parotid Gland (Gy) was 14.32, 17.32 and 15.09 respectively, the maximum dose of P_Cord (Spinal Cord + 0.3 cm) (Gy) was 20.57, 22.59 and 21.06 respectively, and the maximum dose of Brain Stem (Gy) was 22.35, 23.99 and 21.68 respectively. The 50% isodose curve (cc) was 1332, 1132.5 and 1065.2 respectively. Beam On Time (sec) was 373.7, 130.7 and 254.4 respectively. Conclusion : Displaying a similar treatment plan quality to Helical IMRT, which is used a lot for head and neck treatment, Split VMAT reduced the low-dose area and Beam On Time and produced a better result than VMAT. Therefore, it is considered that Split VMAT is effective not only for nasopharyngeal cancer but also for other head and neck cancers.

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.