• Title/Summary/Keyword: Neck angle

Search Result 398, Processing Time 0.031 seconds

A CLINICAL STUDY ON FACIAL BONE FRACTURE (악안면 손상에 관한 임상적 연구)

  • Jang, Ki-Young;Shin, Mi-Jeung;Kim, Do-Gyeun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.4
    • /
    • pp.379-388
    • /
    • 1995
  • This study was based on a series of 369 patients with Oral and Maxillofacial injuries treated at Kumi Hospital, College of Medicine, Soon-Chun-Hyang University from Jan. 1992 to Dec. 1994. The results obtained were as follows : 1. The number of male patient was 310 and that of female was 59, leading to 5.3 : 1 of male-female ratio, and the 3rd decade was the highest age group in incidence. 2. Weekly incidence was the highest in Sun. & Sat. and monthly incidence was the highest in Nov.& Oct. 3. Causes as follows : traffic accident 41.9%, slip& fall down 25.4%, human trouble 16.5%, industrial accident 7.5%, sports 6.7%, etc. 4. Site distribution as follows : mandible fracture 32.3%, maxilla fracture 4.8%, zygoma fracture 21.4%, nasal bone fracture 34.1%, orbital& ethmoidal fracture 4.6%. 5. The most common site of mandible was symphysis & angle, and the ratio of OR & CR was 1.3 : 1. 6. The most common site of maxilla was Le Fort 1, 2, and the ratio of OR & CR was 3 : 1. 7. The most common site of zygoma was body, the ratio of OR & CR was 3.3 : 1. 8 . The mean period of intermaxillary fixation was 4.33weeks. 9. Combined injury in facial fracture was 35.8% : The facial fracture were most frequently combind with head & neck(47.0%), upper extremities and abdomen(9.8%). 10. The mean elapsed time from injury to hospital was 1.9days, and that to operation was 5.1days. 11. The mean number of combined teeth injury was 0.6, and percent of combined soft tissue injury of face was 51.3%. 12. Post-operative complication occurred in 4 out of 323 cases. all of that was infection.

  • PDF

A Study on Implementation of Service Robot Platform for Mess-Cleanup (정리정돈용 서비스 로봇 플랫폼의 구현 연구)

  • Kim, Seung-Woo;Kim, Hi-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.5
    • /
    • pp.487-495
    • /
    • 2012
  • In this paper, a Smart Home Service Robot, McBot II, which performs mess-cleanup function etc. in house, is designed much more optimally than other service robots. It is newly developed in much more practical system than McBot I which we had developed two years ago. One characteristic attribute of mobile platforms equipped with a set of dependent wheels is their omni- directionality and the ability to realize complex translational and rotational trajectories for agile navigation in door. An accurate coordination of steering angle and spinning rate of each wheel is necessary for a consistent motion. This paper develops trajectory controller of 3-wheels omni-directional mobile robot using fuzzy azimuth estimator. A specialized anthropomorphic robot manipulator which can be attached to the housemaid robot McBot II, is developed in this paper. This built-in type manipulator consists of both arms with 4 DOF (Degree of Freedom) each and both hands with 3 DOF each. The robotic arm is optimally designed to satisfy both the minimum mechanical size and the maximum workspace. Minimum mass and length are required for the built-in cooperated-arms system. But that makes the workspace so small. This paper proposes optimal design method to overcome the problem by using neck joint to move the arms horizontally forward/backward and waist joint to move them vertically up/down. The robotic hand, which has two fingers and a thumb, is also optimally designed in task-based concept. Finally, the good performance of the developed McBot II is confirmed through live tests of the mess-cleanup task.

A Study on Body Type Characteristics of Chinese-Korean Women between 15 and 17 Years Old Living in China (중국 거주 조선족 15-17세 여성의 체형특성 연구)

  • Im, Soon;Kim, Sang-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.61 no.3
    • /
    • pp.97-110
    • /
    • 2011
  • In this study, the characteristics of body type of Chinese-korean Women between 15 and 17 Years Old Living in China were reviewed by analysing factors and groups in order to provide basic data required to research body types. The following are study results. 1. The study examined average, standard deviation, the minimum value and the maximum value of the 72 items gained from measuring Chinese-korean women between 15~17 years old living in China, and found that 21 items showed more than 4.0 standard deviation among the entire measurements. 2. The current study conducted a factor analysis for the 72 items in order to extract and compare components of body types among Chinese-korean women between 15~17 years old living in China. As a result, 9 factors were extracted, and characteristic values were ranged from 1.15 to 24.71 while the accumulated contributory rate was 75.98%. 3. Chinese-korean women between 15 and 17 years old living in China were classified into three types. Among the 72 items, it was observed that there were differences among groups in 64 items including 15 height items, 10 width items, 16 circumference items, 5 thickness items, 17 length items and weight, excluding neck width, head thickness, shoulder angle, head height, face length, waist back length, scye depth and waist to kip length. 4. As a result of proportion comparison using body indexes of Korean women between 15 and 17 years old living in China and Korea, it was found that, in height item, when regarding the height as 100, Korean women between 15 and 17 years old living in China tended to have longer lower half of the body in relation to the height compared to the Korean.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Endovascular Treatment of 429 Anterior Communicating Artery Aneurysms Using Bare-Platinum Coils : Clinical and Radiologic Outcomes at the Long-term Follow-up

  • Lee, Jong Young;Seo, Jeong Hwa;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.159-166
    • /
    • 2015
  • Objective : We reviewed the feasibility, safety and efficacy as well as the clinical outcome and long-term angiographic results of endovascular treatment (EVT) of the anterior communicating artery (ACoA) aneurysms. Methods : A total of 429 ACoA aneurysms in 426 patients were treated using coil embolization between March 1996 and October 2010 in a single institution. Pretreatment aneurysmal features were checked using angiogram. We had usually used tailored steam shaped microcatheter according to individual angiographic architectures. Immediate postembolization outcomes were evaluated using an angiographic outcome scale and clinical evaluation was performed using the Glasgow Outcome Scale (GOS). Results : Postembolization angiograms demonstrated total occlusion of aneurysm in 290 of 429 (67.6%) aneurysms, neck remnant in 80 (18.6%) and body filling in 59 (13.8%). Dome direction and aneurysm angle was not associated with initial angiographic outcomes. The procedure-related morbidity rate was 0.9% (4 of 429). Clinical and imaging follow-up more than 6 months were available in 382 (89.0%) patients with a mean of 26.2 months. Overall rate of major recanalization was 7.9% (30 of 382) and all of them were retreated without complications. At the last follow-up, 233 (99.2%) of 235 patients had GOS of 5 in unruptured group, and 152 (79.5%) of 191 patients showed good clinical outcomes (GOS of 4 or 5) in ruptured group. Conclusion : Tailored steam shaping of the microcatheter is vital to achieve good angiographic outcomes regardless of aneurysmal direction. EVT is feasible and safe for most ACoA aneurysms with acceptable immediate and long-term outcomes.

Clinical Efficacy of Endovascular Abdominal Aortic Aneurysm Repair

  • Son, Bong-Su;Chung, Sung-Woon;Lee, Chung-Won;Ahn, Hyo-Yeong;Kim, Sang-Pil;Kim, Chang-Won
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.142-147
    • /
    • 2011
  • Background: Endovascular aortic aneurysm repair (EVAR) has come into use and been widely extended because of the low complication rate and less-invasiveness. This article aimed to describe our experience in the treatment of abdominal aortic aneurysm with EVAR. Materials and Methods: A retrospective review was conducted for the 22 patients who underwent EVAR in a single hospital December 2001 to June 2009. Results: The mean age of the patients was $68.5{\pm}7.6$ years. There were several risk factors and comorbidities in 20 patients (90.9%). The mean diameter of the aortic aneurysms was $61.2{\pm}12.9$ mm. The mean length, diameter, and angle of the aneurysmal neck were $30.5{\pm}15.5$ mm, $24.0{\pm}4.5$ mm, and $43.9{\pm}16.0^{\circ}$, respectively. The mean follow-up period of the patients was $28.8{\pm}29.5$ months. The 30-day postoperative mortality was none. Seven patients (31.8%) had endoleaks during the hospital stay and three patients (13.6%) had endoleaks during the follow-up period. One patient (4.5%) died due to a ruptured aortic aneurysm. The cumulative patient survival rates were 88.2%, 88.2%, and 70.6% at 1, 3, and 5 years of follow-up, respectively. Conclusion: EVAR is currently a safe, feasible procedure for high risk patients with abdominal aortic aneurysm because of low postoperative complication and mortality if patients are selected properly and followed up carefully.

Analysis of Technical Error of Manual Measurements (직접 측정한 인체치수의 기술적 오차 분석)

  • Park, Jinhee;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

Effects of Masseter and Cervical Muscle Activity in Temporomandibular Joint Disorder (저작근 및 경부근 긴장도가 측두하악장애에 미치는 영향)

  • Jung, Jae-Young;Kim, Sung-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.3
    • /
    • pp.37-60
    • /
    • 2010
  • Objectives : The purpose of this study was to investigate the relationship between masseter and cervical muscle activity and temporomandibular disorder in female office workers. Methods : Experimental group of 24 healthy subjects complained of temporomandibular joint related to computer use which lasted more than 3 months in the past year and was present in the past 7 days as well as on the day of test. Control group of 20 healthy subjects had no complaints of minimal discomfort on the day of test, and had no discomfort in the past 7 days. If they had reported discomfort in the past 12 months, it was of a short duration(<3 months) and resolved at least 3 months prior to participation. Outcomes were assessed by meridian-electromyography(MEMG), whole spin x-ray, mandibular function impairment questionnaire(MFIQ), neck disability index(NDI), visual analog scale(VAS), Beck depression inventory(BDI), stress reaction inventory(SRI) and Holmes & Rahe social readjustment rating scale(SRRS). Results : The contraction power of masseter muscle, upper trapezius, sternocleido-mastoid muscle and erector spinae by MEMG was significantly higher in the experimental group. The muscle fatigue of masseter muscle and sternodeido-mastoid muscle by MEMG was significantly higher in the experimental group. SRI was significantly higher in experimental group. There was no significant difference between two groups in the Jackson's angle, Cobb's method and cranio-cervical posture. Conclusions : The results suggest that temporomandibular disorder related mental stress but physical stress does not change cervical structure significantly.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.