• Title/Summary/Keyword: Nd:YAG laser

Search Result 1,019, Processing Time 0.03 seconds

INHIBITORY EFFECT OF DENTAL LASERS ON THE GROWTH AND THE FUNCTION OF STREPTOCOCCUS MUTANS (각종 치과레이저의 Streptococcus mutans에 대한 증식 및 기능억제 효과)

  • Han, Kang-Seog;Kook, Joong-Ki;You, So-Young;Kim, Hwa-Sook;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.439-447
    • /
    • 2003
  • This was performed to evaluate the inhibitory effect of laser on the growth of S. mutans. The bacterial pallets containing S. mutans KCTC 3065 were irradiated with Er:YAG laser and Nd :YAG laser by non-contact method at an intensity of 50mJ for 5 sec with the pulse repetition rates of 10Hz and 30Hz, respectively. The following results were obtained on colony count, acid producing ability, and the amount of insoluble extracellular polysaccharide synthesis. 1. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the proliferation of S. mutans the most, and the irradiation of Er:YAG also inhibited the proliferation. However, the irradiation of Nd:YAG laser alone could not inhibited the proliferation of S. mutans. The pulse repetition rate did not affect significantly on the proliferation of bacteria in overall. 2. The irradiation of Nd:YAG laser after the photosensitization with Chinese ink inhibited the acid production of S. mutans the most for a certain period of time. Er:YAG laser also inhibited acid production. When Nd:YAG laser was used alone, the acid production of S. mutans was not been inhibited. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the acid production ability of bacteria the most as the pulse repetition rate increased. 3. Laser irradiation did not inhibited the synthesis of insoluble extracellular polysaccharide of S. mutans. From these results, we conclude that the irradiation of Er:YAG laser and Nd:YAG laser after photosensitization with Chinese ink would inhibit the proliferation and acid production by S. mutans, which may prevent dental caries. However, this effect does not last long time so that the laser irradiation should be repeated frequently in order to obtain clinical effect; thus, this laser irradiation would not have a clinical usefulness in preventing dental caries when used solely.

  • PDF

A Study on the Butt Welding of Zircaloyf Sheets Using Nd:YAG Laser (Nd-YAG 레이저를 이용한 Zircaloy-4 판재의 맞대기 용접에 관한 연구)

  • 황용화;고진현
    • Proceedings of the KWS Conference
    • /
    • 2000.04a
    • /
    • pp.139-143
    • /
    • 2000
  • Laser beam weldability of Zircaloy-4 was investigated using a pulsed Nd:YAG laser of 550W average power. Mechanical properties and microstructure of laser butt welded Zircaloy-4 test specimens were examined. The influence of laser generated during laser welding was analyzed and optimum laser welding parameters were investigated.

  • PDF

Development of a pulsed Nd:YAG laser materials processing system (정밀 용접용 펄스형 Nd:YAG 레이저 가공기 개발)

  • 김덕현;정진만;김철중;이종민
    • Journal of Welding and Joining
    • /
    • v.9 no.1
    • /
    • pp.32-39
    • /
    • 1991
  • A 200W pulsed Nd: YAG laser for fine welding was developed. The important laser parameters such as laser peak power, average power, pulse width, and pulse energy for welding were studied. In order to obtain the sufficient laser power density for welding, thermal lensing effects were analyzed and a laser resonator with laser beam divergence was designed. The power supply unit was designed to support up to 7kW input. The pulse control unit was developed using a GTO thyristor and could control over 100kW input power to obtain 3.5kW peak power laser. Also due to the GTO thyristor the pulse width could be varied continuously from 0.1 to 20 msec and maximum repetition rate was as high as 300pps.

  • PDF

Absorption Characteristics of Amorphous Metal during Processing with Nd:YAG laser (Nd:YAG 레이저를 이용한 비결정질 재료의 용접 시 레이저의 흡수 거동)

  • 이건상
    • Laser Solutions
    • /
    • v.2 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • For the conventional welding method. the high heat transfer makes the crystallized zone of the work material unavoidable. Whereas the laser is able to weld the amorphous metal without a crystallized zone, because heat transfer is limited within a very small restricted volume. In this paper, the possibilities and the limits of the laser welding were studied to utilize the advantageous properties of amorphous metal foils.

  • PDF

Finite element analysis for prediction of bead shape of Nd:YAG laser butt welding (Nd:YAG 레이저 맞대기 용접의 비드형상 예측에 관한 유한요소해석)

  • Kim, Kwan-Woo;Nam, Gi-Jeong;Lee, Jae-Hoon;Suh, Jeong;Cho, Hae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.137-146
    • /
    • 2008
  • Nd:YAG pulse laser welding of stainless steel plate was simulated to find welding condition by using commercial finite element code MARC. Due to geometric symmetry, a half model of AISI 304 stainless steel plate was considered and user subroutines were applied to boundary condition for the heat transfer. Material properties such as conductivity, specific heat, mass density and latent heat were given as a function of temperature. As results, Three dimensional heat source model for pulse laser beam conditions of butt welding has been designed by the comparison between the finite element analysis results and experimental data on AISI 304 stainless steel plate. Nd:YAG laser welding for AISI 304 stainless steel was successfully simulated and it should be useful to determine optimal welding condition.

Effect of Nd:YAG Laser Irradiation to Mental Region for Sensory Nerve Conduction Change (하악 이공부에 조사된 Nd:YAG 레이저가 감각신경전도변화에 미치는 영향)

  • Jeon, Jae-Woo;Kim, Kyoung-Hee;Ko, Myong-Yun;Ahn, Yong-Woo;Park, Jun-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.447-455
    • /
    • 2005
  • The purpose of this study was to examine the effect of Nd:YAG laser irradiation for sensory nerve conduction change. Nd:YAG laser was irradiated to mental region for 5 minutes with the parameters that 10 Hz and 20 Hz of 100 mJ/pulse. Target size of irradiation was 30 mm diameter of circle and target-tip distance was about 10 mm. Therefore, the power density were 212 $mW/cm^2$ and 424 $mW/cm^2$. Sensory nerve conduction was evaluated with $Neurometer^{\circled}$ CPT/C before and after Nd:YAG laser irradiation. As an outcomes, the current perception threshold(CPT) and pain tolerance threshold(PTT) were obtained. We made a comparison of these two values and the results were as follows. 1. There was no significant difference in CPT at 1W, 10 Hz and 2 W, 20 Hz Nd:YAG laser irradiation. 2. There was no significant difference in PTT at 10 Hz, 20 Hz of 100 mJ/pulse Nd:YAG laser. 3. There were no significant differences in CPT and PTT between 1 W, 10 Hz group and 2 W, 20 Hz group. Therefore, We can make a conclusion that Nd:YAG laser irradiation to mental region have no effect on mental nerve conduction in our study model.

Analysis of Crack Behavior in a Ceramic Nd:YAG (세라믹 Nd:YAG 레이저 매질의 균열 해석)

  • Kim, Duck-Lae;Kim, Byung-Tai
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.186-186
    • /
    • 2010
  • The crack behavior in the ceramic Nd:YAG at a laser-diode end-pumped Nd:YAG ceramic laser was investigated. The fracture critical temperature difference of the ceramic Nd:YAG is about $355^{\circ}C$. The fracture of the 2 at% and the 4 at.% ceramic Nd:YAG occurred more than 14.9 W and 6.9 W pump powers, respectively, under lasing conditions.

  • PDF

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

Laser Diode Pumped Mode-Locked $1.3{\mu}m$ Nd-YAG Laser (모드록킹된 다이오드 여기 $1.3{\mu}m$ Nd:YAG 레이저)

  • Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.271-274
    • /
    • 2007
  • 본 연구는 $1.3{\mu}m$ 파장의 초고속 Nd:YAG레이저 펄스를 얻기 위해 AOM을 이용하여 모드록킹 Nd:YAG레이저 공진기를 구성하였다. 여기용 반도체 레이저는 중심파장 810nm, 출력 1.2W이며, 레이저 매질은 직경 3mm, 길이 10mm로 $Nd^{3+}$가 1.0at%로 도핑된 Nd:YAG Rod를 사용하였다. 모드록킹에는 음향광학 변조기(변조 주파수 40MHz)를 사용하여 펄스폭 ${\tau}p=80ps$의 극초단 펄스를 얻었다.

  • PDF

Thermal effect at Nd:YAG using a laser-diode side-pumping (반도체 레이저 측면 여기 Nd:YAG 매질에서의 열영향)

  • 양동옥;김병태
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.44-50
    • /
    • 2003
  • This paper describes the thermal effect at Nd:YAG using a laser-diode side-pumping. To detect the depolarization loss and the retardation caused by the thermal effect, a λ/4 plate is inserted between the polarizer and the Nd:YAG laser material. Using a CCD has allowed detection of the variation of the beam pattern that could analyze the change of the refractive index of the Nd:YAG laser material by the thermal effect. Through the change of the probe beam power, we know that 21% of the pumping power was converted into heat in the material. The depolarization loss was 24.7% under a temperature of $25^{\circ}C$ of the laser material and a pumping power of 15 W. The inhomogeneous distribution showed that the retardation angle was 7$^{\circ}$ in the center of the material and 19$^{\circ}$ on the edge of it. It is confirmed that the thermal effect is analyzed at the each point of the laser material and it suggests an effective method to reduce the thermal effect on the LD side-pumped laser material.