• 제목/요약/키워드: Natural Shedding

검색결과 89건 처리시간 0.031초

진동하는 원주주위 유동의 직접수치해석 (Direct Numerical Simulation of the Flow Past an Oscillating Circular Cylinder)

  • 강신정;;;남청도;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 춘계 학술대회논문집
    • /
    • pp.181-188
    • /
    • 2001
  • The flow past a circular cylinder forced to vibrate transversely is numerically simulated by solving the two-dimensional Wavier-Stokes equations modified by the vibration velocity of a circular cylinder at a Reynolds number of 164. The higher-order finite difference scheme is employed for the spatial discretization along with the second order Adams-Bashforth and the first order backward-Euler time integration. The calculated cylinder vibration frequency is between 0.60 and 1.30 times of the natural vortex-shedding frequency. The calculated oscillation amplitude extends to $25\%$ of the cylinder diameter and in the case of the lock-in region it is $60\%$. It is made clear that the cylinder oscillation has influence on the wake pattern, the time histories of the drag and lift forces, power spectral density and phase diagrams, etc. It is found that these results include both the periodic (lock-in) and the quasi-periodic (non-lock-in) state. The vortex shedding frequency equals the driving frequency in the lock-in region but is independent in the non-lock-in region. The mean drag and the maximum lift coefficient increase with the increase of the forcing amplitude in the lock-in state. The lock-in boundaries are also established from the present direct numerical simulation.

  • PDF

보일러 튜브군의 음향공진 회피를 위한 음향배플의 위치에 따른 FEM 음향모드해석 (FEM acoustic modal analysis due to location of acoustic baffles to avoid acoustic resonance in the tube bank of boiler for power plant)

  • 안성종;주영호;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.150-154
    • /
    • 2012
  • A flow induced mechanical vibration and acoustic resonance should be considered at design stage because they are mainly occurred in the tube bank of boiler. Acoustic resonance is occurred when the vortex shedding frequency of tube bank coincides with the acoustic natural frequency of the cavity. Effective solution to avoid acoustic resonance is installing acoustic baffles in the tube banks parallelly inside of the flow cavity. Thus, location and number of acoustic baffles should be exactly calculated to eliminate the acoustic resonance. This paper presents case study of acoustic resonance due to inappropriate number and location of acoustic baffles. Measured frequency and mode in the study is verified by FEM acoustic modal analysis. The number and location of acoustic baffles to avoid acoustic resonance are calculated by using FEM acoustic modal analysis.

  • PDF

전단류 하중을 받는 상부장력 라이저의 동적 응답 해석 (Dynamic Response Analysis of Top-tensioned Riser Under Sheared Current Load)

  • 김국현
    • 한국해양공학회지
    • /
    • 제27권4호
    • /
    • pp.83-89
    • /
    • 2013
  • A numerical scheme based on a mode superposition method is presented for the dynamic response analysis of a top-tensioned riser (TTR) under sheared current loads. The natural frequencies and mode shapes of the TTR have been calculated analytically for a beam with a slowly varying tension and pinned-pinned boundary conditions at the top and bottom ends. The lift coefficients and corresponding amplitudes used to estimate the vortex-induced modal force and damping for each mode were predicted via iterative calculations based on the input and output power balancing concept. Here, the power-in regions were controlled by the normal distribution function, for which the center was coincident with the lock -in location by local vortex-shedding, and the range was defined by the constant standard deviation for the reduced velocity by the local current speed. Finally, dynamic responses such as root-mean-squared displacement and stress were calculated using the mode superposition technique. In order to verify the presented scheme, a numerical calculation was performed for a TTR under an arbitrary linearly sheared current and linearly varying tension. A comparison with the results of the existing software showed that the presented scheme could give reliable and feasible solutions. Case studies were performed to investigate the effects of various current loads and tensions.

진동하는 구 주위의 유동에 관한 수치적 연구 (Numerical Study of Flow Around an Oscillating Sphere)

  • 이진욱;이대성;하만영;윤현식
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.767-772
    • /
    • 2010
  • The incompressible viscous flow past a sphere under forced oscillation is numerically investigated at a Reynolds number of 300. The immersed boundary method is used to handle the sphere oscillating vertically to the streamwise direction. There are two important variables to characterize the oscillating state of a sphere. One is an oscillating amplitude normalized by the sphere diameter is set as a fixed number of 0.2. Another is the frequency ratio which is defined by $f_e/f_o$, where fe and fo are the excited frequency and the natural frequency of vortex shedding for the stationary sphere. In this study, three different frequency ratios of 0.8, 1.0 and 1.2 are considered. The results show a periodic flow with hairpin vortices shedding from upper and lower positions as well as vortical legs obliquely extended by oscillating motion of sphere. The enveloping vortical structure experience rupture twice in one period of oscillation. As the frequency of oscillation is increased, the vortical legs are getting shorter and eventually the hairpin vortices are much closer to the adjacent one.

중공부(中空部)를 가진 고층건축물(高層建築物)의 풍응답(風應答) 특성(特性)에 관한 풍동실험(風洞實驗) 연구(硏究) (Wind Tunnel Test Study on the Characteristics of Wind-Induced Responses of Tall Buildings with Openings)

  • 김동우;길용식;하영철
    • 한국강구조학회 논문집
    • /
    • 제17권4호통권77호
    • /
    • pp.499-509
    • /
    • 2005
  • 강풍으로 유발되는 고층건축물의 풍진동은 주로 와류에 의한 풍직각방향의 진동에 의하여 발생한다. 이러한 진동은 단면형상이 일정한 유연하고, 경량이며, 경감쇠인 고층건축물인 경우 가장 심하게 발생한다. 본 논문은 와류에 기인한 풍직각방향의 진동을 저감시키기 위한 공역학적인 방법을 논한 것이다. 항력 및 횡력방향의 압력을 균등화하고 또한 양방향의 공간적인 간섭을 분산시키고, 풍직각 방향으로 작용하는 풍력의 크기를 효율적으로 감소시키기 위하여 건축물의 풍방향 및 풍직각방향에 중공부를 설치하였다. 실험모형은 모두 형상비가 8:1이 되도록 하였고, 중공부의 형상은 2종류, 크기는 2종류, 위치는 6종류로 변화시킨 총 24종류의 모형을 제작하여 풍력실험을 실시한 후 각 모형에 대한 풍방향 및 풍직각방향의 변위응답특성을 조사하였다. 최종적으로 중공부를 가진 모형의 효율성을 분석하기 위하여 중공부를 가진 모형에 대한 결과를 중공부가 없는 정사각형 각주의 변위응답 특성과 비교 분석하여 중공부의 형상 변화, 크기 변화, 위치 변화에 따른 풍진동의 저감효과의 정도를 정량적으로 규명하였다.

남한강류역(南漢江流域)의 호르텐스극구흡충(棘口吸蟲) 감염실태(感染實態)와 생활사(生活史)에 관(關)한 연구(硏究) (Experimental and epidemiological studies on the life cycle of Echinostoma hortense Asada, 1926(Trematoda: Echinostomatidae))

  • 안영겸;양룡석
    • Parasites, Hosts and Diseases
    • /
    • 제24권2호
    • /
    • pp.121-136
    • /
    • 1986
  • Recently there have been some reports on human infections of Echinostoma hortense in Korea. It was found that a few species of freshwater fishes were playing the role of the second intermediate host of E. hortense. However, molluscan intermediate host has not been identified yet in Korea. The present study aimed to establish the life cycle of E. hortense in laboratory. Experimental studies such as egg production from the rat, development of the eggs in vitro, exposure of miracidia to freshwater snails, shedding pattern of cercariae from infected snails, morphology of cercariae, cercarial infection to the second intermediate host and infection of metacercariae to the definitive hosts were done. In addition, epidemiological surveys on the infection status in inhabitants and house rats, and on the natural infection of larval echinostomes in the snails and fishes were carried out along the South Hangang-river. The results obtained were as follows: 1. The eggs deposited from adults in physiological saline were cultivated at room temperature($20{\sim}24^{\circ}C$). The miracidia were firstly observed on 8 days after cultivation, and 85.5% of the eggs contained the mature miracidia on 11 days after cultivation. More than 90% formed the miracidia when cultivated at temperature $22{\sim}27^{\circ}C$. Hatching of the miracidia began on 12 days after cultivation and continued for a week. The size of the miracidia was $103.0{{\times}}51.4{\mu}m$ in average. The motility of the miracidia were active up to 8 hours after shedding, but they were all dead within 10 hours after shedding. 2. A freshwater snail, Radix auricularia coreana was cultivated in aquaria. A hatched $F_1$ snails from the egg masses were exposed to 20 miracidia respectively. Escape of cercariae started on 15 days after infecton. Radix auricularia coreana was experimentally identified as the first intermediate host of E. hortense in Korea. 3. Cercarial shedding started on $15{\sim}20$ days after infection by snail, continued for about 10 days (8.8 days in average). Infected snails were dead within 32 days after the miracidial infection. About 1,335 cercariae($328{\sim}1,994$) per snail were shed in its life, and 119 cercariae in average per snail per day were shed. The cercariae were motile for more than 24 hours, and then squirming at the bottom until death. The body and tail sizes of cercariae were $356{\times}186{\mu}m$ and $510{\times}68{\mu}m$ in average, respectively. The rediae parasitized in the snail hosts were found mainly around the pericardial regions, and their size was $1,575{\times}258{\mu}m$ in average. The numbers of developing cercariae in a mature redia were 14 in average ($7{\sim}20$ in range). The numbers of rediae in a snail were 102 in average on 15 days after miracidial infection and 221 in average on 28 days. 4. Three uninfected Misgurnus anguillicaudatus, less than 6.5cm long were used in for the cercarial infection. They were all exposed with 755 cercariae, and examined at 5-day intervals starting from 10 days after infection. All the fishes were infected with metacercariae of E. hortense and a total of 275 was found infected(36.4%). The metacercariae were fed to rats and the adult worms were obtained on 15 days after infection. 5. The infected rats began to deposit the eggs on 11 days after infection. The number of eggs deposited per day per worm (EPD/worm) was $400{\sim}500$ on 3 weeks after infection and was increased to $1,000{\sim}1,500$ on 4 to 17 weeks, then decreased to 800 on 21 weeks after infection. 6. A total of 745 stool specimens collected from 576 male and 169 female residents of 8 different villages along South Hangang basin was examined. Out of 745 specimens, the eggs of Echinostoma sp. were found in 2 cases (0.3%). Of 34 house rats one showed egg-positive (2.9%). 7. Total 971 Radix auricularia coreana collected from 7 sampling stations were examined for shedding of cercariae. Three snails (0.3%) shed the cercariae of E. hortense. A total of 119 out of 542 freshwater fishes (22.0%) had the metacercariae of E. hortense. The fishes parasitized with the metacercariae were 4 out of 14 examined species. The infection rates of 4 species were 34.1% (106 out of 311) in Misgurnus anguillicaudatus, 30.4% (7 out of 23) in Misgurnus mizolepis, 4.3% (2 out of 46) in Moroco oxycephalus and 22.2% (4 out of 18) in Odontobutis obscura interrupta. In summarizing the above results, the first intermediate host of E. hortense was found as Radix auricularia coreana in Korea. Also, it took about 46 days for the shortest completion of a life cycle of E. hortense in summer; that is, 10 days for miracidial development in eggs, 15 days for cercarial development in the snail, about 10 days for metacercarial development in the second intermediate hosts, and 11 days for the maturation as the adults in the definitive hosts. The natural infection rates of E. hortense in the intermediate hosts were relatively high but those in the definitive hosts were low in the middle areas of South Hangang basin.

  • PDF

Vorinostat-induced acetylation of RUNX3 reshapes transcriptional profile through long-range enhancer-promoter interactions in natural killer cells

  • Eun-Chong Lee;Kyungwoo Kim;Woong-Jae Jung;Hyoung-Pyo Kim
    • BMB Reports
    • /
    • 제56권7호
    • /
    • pp.398-403
    • /
    • 2023
  • Natural killer (NK) cells are an essential part of the innate immune system that helps control infections and tumors. Recent studies have shown that Vorinostat, a histone deacetylase (HDAC) inhibitor, can cause significant changes in gene expression and signaling pathways in NK cells. Since gene expression in eukaryotic cells is closely linked to the complex three-dimensional (3D) chromatin architecture, an integrative analysis of the transcriptome, histone profiling, chromatin accessibility, and 3D genome organization is needed to gain a more comprehensive understanding of how Vorinostat impacts transcription regulation of NK cells from a chromatin-based perspective. The results demonstrate that Vorinostat treatment reprograms the enhancer landscapes of the human NK-92 NK cell line while overall 3D genome organization remains largely stable. Moreover, we identified that the Vorinostat-induced RUNX3 acetylation is linked to the increased enhancer activity, leading to elevated expression of immune response-related genes via long-range enhancer-promoter chromatin interactions. In summary, these findings have important implications in the development of new therapies for cancer and immune-related diseases by shedding light on the mechanisms underlying Vorinostat's impact on transcriptional regulation in NK cells within the context of 3D enhancer network.

발전용 보일러 후부 전열면 소음진동 저감에 관한 연구 (A Case Study on the Reduction of Noise and Vibration at the Backpass Heat Surface in the Power Plant Boiler)

  • 이경순;이태구;문승재;이재헌
    • 플랜트 저널
    • /
    • 제4권3호
    • /
    • pp.54-59
    • /
    • 2008
  • The resonance of boiler is caused by exciting force in the gas path and it generates the vibration by the harmony of boiler's dimensional factor. According to trending toward the boiler of increasing capacity and a bigger size, it has a problem of the vibration at back-pass heating surfaces. We can predict such vibrations as comparison between vortex frequency and gas column's natural frequency. We can't rely on the method for the past decades because of changing parameters, such as an allowable error, gas temperature, gas velocity, Strouhal number. We can reduce the vibration to use the seasoning effect and change the operating condition in coal fired boiler but it's not essential solution. When the vibration occurred in the model boiler, we must measures the acoustic pressure and frequency of places for considering the means. So far, we confirmed the problem from field measures and theoretical analysis about the acoustic vibration of boiler. We installed anti-acoustic baffle in a existing boiler to change the acoustic natural frequency at the cavity, which results in reducing the acoustic vibration. The first, we prove that the acoustic resonance is caused by harmonizing vortex shedding frequency of tube heat surface with acoustic natural frequency of cavity in the range of 650~750 MW loads. The second, the acoustic resonance at the back-pass heating surface has the third order of acoustic natural frequency at the second economizer. We install five anti-acoustic baffles at the second economizer to reducing the resonance. We confirm considerably reducing the acoustic vibration of boiler during the commercial boiler.

  • PDF

주기적으로 회전진동하는 원주 후류의 유동구조에 관한 실험적 연구 (Experimental Study on Flow Structure of Wake Behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.298-305
    • /
    • 2006
  • The flow around a circular cylinder which oscillates rotationally with a relatively high forcing frequency has been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), oscillation amplitude $({\theta}_A)$, and frequency ratio $F_R=f_f/f_n$, where $f_f$ is the forcing frequency and $f_n$ is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\theta}_A={\pi}/6$, and $0{\leq}F_R{\leq}2$. The effect of frequency ratio $F_R$ on the flow structure of wake was evaluated by measuring wake velocity profile and spectral analysis of hot-wire signal. Depending on the frequency ratio $F_R$, the cylinder wake has 5 different flow regimes. The vortex formation length and vortex shedding frequency are changed significantly before and after the lock-on regime. The drag coefficient was reduced under the condition of $F_R<1.0$ and the maximum drag reduction is about 33% at $F_R=0.8$. However, the drag is increased as $F_R$ increases beyond $F_R=1.0$. This active flow control method can be effective in aerodynamic applications, if the forcing parameters are selected optimally.

Mechanism on suppression in vortex-induced vibration of bridge deck with long projecting slab with countermeasures

  • Zhou, Zhiyong;Yang, Ting;Ding, Quanshun;Ge, Yaojun
    • Wind and Structures
    • /
    • 제20권5호
    • /
    • pp.643-660
    • /
    • 2015
  • The wind tunnel test of large-scale sectional model and computational fluid dynamics (CFD) are employed for the purpose of studying the aerodynamic appendices and mechanism on suppression for the vortex-induced vibration (VIV). This paper takes the HongKong-Zhuhai-Macao Bridge as an example to conduct the wind tunnel test of large-scale sectional model. The results of wind tunnel test show that it is the crash barrier that induces the vertical VIV. CFD numerical simulation results show that the distance between the curb and crash barrier is not long enough to accelerate the flow velocity between them, resulting in an approximate stagnation region forming behind those two, where the continuous vortex-shedding occurs, giving rise to the vertical VIV in the end. According to the above, 3 types of wind fairing (trapezoidal, airfoil and smaller airfoil) are proposed to accelerate the flow velocity between the crash barrier and curb in order to avoid the continuous vortex-shedding. Both of the CFD numerical simulation and the velocity field measurement show that the flow velocity of all the measuring points in case of the section with airfoil wind fairing, can be increased greatly compared to the results of original section, and the energy is reduced considerably at the natural frequency, indicating that the wind fairing do accelerate the flow velocity behind the crash barrier. Wind tunnel tests in case of the sections with three different countermeasures mentioned above are conducted and the results compared with the original section show that all the three different countermeasures can be used to control VIV to varying degrees.