• Title/Summary/Keyword: Natural velocity

Search Result 1,024, Processing Time 0.028 seconds

A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

Vibration Analysis of Three-Dimensional Piping System by Transfer Matrix Method (전달행렬법을 이용한 3차원 파이프 계의 진동해석)

  • 이동명
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.110-116
    • /
    • 1998
  • For the vibration analysis of 3-dimensional piping system containing fluid flow, a transfer matrix method is presented. The fluid velocity and pressure were considered, that coupled to longitudinal and flexural vibrations. Transfer matrices and point matrices were derived from direct solutions of the differential equations of motion of pipe conveying fluids, and the variations of natural frequency with flow velocity for 3-dimensional piping system were investigated.

  • PDF

Flow Field Measurement of Natural Convection in a Rectangular Cavity Using Laser Speckle Photography (레이저 반점(斑點)을 이용한 사각형(四角形) 공동(空洞)내의 자연대류(自然對流) 유동장(流動場) 측정(測定))

  • Yang, Soong-Hyo;Chung, Woo-Nam;Park, Chan-Kuk;Kang, Yung-Kyu
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 1989
  • A two-dimensional velocity map of natural convection in a rectangular cavity is determined using laser speckle photography. Isovelocity contour drawn by spatial filtering and local velocity by pointwise method are obtained. These results are compared with those of numerical analysis.

  • PDF

Comparison of the Vertical Velocity Distribution in the Natural Streamflow (자연하천의 연직방향 유속분포 비교(수공))

  • 박승기;김태철
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.346-351
    • /
    • 2000
  • The study was carried out to investigate the characteristics of vertical velocity distribution measured by current meter at Kangkyung station in Keum river during the period of 1995 to 1997. It suggests the quadratic parabola equation to estimate the vertical velocity profile only from the measurement data of surface velocity. The equation was found to be statistically very stable and showed high significance to express the surface velocity and bottom velocity. The vertical velocity profile was determined by the relationships to the surface velocity, and a coefficient of the quadratic parabola equation. The vertical velocity profile can be applied to calculating the mean velocity and discharge, and to and to analyse the dispersion of pollutant materials in the streamflow.

  • PDF

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Improvement of Natural Ventilation in a Factory Building Using PIV Technique (PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구)

  • Kang Jong-Hoon;Lee Snag-Jeon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

An Experimental Study on the Measurement of Radial Directional Natural Frequency in a Passenger Car Tire Roboting under the Load (하중을 받고 회전하는 승용차 타이어의 반경방향 고규진동수 측정에 관한 실험적 연구)

  • Kim, Byoung-Sam;Hong, Dong-Pyo;Chi, Chang-Heon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.1
    • /
    • pp.1-13
    • /
    • 1996
  • The measurement of radial directional natural frequency ina passenger car tire rotating under the load is studied. In order to obtain theoretical matural frequency and mode shape, the ploane vibration of a tire is modeled to that of circular beam. By esing the Tieking method based on Hamiltons's principle, theoretical results are determined by considering tension horce due to tire inflation pressure, retational velocity and tangential, radial stiffness. Radial directional modal parameters varying with the inflation pressure, load, rotational velocity are experimentally determined by using frequency response function method. The results show that experimental conditions canbe considered as the parameters which shift the natural frequency.

Study on the Thermodynamic Properties and Combustion Information of Natural Gases from Various Producing Districts (산지별 천연가스들의 열 물성치 및 연소 정보 검토)

  • Lee, Chang-Eon;Hyun, Seung-Ho;Hwang, Cheol-Hong;Lee, Sung-Min;Ha, Young-Cheol;Lee, Kang-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.1
    • /
    • pp.38-47
    • /
    • 2007
  • The diversification of import districts of natural gas is trying to prepare an increase in the demand and price. The interchangeability of natural gases should be examined prior to supply to gas appliances, although compositional differences among natural gases are not large. The object of this study is to investigate numerically the thermodynamic and transport properties as well as information on combustion of 6 natural gases. Comparing the properties of BOG1 with those of standard gas, the maximum differences of heating value, Wobbe index, air-fuel ratio, and specific heat are 10%, 4%, 10% and 5.54%, respectively. That is, the BOG1 is required careful application. However, all gases except for BOG1 show the similar properties with standard gas. Finally, the combustion information such as flame temperature and burning velocity are examined. These results will provide the useful information related to the interchangeability of various natural gases in practical combustion appliances.

  • PDF

An Investigation of the Fundamental Combustion Characteristics for the Utilization of LFG (LFG 활용을 위한 기초 연소특성 검토)

  • Lee, Chang-Eon;Oh, Chang-Bo;Kum, Sung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.99-108
    • /
    • 2004
  • Fundamental combustion characteristics, such as the combustion potential, burning velocity and flame stability, for the practical utilization of LFG(Landfill gas) and LFG-blended fuels were experimentally investigated. The combustion potentials(CP) of LFG-blended fuels calculated from the previously suggested formulae were compared with burning velocities obtained by present experiments. The results showed that the previous formulae fur CP of LFG-blended fuels were not agreed with the experimental burning velocity, and these formulae should be revised. To provide an useful information needed to design the combustion devices, a triangular diagram was suggested for the maximum burning velocity of the mixture of CH$_4$, LPG and LFG. From the investigation of the burning velocity and the flame stability in a practical combustor, it was noted that the LFG-blended fuels, of which heating values or Wobbe indices were adjusted to that of natural gas, could be used as an alternative fuel of natural gas.

Numerical Simulation of Vertical Wall Fires I. Turbulent Natural Convection Along Vertical Wall (수직벽화재의 수치 시뮬레이션 I. 수직벽 난류자연대류)

  • Park, Woe-Chul;Trouve, Arnaud
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.181-187
    • /
    • 2008
  • Numerical simulation of natural convection along a vertical wall was carried out to evaluate the computational fluid dynamics simulator, which is to be utilized for study of vertical wall fires. The computed velocity and temperature profiles were compared with measurements over the turbulent boundary layer formed along the wall of 4m high and constant temperature. It fumed out that the simulator with default parameters failed to predict the turbulent natural convection showing the boundary layer flow laminar. The grid size $\Delta$x=5mm, ${\Delta}y={\Delta}z=10mm$ and Smagorinsky constant of the large eddy simulation $C_s$=0.1 were chosen through parametric investigations. Though turbulent mixing was not enough, the velocity distribution near wall, peak velocity, and temperature profile in the turbulent boundary layer agreed well with the measurements.