• Title/Summary/Keyword: Near horizontal heterophoria

Search Result 6, Processing Time 0.019 seconds

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

A Study on The Measurement and Tendency of Horizontal Heterophoria Using Von Graefe Method (Von graefe법을 이용한 사위의 측정과 경향에 관한 연구)

  • Lee, Ki-Seok;Jung, Mi-Boon;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • We researched distant & near horizontal heterophoria of myope using von graefe method on full correction condition for young people 49 subjects(98eyes) with myopia after testing the objective refraction. Among the whole subjects, we got the results as Orthophoria 51.00%, Exophoria 38.75%, Esophoria 10.25% and Heterophoria 49.00% at a long distant. At a short distant, they showed Orthophoria 22.45%, Exophoria 67.35, Esophoria 10.20%, and Heterophoria 77.55%, Orthophoria 22.45. At a long distant they showed Orthophoria 4.08%, Exophoria 8.16%, Esophoria 0% on high myopia, Orthophoria 18.37%, Exophoria 12.25%, Esophoria 0% on middle myopia and Orthophoria 28.57%, Exophoria 18.37%, Esophoria 10.20% on low myopia.

  • PDF

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

The Study on the Property of The Heterophoria and Fusional Reserve in Adults in Jeon-buk Area (전북지역 성인의 사위와 융합여력 특성에 관한 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Sim, Sang-Hyun;Choi, Sun Mi;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.661-666
    • /
    • 2013
  • The aim of this study was to evaluate the property of heterophoria and fusional reserve in Adults in Jeon-buk Area. We examined the corrected visual acuity, corrected refractive error, heterophoria and fusional reserve of 116 healthy myopes aged from 20 to 44 old who had no strabismus no ocular and phyisical diseases. Using Von Graefe test of horizontal heterophoria Measurement, we measured orthophoria(26.7%), exophoria(52.5%) and esophoria(20.7%) for at near distance. The subjects who had exophoria of 0-6${\Delta}$ in the range of normal state was 38.8%, while the subjects who had exophoria in the range of abnormal state was 61.2%. Reducing fusional reserve was associated with increasing phoria. We found a relationship between asthenopia and fusional reserve of heterophoria and considered that fusional reserve must be examined when we preserve for a patient with heterophoria. Furthermore, Gradient method AC/A ratio was found 4.03 and its relationship to refractive error could not be determined.

Relationship Between Subjective Symptoms with Near Work and Binocular Function (근업시 자각 증상과 양안시 기능의 관계)

  • Shin, Jin-Ah;Lee, Ok-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.125-130
    • /
    • 2007
  • The aim of this work was to study the relationship between subjective symptoms and binocular function during near work in forty one(12-17yr) schoolchildren. CISS symptom survey, amplitude of accommodation, accommodative facility, neagative relative accommodation(NRA)/positive relative accommodation(PRA) near point of convergence(NPC), heterophoria, AC/A ratios were measured. The results of measurement were compared with normal expected value of each test and classified into normal and abnormal group. Accommodative insufficiency was more general than convergence insufficiency and esophoria was greater than exophoria. NRA/PRA showed very high and AC/A ratios were very low compare with normal expected value. The results of CISS was as follows; most frequent symptom was tired, mean score was $16.63{\pm}7.49$, mean number of symptoms were $10.07{\pm}3.04$, and mean number of serious symptoms were $1.98{\pm}2.13$. After classified into 4 groups according to score of symptoms, number of symptoms, and degree of symptoms and then analyze the correlation compare with binocular vision test results. NRA was most correlated with group comparison, accommodative facility was most correlated with score of symptoms, NRA was most correlated with number of symptoms, and near horizontal phorias were most correlated with serious symptoms. NRA showed most correlative relation with near symptoms.

  • PDF

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.