• Title/Summary/Keyword: Near-infrared (NIR) spectroscopy

Search Result 373, Processing Time 0.027 seconds

DETECTION OF SOY, PEA AND WHEAT PROTEINS IN MILK POWDER BY NIRS

  • Cattaneo, Tiziana M.P.;Maraboli, Adele;Barzaghi, Stefania;Giangiacomo, Roberto
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1156-1156
    • /
    • 2001
  • This work aimed to prove the feasibility of NIR spectroscopy to detect vegetable protein isolates (soy, pea and wheat) in milk powder. Two hundred and thirty-nine samples of genuine and adulterated milk powder (NIZO, Ede, NL) were analysed by NIRS using an InfraAlyzer 500 (Bran+Luebbe). NIR spectra were collected at room temperature, and data were processed by using Sesame Software (Bran+Luebbe). Separated calibrations for each non-milk protein added, in the range of 0-5%, were calculated. NIR data were processed by using Sesame Software (Bran+Luebbe). Prediction and validation were made by using a set of samples not included into the calibration set. The best calibrations were obtained by the PLSR. The type of data pre-treatment (normalisation, 1$\^$st/ derivative, etc..) was chosen to optimize the calibration parameters. NIRS technique was able to predict with good accuracy the percentage of each vegetable protein added to milk powder (soy: R$^2$ 0.994, SEE 0.193, SEcv 0.301, RMSEPall 0.148; pea: R$^2$ 0.997, SEE 0.1498, SEcv 0.207, RMSEPall 0.148, wheat: R$^2$ 0.997, SEE 0.1418, SEcv 0.335, RMSEPall 0.149). Prediction results were compared to those obtained using other two techniques: capillary electrophoresis and competitive ELISA. On the basis of the known true values of non-vegetable protein contents, the NIRS was able to determine more accurately than the other two techniques the percentage of adulteration in the analysed samples.

  • PDF

THE ANALYSIS OF THE FT-NIR SPECTRA OF WATER ON THE BASIS OF TWO-STATE MODEL

  • Boguslawa, Czarnik-Matusewicz
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1181-1181
    • /
    • 2001
  • Robinson with ${coworkers}^{1}$ have introduced two-state outer-neighbor bonding model to explain the anomalies of water. The studies on the properties of water as a function of temperature and pressure revealed that, unlike other ideas, all $H_2O$ molecules in liquid are tetrabonded. On the average they are forming two different bonding types. One type is the regular tetrahedral water-water bonding similar to that found in the ordinary ice Ih, whereas the other is a more dense nonregular tetrahedral bonding similar to that appearing in the ice II. The transformation between these two bonding forms is evidenced by FT-NIR experiment. The FT-NIR measurements were done for liquid water in the temperature range from $20^{\circ}C$ up to $80^{\circ}C$ in a wide extent of frequencies: 12 000 - 4000 $cm^{-1}$ /. Temperature dependent variations in the volume fraction of these two structures are directly related to the spectral changes. The absorbance variations are explored by means of the two-dimensional correlation spectroscopy (2DCOS), principal component analysis (PCA), curve fitting and second derivatives. The presence of the isosbestic points in a range of the combination and overtone transitions indicates that the experimental spectra are a superposition of two temperature independent components. One component of diminishing intensity with temperature increase, is assigned to a stronger hydrogen bonds occurred in the Ih type, whereas the second component showing an opposite behavior, one can attribute to a weaker H-bonds characteristic for the II type. The understanding of the hydrogen bonding network in the liquid water is very important in interpretation of the interaction between water and protein chain. The two-state model of water surrounding the protein surface could advance an understanding of the hydration process.

  • PDF

Near-Infrared Spectroscopy for Monitoring Cerebral Hemodynamics in Hyperbilirubinemia-induced Newborn Piglets (고빌리루빈혈증이 유도된 신생자돈에서 근적외석 발광기를 이용한 뇌 혈역학적 변화에 대한 연구)

  • Hwang, Jong Hee;Choi, Chang Won;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.649-654
    • /
    • 2005
  • Purpose : The present study examined how changes in cerebral hemodynamics in newborn piglets with bilirubin infusion can be evaluated by near infrared sepctroscopy(NIRS). Methods : Seventeen newborn piglets were randomly divided into the following three experimental groups : six in the control group(CG); seven in the bilirubin infusion group(BG), and four in the bilirubin infusion with 7-nitroindazole group(NG). To achieve the concentration of bilirubin above 20 mg/dL, we injected a bolus of 40 mg/kg of bilirubin intravenously, followed by 30 mg/kg/hr of bilirubin continuous intravenous infusion. All groups were monitored with cerebral hemodynamics using near infrared spectroscopy(NIRS) and their brain cortexes were harvested and the activities of $Na^+$, $K^+$-ATPase, level of conjugated dienes, ATP and phosphocreatine(PCr) were determined biochemically. Results : No changes took place in CG. In BG and NG, base excess, pH, and MABP decreased, and lactate level in blood increased. Cerebral $Na^+$, $K^+$-ATPase activity and ATP, PCr level in BG significantly decreased and conjugated dienes increased compared to CG. These abnormalities observed in the BG were significantly improved in the NG. In continuous NIRS monitoring, [$HbO_2$], [HbT], and [HbD] in BG were significantlly decreased compared to CG. However these abnormalities between NG and CG were not significantly different. There were no significant differences in $ScO_2$ between the study groups. Conclusion : Our study suggests cerebral hemodynamic changes could be monitored by non-invasive NIRS in newborn piglets with bilirubin infusion.

Utilization of Near Infrared Spectroscopy for Analysis of Proximate Composition and Starch in Alaska Pollack Surimi (명태 수리미의 일반성분 및 전분의 분석을 위한 근적외선 분광분석법의 이용)

  • Song Ho Su;Lee Keun Tai;Park Seong Min;Hwang Sun Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.4
    • /
    • pp.321-326
    • /
    • 2002
  • Near infrared spectroscopy (NIR), is recently applied to analysis of food, and it gives non-destructive and highly reproducible results. The objectives of this study were to assay protein, lipid and starch content in Alaska pollack surimi and to investigate application in seafood. NIR spectra showed the absorbance signal at 1,510 nm, 2,050 nm, 2,170 nm and 2,180 nm for protein, and signal were increased with protein content. Standard error of equation (SEE) was 0,296 and standard error of prediction (SEP) was 0.327. In analysis of lipid in Alaska pollack surimi by NIR, near infrared spectra of lyophilized Alaska pollack surimi were scanned and the signals of absorbance from C-H functional groups in lipid were identified at 1,730 nm, 1,740 nm and 2,300 nm and these signals were risen as Increasing lipid contents of Alaska pollack surimi as samely protein. SEE and SEP were 0.319, 0,353, respectively. In starch analysis using NIR the signals of starch distinctly changed at wavelength of 1,450 nm and 1,950 nm. Collected values of SEE and SEP were 0.304 and 0.318, respectively and the range of errors was $0.0186\~0.6470$ in starch contents.

Quantification of Icariin Contents in Epimedium koreanum N. by Using a Near Infrared Reflectance Spectroscopy (NIRS를 이용한 삼지구엽초의 이카린 함량 분석)

  • Kim, Yong-Ho;Choi, Byoung-Ryourl;Baek, Hum-Young;Lee, Young-Sang
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.5
    • /
    • pp.340-343
    • /
    • 2002
  • Near infrared reflectance spectroscopy (NIRS) has become widely accepted for rapid quantitative analysis of components in some crops. Our object was to determine icariin contents in whole plant of Epimedium koreanum by using an NIRS system. Total 150 plant samples previously analyzed by HPLC were scanned by NIRS and 68 samples were selected for calibration and validation equation. A calibration equation calculated by MPLS(modified partial least squares) regression technique was developed and a coefficient of determination in calibration and validation sets were 0.95 and 0.82, respectively. A comparison between NIRS estimation and HPLC value was performed with the remaining samples not included in the calibration and validation sets. Most of samples also showed a positive correlation like a validation set. Our results demonstrate that this developed NIRS equation can be practically used as a mass screening method for rapid quantification of icarin contents in Epimedium koreanum N.

NIR PREDICTIONS OF INDIRECT RESPONSES

  • Claridge, Rovert-Burling;Ross Clarke
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3103-3103
    • /
    • 2001
  • NIR has been extensively used to predict directly measurable properties of materials that are important to the appropriate industries. Commonly, NIR is used to perform fast, routine tests to improve control response as against the response time for the (normally chemical) base test. This paper discusses the use of NIR to measure indirect properties of materials. In these cases, the pure chemical or physical tests are either unable measure the appropriate parameters (eg GMO modification) or there are mitigating effects that are not properly addressed by the base tests. In particular, we looked at the digestible portion of amino acids within meat and bone meal. This is the desired response measurement by end-users of the product (intensive livestock producers) but is currently unable to be offered as a measurement by producers. The base test method is by controlled feeding trials. These are somewhat cumbersome, taking 2-3 months, involving several sets of animals, and considerable expense. A shortened test (feed trial based) would be of little use, as the precision blows out over short period feeding trials. For example, a rat ileal digestibility test requires around 2 months, and costs some $USD1000. This is clearly impractical test for a producer involved in continuous production, with a 1-2 day turn around. While the amino acid abundance is accessible chemically, the uptake of amino acids into usable material by mammalian species is not simply related to the measured abundance within the material. There are many co-related material properties that might help or hinder uptake, some chemical based (eg protein damage), some indirect (eg palatability), some physiological (intestinal tract response vs speed of throughput). We discuss the approaches taken to provide a suitable reference data set, and present the derived prediction and validation relationships.

  • PDF

Quality Prediction of Kiwifruit Based on Near Infrared Spectroscopy

  • Lee, Jin Su;Kim, Seong-Cheol;Seong, Ki Cheol;Kim, Chun-Hwan;Um, Yeong Cheol;Lee, Seung-Koo
    • Horticultural Science & Technology
    • /
    • v.30 no.6
    • /
    • pp.709-717
    • /
    • 2012
  • To establish the standard of ripe kiwifruit sorting, near infrared (NIR) spectroscopy was performed on kiwifruit sampled from three farms. Destructive measurements of flesh firmness, soluble solids content (SSC), and acidity were performed and compared to measurement using NIR reflectance spectrums from 408 to 2,492 nm. NIR predictions of those quality factors were calculated using the modified partial least square regression method. Flesh firmness was predicted with a standard error of prediction (SEP) of 3.32 N and with a correlation coefficient ($R^2$) of 0.88. SSC was predicted with SEP of $0.49^{\circ}Brix$ and with $R^2$ of 0.98. Acidity was predicted with SEP of 0.28% and with $R^2$ of 0.91. Kiwifruit ripened at $20^{\circ}C$ for 15 days showed uneven qualities with normal distribution. Considering the SEP of each parameter, kiwifruit after ripening treatment could be non-destructively predicted their qualities and sorted by flesh firmness or soluble solids content through NIR prediction.

A Study for Automatic Analysis of Qualysis of Quality Components in Tabacco Leaves Using Non-destructive Analytical Method (근적외 분광분석법에 의한 잎담배의 품질측정 자동화)

  • Cho, Rae-Kwang;Lee, Kyung-Hee;Lee, Jung-Hwan;Kwon, Yong-Kil
    • Applied Biological Chemistry
    • /
    • v.37 no.5
    • /
    • pp.349-355
    • /
    • 1994
  • The present study was conducted to develop the automatic analytical method for determining moisture, nicotine, reducing sugar and total nitrogen contents and color(L, a, b) value in domestic tobacco leaves using near infrared(NIR) spectroscopy. The results of multiple linear regression analysis between chemical and NIR data showed that NIR spectro-scopy can determine those quality components of tobacco samples in 30 seconds, non-destructively. The results using developed calibrations are summarized as follows; The standard error of prediction(SEP) for moisture, nicotine. total nitrogen, reducing sugar contents and color(L, a, b) value in domestic tobacco leaves was 0.28%, 0.25%, 0.07%, 0.75%, 1.25, 0.44 and 1.07, respectively. In addition, The possibility of developing the cheaper filter type NIR instrument, for quality evaluation in the procurement from leaf tobacco cultivators and process control was investigated.

  • PDF

Variey Discrimination of Sorghum-Sudangrass Hybrids Seed Using near Infrared Spectroscopy (근적외선분광법을 이용한 수수×수단그라스 교잡종 종자의 품종 판별)

  • Lee, Ki-Won;Song, Yowook;Kim, Ji Hye;Rahman, Md Atikur;Oh, Mirae;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • The aim of this study was to investigate the feasibility of discrimination 12 different cultivar of sorghum × sudangrass hybrid (Sorghum genus) seed through near infrared spectroscopy (NIRS). The amount of samples for develop to the best discriminant equation was 360. Whole samples were applied different three spectra range (visible, NIR and full range) within 680-2500 nm wavelength and the spectrastar 2500 Near near infrared was used to measure spectra. The calibration equation for discriminant analysis was developed partial least square (PLS) regression and discrimination equation (DE) analysis. The PLS discriminant analysis model for three spectra range developed with mathematic pretreatment 1,8,8,1 successfully discriminated 12 different sorghum genus. External validation indicated that all samples were discriminated correctly. The whole discriminant accuracy shown 82 ~ 100 % in NIR full range spectra. The results demonstrated the usefulness of NIRS combined with chemometrics as a rapid method for discrimination of sorghum × sudangrass hybrid cultivar through seed.

Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF