터빈 동익 스퀼러팁 표면에서의 열(물질)전달 특성 (Heat/Mass Transfer Characteristics on the Squealer Tip Surface of a Turbine Rotor Blade)

  • 문현석;이상우
    • 한국유체기계학회 논문집
    • /
    • 제12권1호
    • /
    • pp.35-42
    • /
    • 2009
  • The flow and heat/mass transfer characteristics on the squealer tip surface of a high-turning turbine rotor blade have been investigated at a Reynolds number of $2.09{\times}10^5$, by employing the oil-film flow visualization and naphthalene sublimation technique. The squealer rim height-to-chord ratio and tip gap height-to-chord ratio are fixed as typical values of $h_{st}/c$ = 5.5% and h/c = 2.0%, respectively, for turbulence intensities of Tu = 0.3% and 15%. The results show that the near-wall flow phenomena within the cavity of the squealer tip are totally different from those over the plane tip. There are complicated backward flows from the suction side to the pressure side near the cavity floor, in contrast to the plane tip gap flows moving toward the suction side after flow separation/reattachment. The squealer tip provides a significant reduction in tip surface thermal load with less severe gradient compared to the plane tip. In this study, the tip surface is divided into six different regions, and transport phenomena at each region are discussed in detail. The mean thermal load averaged over the squealer cavity floor is augmented by 7.5 percents under the high inlet turbulence level.

입사각 변화에 따른 터빈 블레이드에서의 열전달 특성 변화 (II) - 블레이드 표면 - (Effect of Incidence Angle on Turbine Blade Heat Transfer Characteristics (II) - Blade Surface -)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제31권4호
    • /
    • pp.357-366
    • /
    • 2007
  • The present study investigated local heat/mass transfer characteristics on the surface of the rotating turbine blade with various incidence angles. The experiments are conducted in a low speed annular cascade with a single stage turbine. The blade has a flat tip with the mean tip clearance of 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. At design condition, the inlet Reynolds number is $Re_c=1.5{\times}10^5$ which results in the blade rotation speed of 255.8 rpm. Also, the effect of off-design condition is examined with various incidence angles between $-15^{\circ}$ and $+7{\circ}$. The results indicated that the incidence angle has significant effects on the blade surface heat transfer. In mid-span region, the laminar separation region on the pressure side is reduced and the laminar flow region on the suction side shrinks with increasing incidence angle. Near the tip, the effect of tip leakage flow increases in span wise and axial directions as the incidence angle decreases because the tip leakage flow is formed near the suction side surface. However, the effect of tip leakage flow is reduced with positive incidence angle.

청취자 거리정보가 필요 없는 도달각 기반 실내 위치 추정기법 (An Indoor Positioning Algorithm Based on 3 Points Near Field Angle-of-Arrival Estimation without Side Information)

  • 김영문;유승수;김선용
    • 한국통신학회논문지
    • /
    • 제35권11C호
    • /
    • pp.957-964
    • /
    • 2010
  • 본 논문에서는 근접장 (near field) 실내측위환경에 적합한 도움정보가 필요 없는 도달각 기반 위치추정기법을 제안한다. 기존 도달각 기반 실내 위치추정기법은 청취자와 마이크 사이의 거리정보를 청취자와 마이크사이의 수신신호세기로 추정하고 이와 측정된 신호의 도달시간차를 이용해 위치를 추정한다. 하지만 수신선호세기는 실내구조 및 가구배치나 신호의 특성에 따라 많은 영향을 받으며, 이는 도달각 추정에 큰 오차를 야기한다. 본 논문에서는 청취자 거리정보 없이 위치를 알고 있는 3개 이상의 마이크에서 수신한 신호의 도달지연시간차이에 기반한 도달각 기반 위치추정기법을 제안하고, 그 성능을 근평균제곱오차의 누적분포함수로 보인다.

Effects of Combustor-Level High Inlet Turbulence on the Endwall Flow and Heat/Mass Transfer of a High-Turning Turbine Rotor Cascade

  • Lee, Sang-Woo;Jun, Sang-Bae;Park, Byung-Kyu;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1435-1450
    • /
    • 2004
  • Experimental data are presented which describe the effects of a combustor-level high free-stream turbulence on the near-wall flow structure and heat/mass transfer on the endwall of a linear high-turning turbine rotor cascade. The end wall flow structure is visualized by employing the partial- and total-coverage oil-film technique, and heat/mass transfer rate is measured by the naphthalene sublimation method. A turbulence generator is designed to provide a highly-turbulent flow which has free-stream turbulence intensity and integral length scale of 14.7% and 80mm, respectively, at the cascade entrance. The surface flow visualizations show that the high free-stream turbulence has little effect on the attachment line, but alters the separation line noticeably. Under high free-stream turbulence, the incoming near-wall flow upstream of the adjacent separation lines collides more obliquely with the suction surface. A weaker lift-up force arising from this more oblique collision results in the narrower suction-side corner vortex area in the high turbulence case. The high free-stream turbulence enhances the heat/mass transfer in the central area of the turbine passage, but only a slight augmentation is found in the end wall regions adjacent to the leading and trailing edges. Therefore, the high free-stream turbulence makes the end wall heat load more uniform. It is also observed that the heat/mass transfers along the locus of the pressure-side leg of the leading-edge horseshoe vortex and along the suction-side corner are influenced most strongly by the high free-stream turbulence. In this study, the end wall surface is classified into seven different regions based on the local heat/mass transfer distribution, and the effects of the high free-stream turbulence on the local heat/mass transfer in each region are discussed in detail.

Can Right-Handed Surgeons Insert Upper Thoracic Pedicle Screws in much Comfortable Position? Right-Handedness Problem on the Left Side

  • Akyoldas, Goktug;Senturk, Salim;Yaman, Onur;Ozdemir, Nail;Acaroglu, Emre
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.568-573
    • /
    • 2018
  • Objective : Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. Methods : We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1-6) with classical position (anesthesiologist and monitor were placed near to patient's head. Surgeons were standing classically near to patient's body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient's belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1-2 mm penetration, 2-4 mm penetration and >4 mm penetration. Results : Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). Conclusion : Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon's position standing near to patient's head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.

강자성 배관 외.내부 벽의 racetrack형 결함깊이와 부피응력이 누설자속에 미치는 영향 (Effect of Racetrack Pit Depth and Bulk Stress on Far and Near-side Magnetic Flux Leakage at Ferromagnetic Pipeline)

  • 유권상;박영태;손대락
    • 한국자기학회지
    • /
    • 제13권2호
    • /
    • pp.70-75
    • /
    • 2003
  • 비선형 자기이방성 물질을 이용하여 3차원 유한요소법으로 강자성 배관 벽에 형성된 결함 근처에서 누설되는 자속에 미치는 부피인장응력(bulk tensile stress) 및 수직 응력의 영향을 계산할 수 있다. 배관의 외$.$내부 벽의 racetrack형 결함(racetrack pit) 깊이와 계산된 부피응력 (bulk stress)이 축(x) 방향, 원주(y) 방향 및 방사상(z) 방향의 누설자속에 미치는 영향을 계산하였다. 그 결과 배관의 축 및 방사상 방향의 MFL 신호는 배관 외$.$내부 면의 racetrack 결함깊이와 부피인장응력에 의해 영향을 받으며, 결함의 깊이가 깊어질수록 부피인장응력이 커질수록 MFL 신호는 증가하였다. 그러나 원주 방향의 MFL 신호는 결함깊이와 부피인장응력에 거의 영향을 받지 않았다.

이동표적 탐지를 위한 77 GHz 차량레이더용 가상배열 설계 (A Virtual Array Design of 77 GHz Vehicle Radar for Detecting Moving Targets)

  • 김두수;홍동희;주정명;양진모;이상인
    • 한국전자파학회논문지
    • /
    • 제26권5호
    • /
    • pp.435-444
    • /
    • 2015
  • 본 논문에서는 시분할 송신과 근거리에서 이동표적 탐지가 가능한 77 GHz 차량레이더용 가상배열 구조 설계에 대해 다루었다. 본 논문에서 기술된 가상배열 구조는 하드웨어의 복잡도, 무게 및 비용 등을 줄일 수 있는 반면, 시분할 송신에 의해 이동표적 탐지 시 수신신호의 위상왜곡으로 안테나 빔의 부엽이 높게 형성된다. 이를 위해 위상이 동일한 부배열 수신신호를 이용하여 안테나 빔의 부엽을 최소 10 dB 이상 억압시켰다. 또한, 근거리에서도 운용되어야 하는 차량레이더는 구면파 형태로 신호가 형성되어 평면파를 가정하는 빔 형성을 통해서는 빔 왜곡이 발생한다. 이를 위해 각 표적거리에 대해 관심 빔 조향 영역($-30^{\circ}{\sim}+30^{\circ}$)의 중심이 되는 정면 방향(${\phi}_{com}=0^{\circ}$)의 신호를 각 수신신호에 보정하여 안테나 빔의 왜곡된 주엽 형태를 회복시키고, 10~15 dB 정도 부엽 성능을 개선하였다.

Diurnal Variation of Atomospheric Pollutant Concentrations Affected by Development of Windstorms along the Lee Side of Coastal Mountain Area

  • Choi, Hyo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제24권1호
    • /
    • pp.29-45
    • /
    • 1996
  • Before (March 26, 1994) or after the occurrence of a downslope windstorm (March 29), the NO, $NO_2$, and $SO_2$ at the ground level of Kangnung city were monitored with high concentrations in the afternoon, due to a large amount of gases emitted from combustion of motor vehicle and heating apparatus, especially near 1600-1800 LST and 2000-2100 LST, but at night, they had low concentrations, resulting from small consumptions of vehicle and heating fuels. When both moderate westerly synoptic-scale winds flow over Mt. Taegwallyang and easterly meso-scale sea breeze during the day, atmospheric pollutants should be trapped by two different wind systems, resulting in higher concentration at Kangnung city in the afternoon. At night, the association of westerly synoptic wind and land breeze can produce relatively strong winds and the dissipation by the winds cause these low concentrations to lower and lower, as nightime goes on. From March 27 through 28, an enforced localized windstorm could be produced along the lee side of the mountain near Kangnung, generating westerly internal gravity waves with hydraulic jump motions. Sea breeze toward inland appartantly confines to the bottom of the eastern side of the mountain, due to the interruption of eastward violent internal gravity waves. As the windstorm moves down toward the ground, an encountering point of two opposite winds approaches Kangnung, and a great amount of NO and $NO_2$ were removed by the strong surface winds. Thus, their maximum concentrations are found to be near 18 and 20 LST, 17 and 21 LST. In the nighttime, the more developed storm should produce very strong surface winds and the NO and $NO_2$ could be easily dissipated into other place. The $SO_2$ concentration had no maximum value, that is, almost constant one all day long, due to its removal by the strong surface winds. Especially, the CO concentrations were slightly lower during the strom period than both before or after the strom, but they were nearly constant without much changes during the during the daytime and nighttime.

  • PDF

강자성 배관 외.내부 면의 단일 원형 홈의 깊이와 부피응력이 누설자속에 미치는 영향 (Effect of Ear and Near-side Single Circular Pit Depth and Bulk Stress on Magnetic Flux Leakage at ferromagnetic Pipeline)

  • 유권상;박영태
    • 비파괴검사학회지
    • /
    • 제23권3호
    • /
    • pp.263-269
    • /
    • 2003
  • 누설자속 (magnetic flux leakage: MFL) 신호는 매설된 송유관이나 가스관에 생성된 부식결함의 검사에 이용된다. 배관의 외 내부 면의 단일 원형 홈 (pit) 깊이와 부피응력 (bulk stress)이 축 (x) 방향, 원주 (y) 방향 및 방사상 (z) 방향의 누설자속에 미치는 영향을 3차원 유한요소법을 이용하여 계산하였다. 자기이방성 물질을 이용하여 부피인장응력 (bulk tensile stress)과 수직 응력에 의한 MFL 신호변화를 계산하였다. 배관의 축 및 방사상 방향의 MFL 신호는 배관 외 내부 면의 결함 길이가 깊어질수록, 부피인장응력이 커질수록 MFL 신호는 증가하였다 그러나 원주 방향의 MFL 신호는 결함 깊이와 부피인장응력에 영향을 거의 받지 않았다.

Skirt 제작에 관한 인간공학적 연구 -앉는 동작을 중심으로- (A Study on Making Skirt from the standpoints of Human Engineering)

  • 이년순
    • 대한가정학회지
    • /
    • 제18권4호
    • /
    • pp.31-39
    • /
    • 1980
  • The basic pattern of skirt should be functional in addition to be fit the body. The author paid special attention to the expansion and contraction of the shell which were made the lower trunk and thigh caused by sitting motions. The replicas of the shell were taken by using a gypsum method on 1 female under 4 standardized motions; standing motion, (basic motion), sitting on the chair with flextion 90' at the hip and the knee joints sitting with dropping knees, and sitting with benting legs side wards. Those replicas obtained were developed to the patterns and changes in shape and area of those were measured. Typical displacement and transformation of the shell surface patterns were showed geographycally fig 5-1 to 5-4. mean values of expansion and constriction were obtained by measuring the shell surface on 60 female under the 4 motions. the mean values of it were showed numerically in Table 1-1 to 1-3. The following results were obtained; 1. Vertical constriction of front of the shell were observed near sulcus in guinalis, and vertical extension were near the knees. Horizontal extension were observed near the thighs and the knees. 2. Vertical constrictions of the back of the shell were observed near the knees. It seemed to be influnced the flexion angles of knee points. vertical extension were near gluteus and thighs. Horizontal constriction were small, and horizonlal extension were near gluteus. 3. The high rates of constriction and extension were found near sulcus in guinalis, glutes, and knees. 4. The rates of constriction and extension on the waist line were very low. 5. The highest values of constriction and extension were found in hip and knees.

  • PDF