• Title/Summary/Keyword: Near infrared

Search Result 1,693, Processing Time 0.033 seconds

Quantitative Analysis of Taurine Using Near Infrared Spectrometry (NIRS) (근적외선 분광분석법을 이용한 타우린의 정량 분석)

  • Cho, Chang-Hee;Kim, Hyo-Jin;Meang, Dae-Young;Seo, Sang-Hun;Cho, Jung-Hwan
    • YAKHAK HOEJI
    • /
    • v.42 no.6
    • /
    • pp.545-551
    • /
    • 1998
  • Near Infrared transmittance Spectroscopy (NIRS) was used to evaluate and quantify the pharmaceutical active compounds. In the paper, taurine (2-Aminoethanesulfonic acid) was quantitatively analyzed in commercial pharmaceutical preparations. For calibration a central composite factorial design was used to determine concentrations of ingredients in reference samples. For the quantitative analysis of taurine, the most suitable data analysis method includes the calculation of second derivatives and a partial least squares regression (PLSR) model. By NIR spectrometry, combined with PLSR, the taurine concentration was successfully predicted with a relative standard error of prediction (SEP) lower than 1.04%.

  • PDF

Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System (휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정)

  • 강나루;우영아;차봉수;이현철;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Infrared Target Extraction Using Weighted Information Entropy and Adaptive Opening Filter

  • Bae, Tae Wuk;Kim, Hwi Gang;Kim, Young Choon;Ahn, Sang Ho
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.1023-1031
    • /
    • 2015
  • In infrared (IR) images, near targets have a transient distribution at the boundary region, as opposed to a steady one at the inner region. Based on this fact, this paper proposes a novel IR target extraction method that uses both a weighted information entropy (WIE) and an adaptive opening filter to extract near finely shaped targets in IR images. Firstly, the boundary region of a target is detected using a local variance WIE of an original image. Next, a coarse target region is estimated via a labeling process used on the boundary region of the target. From the estimated coarse target region, a fine target shape is extracted by means of an opening filter having an adaptive structure element. The size of the structure element is decided in accordance with the width information of the target boundary and mean WIE values of windows of varying size. Our experimental results show that the proposed method obtains a better extraction performance than existing algorithms.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Applications of Near Infrared Reflectance Spectroscopy(NIRS) in Forage Evaluation (조사료 가치 평가를 위한 근적외선 분광법(NIRS)의 활용)

  • 박형수;이종경;이효원
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.24 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • Farmers need timely information on the nutritional status of their animals and the nutritive value of pastures and supplementary feeds if they are to apply successfully this existing nutritional information. Near infrared reflectance(NIR) spectroscopy has been used over the last forty years to analyse accurately protein, fiber, and other organic components in animal foods. NIR spectroscopy is a rapid, non-destructive, and non-polluting technology. When properly calibrated, NIR spectroscopy is used successfully with both concentrate and forage feeds. NIR methods predict in vitro digestibility accurately and precisely, and can predict in vivo digestibility at least as well as conventional "wet chemistry" methods such as in vivo digestion or the pepsin-cellulase method, and much more rapidly. NIR technology has been applied to the routine monitoring (through analysis of feces samples) of the nutritional status of cattle and other grazing animals. This report reviews the use of near infrared reflectance(NIR) spectroscopy to monitor the nutritive value of animal feeds and the nutritional status of grazing animals.

Implemented of non-destructive intelligent fruit Brix(sugar content) automatic measurement system (비파괴 지능형 과일 당도 자동 측정 시스템 구현)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.433-439
    • /
    • 2020
  • Recently, the need for IoT-based intelligent systems is increasing in various fields. In this study, we implemented the system that automatically measures the sugar content of fruits without damage to fruit's marketability using near-infrared radiation and machine learning. The spectrums were measured several times by passing a broadband near-infrared light through a fruit, and the average value for them was used as the input raw data of the machine-learned DNN(Deep Neural Network). Using this system, he sugar content value of fruits could be predicted within 5 s, and the prediction accuracy was about 93.86%. The proposed non-destructive sugar content measurement system can predict a relatively accurate sugar content value within a short period of time, so it is considered to have sufficient potential for practical use.

Application for Measuring the Glucose, Ammonia nitrogen, and Tylosin Concentration using Near Infrared Spectroscopy

  • Kim, Jong-Soo;Cho, Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.19-25
    • /
    • 2008
  • For measurement of tylosin, ammonia nitrogen, and glucose concentration during the culture of Streptomyces fradiae using Near Infrared Spectroscopy, the calibration using various mathematical models was performed and then, based on the linear model, the validation was carried out. In the case of sucrose concentration using the MLR method, the Standard Error of Prediction and Multiple correlation coefficient were 1.97, and 0.991, respectively. In the case of ammonia nitrogen concentration using the PLSR method, the Standard Error of Prediction and Multiple correlation coefficient were 0.13, and 0.990, respectively. In the case of tylosin concentration using the PLSR method, the standard Error of Prediction and Multiple correlation coefficient were 0.54, and 0.984, respectively.

Near-infrared Spectroscopic Measurement of Glucose Under the Existence of Other Major Blood Components (혈액의 주요 구성물질 존재 하에서 근적외분광분석법을 이용한 글루코오스 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.171-176
    • /
    • 2004
  • This study was described for measuring clinically relevant levels of glucose in undiluted plasma and whole blood by near-infrared (NIR) spectroscopy. Result from an initial measurement of major blood components powder was over-lapped the absorption bands of glucose at 1500-1600 nm. However, the NIR data of blood components were clearly separated by principle component analysis (PCA) space. By the use of partial least squares (PLS) regression, glucose concentrations in undiluted plasma and whole blood could be determined with standard errors of prediction (SEP) of 15 mg/dl and 76 mg/dl, respectively. Although these blood components possessed strong absorption bands that overlapped with the absorption bands of glucose, successful calibration models could be carried out.

Dissolution Test for Indomethacin by the Portable Near-Infrared(NIR) System

  • Kim, Do-Hyung;Lim, Hun-Rang;Chang, Soo-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.399.3-399.3
    • /
    • 2002
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test for tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50ppm using mixture of phosphate buffer(pH 7,2) and water(1:4), The near infrared(NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2mm pathlength, Partial least-square regression (PLSR) was explored to develop calibration models over the spectral range 1100-1700nm. (omitted)

  • PDF