• Title/Summary/Keyword: Near-infrared Image

Search Result 187, Processing Time 0.034 seconds

Extraction of DEM in the Southern Tidal Flat of Kanghwa Island using Satellite Image (위성영상을 이용한 강화도 남단갯벌의 DEM 추출)

  • 박성우;정종철
    • Spatial Information Research
    • /
    • v.11 no.1
    • /
    • pp.13-22
    • /
    • 2003
  • The study of geomorphology of tidal flat using remote sensing image has been considered useful because of it's ability to acquire data periodically. Especially, the Near Infrared band of satellite image has been used to divide between land and sea area. This study extracted a borderline of the tidal flat using Landsat-5 images and generated DEM(Digital elevation model) using tide level data as elevation value. DEM is a useful tool for three-dimensional survey of geomorphology and can be used for survey of tidal flat. This study divided 8 images of 1990's into two parts - before 1994 and after 1994 - and generated DEM respectively. In this work, the areas of tidal flats are calculated and it was revealed the area of tidal flat was decreased after 1994.

  • PDF

NIR Fluorescence Imaging Systems with Optical Packaging Technology

  • Yang, Andrew Wootae;Cho, Sang Uk;Jeong, Myung Yung;Choi, Hak Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2014
  • Bioimaging has advanced the field of nanomedicine, drug delivery, and tissue engineering by directly visualizing the dynamic mechanism of diagnostic agents or therapeutic drugs in the body. In particular, wide-field, planar, near-infrared (NIR) fluorescence imaging has the potential to revolutionize human surgery by providing real-time image guidance to surgeons for target tissues to be resected and vital tissues to be preserved. In this review, we introduce the principles of NIR fluorescence imaging and analyze currently available NIR fluorescence imaging systems with special focus on optical source and packaging. We also introduce the evolution of the FLARE intraoperative imaging technology as an example for image-guided surgery.

Optical Imaging Technology for Real-time Tumor Monitoring

  • Shin, Yoo-kyoung;Eom, Joo Beom
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.123-131
    • /
    • 2021
  • Optical imaging modalities with properties of real-time, non-invasive, in vivo, and high resolution for image-guided surgery have been widely studied. In this review, we introduce two optical imaging systems, that could be the core of image-guided surgery and introduce the system configuration, implementation, and operation methods. First, we introduce the optical coherence tomography (OCT) system implemented by our research group. This system is implemented based on a swept-source, and the system has an axial resolution of 11 ㎛ and a lateral resolution of 22 ㎛. Second, we introduce a fluorescence imaging system. The fluorescence imaging system was implemented based on the absorption and fluorescence wavelength of indocyanine green (ICG), with a light-emitting diode (LED) light source. To confirm the performance of the two imaging systems, human malignant melanoma cells were injected into BALB/c nude mice to create a xenograft model and using this, OCT images of cancer and pathological slide images were compared. In addition, in a mouse model, an intravenous injection of indocyanine green was used with a fluorescence imaging system to detect real-time images moving along blood vessels and to detect sentinel lymph nodes, which could be very important for cancer staging. Finally, polarization-sensitive OCT to find the boundaries of cancer in real-time and real-time image-guided surgery using a developed contrast agent and fluorescence imaging system were introduced.

THE AKARI PROJECT: LEGACY AND DATA PROCESSING STATUS

  • NakagawaI, Takao;Yamamura, Issei
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.5-9
    • /
    • 2017
  • This paper provides an overview of the AKARI mission, which was the first Japanese satellite dedicated to infrared astronomy. The AKARI satellite was launched in 2006, and performed both an all-sky survey and pointed observations during its 550 days in the He-cooled mission phases (Phases 1 and 2). After the He ran out, we continued near-infrared observations with mechanical cryocoolers (Phase 3). Due to a failure of its power supply, AKARI was turned off in 2011. The AKARI data are unique in terms of the observed wavelengths as well as the sky coverage, and provide a unique legacy resource for many astronomical studies. Since April 2013, a dedicated new team has been working to refine the AKARI data processing. The goal of this activity is to provide processed datasets for most of the AKARI observations in a Science Ready form, so that more users can utilize the AKARI data in their astronomical research. The data to be released will include revised All-Sky Point Source Catalogues, All-Sky Image Maps, as well as high-sensitivity images and spectra obtained by pointed observations. We expect that the data will be made public by in the Spring of 2016.

Selecting Significant Wavelengths to Predict Chlorophyll Content of Grafted Cucumber Seedlings Using Hyperspectral Images

  • Jang, Sung Hyuk;Hwang, Yong Kee;Lee, Ho Jun;Lee, Jae Su;Kim, Yong Hyeon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.681-692
    • /
    • 2018
  • This study was performed to select the significant wavelengths for predicting the chlorophyll content of grafted cucumber seedlings using hyperspectral images. The visible and near-infrared (VNIR) images and the short-wave infrared images of cucumber cotyledon samples were measured by two hyperspectral cameras. A correlation coefficient spectrum (CCS), a stepwise multiple linear regression (SMLR), and partial least squares (PLS) regression were used to determine significant wavelengths. Some wavelengths at 501, 505, 510, 543, 548, 619, 718, 723, and 727 nm were selected by CCS, SMLR, and PLS as significant wavelengths for estimating chlorophyll content. The results from the calibration models built by SMLR and PLS showed fair relationship between measured and predicted chlorophyll concentration. It was concluded that the hyperspectral imaging technique in the VNIR region is suggested effective for estimating the chlorophyll content of grafted cucumber leaves, non-destructively.

Image Restoration Considering Chromatic Aberration Problem of Multi-Spectral Filter Array Image (다중 분광 필터 배열 영상의 색수차 문제를 고려한 영상 복원 알고리즘)

  • Kwon, Ji Yong;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.123-131
    • /
    • 2016
  • To capture color and near-infrared images simultaneously, a multi-spectral filter array(MSFA) sensor is used. This is because an NIR band gives additional invisible information to human eyes to see subject under extremely low light level. However, because lenses have different refractive indices for different wavelengths, lenses may fail to focus widely different rays to the same convergence point. This is why a chromatic aberration(CA) problem occurs and images are degraded. In this paper, the image restoration algorithm for an MSFA image, which removes the CA problem, is presented. The obtained MSFA image is filtered by the estimated low-pass kernel to generate a base image. This base image is used to remove CA problem in multi-spectral(MS) images. By modeling the image degradation process and by using the least squares approach of the difference between the high-frequencies of the base and MS images, the desired high-resolution MS images are reconstructed. The experimental results show that the proposed algorithm performs well in estimating the high-quality MS images and reducing the chromatic aberration problem.

A Study on Characteristics Analysis of Multichannel Filter Module for Near-infrared Fluorescence Imaging (근적외선 형광 이미징 영상 구현을 위한 다채널 필터 모듈 특성분석 연구)

  • Choi, Jinsoo;Cho, Sang Uk;Kim, Doo-In;Lee, Hak-Guen;Choi, Hak Soo;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, development of multichannel filter module and characteristic evaluation for bio imaging were studied. The filter module was fabricated in order to realize near infrared fluorescence imaging of 700 nm and 800 nm wavelength ranges, and contrast imaging analysis for characteristic evaluation of the filter module was studied through signal to back ground ratio (SBR), controlled by parameters such as magnification, exposure, gain. Furthermore, phantoms, which are biomimetic tissue with equal optical properties of kidney and liver, were fabricated to study characteristics of both filter module depending on thickness and exposure amount of light source for bio imaging analysis. The fabricated filter module has more than 4 of SBR difference despite changes of magnification, exposure, gain, and in the case of the kidney phantom and the liver phantom, contrast imaging of more than 4 of SBR was confirmed on 50 mA, 60 mA exposure amount of light source respectively.

Transparent Near-infrared Absorbing Dyes and Applications (투명 근적외선 흡수 염료 및 응용 분야)

  • Hyocheol Jung;Ji-Eun Jeong;Sang-Ho Lee;Jin Chul Kim;Young Il Park
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.207-212
    • /
    • 2023
  • Near-infrared (NIR) absorbing dyes have been applied to various applications such as optical filters, biotechnology, energy storage and conversion, coating additive, and traditionally information-storage materials. Because image sensors used in cellphones and digital cameras have sensitivity in the NIR region, the NIR cut-off filter is essential to achieving more clear images. As energy storage and conversion have been important, diverse NIR absorbing materials have been developed to extend the absorption region to the NIR region, and NIR absorbing materials-based research has proceeded to improve device performances. Adding NIR-absorbing dye with a photo-thermal effect to a self-healable coating system has been attractive for future mobility technology, and more effective self-healing properties have been reported. In this report, the chemical structures of representative NIR-absorbing dyes and state of the art research based on NIR-absorbing dyes are introduced.

Sea Surface Temperature Analysis for the Areas near Gwang-Yang Steel Mill using LANDSAT Thermal Data (Landsat 열적외선 위성자료를 이용한 광양제철소 주변 해역 해수표면온도 분석)

  • Kim, Sang-Min;Kim, Chang-Jae;Han, Soo-Hee;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.123-131
    • /
    • 2011
  • Characteristics of sea surface temperature(SST) difference around Gwang-Yang steel Mill where can affect marine ecosystem in Gwang-Yang bay using 25 collected Landsat-7 ETM+ thermal infrared band data from 2000 to 2010. To analyze accuracy of SST from the Landsat-7 ETM+ thermal infrared image, satellite-induced SST was verfied by compared Yeo-Su tide station and Landsat thermal image. As a result, SST from Landsat-7 ETM+ is $1.22^{\circ}C$ lower than sea temperature from Yeo-Su tide station and correlation coefficient resulted in above 0.991 which means that correlation coefficient between Landsat image temperature and field sea temperature is relatively high. Five regions were selected to analyze sea surface temperature between near Gwang-Yang steel mill and the open sea and analyzed timeseries of sea surface temperature seasonally and regionally. Moreover, the additional analysis has been carried out by comparing the averaged temperatures of Gwang-Yang and Soon-Cheon bays using the dataset over a year.

Optical Design of a Modified Catadioptric Omnidirectional Optical System for a Capsule Endoscope to Image Simultaneously Front and Side Views on a RGB/NIR CMOS Sensor (RGB/NIR CMOS 센서에서 정면 영상과 측면 영상을 동시에 결상하는 캡슐 내시경용 개선된 반사굴절식 전방위 광학계의 광학 설계)

  • Hong, Young-Gee;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.286-295
    • /
    • 2021
  • A modified catadioptric omnidirectional optical system (MCOOS) using an RGB/NIR CMOS sensor is optically designed for a capsule endoscope with the front field of view (FOV) in visible light (RGB) and side FOV in visible and near-infrared (NIR) light. The front image is captured by the front imaging lens system of the MCOOS, which consists of an additional three lenses arranged behind the secondary mirror of the catadioptric omnidirectional optical system (COOS) and the imaging lens system of the COOS. The side image is properly formed by the COOS. The Nyquist frequencies of the sensor in the RGB and NIR spectra are 90 lp/mm and 180 lp/mm, respectively. The overall length of 12 mm, F-number of 3.5, and two half-angles of front and side half FOV of 70° and 50°-120° of the MCOOS are determined by the design specifications. As a result, a spatial frequency of 154 lp/mm at a modulation transfer function (MTF) of 0.3, a depth of focus (DOF) of -0.051-+0.052 mm, and a cumulative probability of tolerance (CPT) of 99% are obtained from the COOS. Also, the spatial frequency at MTF of 170 lp/mm, DOF of -0.035-0.051 mm, and CPT of 99.9% are attained from the front-imaging lens system of the optimized MCOOS.